Help needed to find out the disk controller for veritas disks
hi all
i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output
My question is, i have ultrascsi storage box which is having 6 sun 36 GB hard disks. here for the root disk, it is straightaway giving the c#t#d#s# number. i am not getting for other disks. There is one command, i hope it is "vxddlam" with some option can give the exact controller and its respect disk names. Can someone tell me that command?
Hi,
I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below:
/pci@8,600000/SUNW,qlc@2
LiD HA LUN --- Port WWN --- ----- Disk description -----
0 0 0 ... (1 Reply)
recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
hi
this may be a very stupid question, but im quite new to Solaris (gonna buid my first system, Solaris 10 on x86 system, connected to other windows systems in a home network)
i wanna put a RAID 5 system in there to back up my other systems at home; iv read that its really so easy with SVM to... (4 Replies)
hi...
i hav a problem to install sco unix
while installing sco unix 5.0.5 in acer altos with hardware raid
am getting error
"Warning HD: no root disk controller was found
system error 5: while getting fs type
flushing controller: DAC960PRL cache done."
i hav use the following... (18 Replies)
So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller.
First, I downloaded the megasas driver from SCO and installed it on the old system.
Then I created a new Microlite Edge emergency boot cd with the new driver on it.
I... (2 Replies)
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all.
How shall I solve this problem? I am thinking of booting from... (2 Replies)
Hi
The scenario in the oracle t4-1 hardware with solaris 10 is as follows:
1. The initial install on the server was performed with an incorrect disk layout.
2. New disks were ordered and slot into the server.
3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Hi Experts,
I wanted to extend a veritas file system which is running on veritas cluster and mounted on node2 system.
#hastatus -sum
-- System State Frozen
A node1 running 0
A node2 running 0
-- Group State
-- Group System Probed ... (1 Reply)
Hi
I have created a new setup for VCS for doing some testing on virtual box. After creating 3 Solaris 10 machine (147148-26) with VCS. Here I have used one machine as ISCSI Storage.
VCS Version is
bash-3.2# /opt/VRTS/bin/haclus -value EngineVersion
6.0.10.0
bash-3.2#
bash-3.2# pkginfo... (4 Replies)
Discussion started by: hb00
4 Replies
LEARN ABOUT HPUX
pfto
pfto(7) Miscellaneous Information Manual pfto(7)NAME
pfto - Powerfail Timeout
DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time-
out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below).
If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt.
pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If
dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device.
The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands
display the current pfto value for a disk.
EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01:
vxdisk -g rootdg set disk01 pfto=30
Use either of the following commands to display the pfto value on the VxVM disk disk01:
vxdisk list disk01
vxprint -l disk01
EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error.
SEE ALSO vxdisk(1M), vxprint(1M)VxVM 5.0.31.1 24 Mar 2008 pfto(7)