Sponsored Content
Operating Systems Solaris Add new disk to Sun StorEdge 3310 RAID Post 302429735 by jamie_collins on Tuesday 15th of June 2010 10:47:32 AM
Old 06-15-2010
Add new disk to Sun StorEdge 3310 RAID

HI guys.
Bit of a noob so bear with me.

I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was good to partition the slices...

On our 3310 (RAID) I plugged them in and its not seeing them:

Code:
 
# format
Searching for disks...done
 
 
AVAILABLE DISK SELECTIONS:
       0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
          /pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000004cfd967a7,0
       1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
          /pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000004cfd964d1,0
       2. c2t0d0 <SUN-StorEdge3310-0325 cyl 35424 alt 2 hd 127 sec 127>
          /pci@8,600000/pci@1/scsi@4/sd@0,0

What steps do I need to perform to allow the server to see the 2 new added disks. (SEAGATES)

Thanks
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

sun storedge

I just installed sun storedge 3310 connected to a sunfire 280R with a total siz of 680GB and now am trying to create filesystems. issue format command and created my partitions, the largest size of the partition is 170GB. but I try to create new filesystems by using newfs like newfs... (3 Replies)
Discussion started by: hassan2
3 Replies

2. Solaris

Add new hard disk to sun sparc server?

A sparc server has a new SCSI hard disk added and labeled by the engineer, but they need to be formatted identically to an existing disk (c4t0d0). You decide to script the process and run from the command line without interaction. I know that the following command line must be achieve this. #... (3 Replies)
Discussion started by: kingsan
3 Replies

3. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

4. UNIX for Dummies Questions & Answers

Sun - RAID

From what I have been finding on the net is that most all Sun RAID setups are software? Is it really that uncommon for Sun servers to have hardware RAID? (6 Replies)
Discussion started by: kingdbag
6 Replies

5. Solaris

Using Enterprise 4500 with storedge D100 and storedge A5200

Sorry if this seems trivial. i have been given a task at work to configure a sun processing server "enterprise 4500" so it can work with the a storage server "storedge A5200" and "storedge D1000" the truth is i have never worked on a sun server before. i need a guideline (step by step) as to... (5 Replies)
Discussion started by: lawalidowu
5 Replies

6. Solaris

storEDGE A5000 disk Array

Do you know how do I make my solaris 8 detect the storEDGE A5000?. I have problem making it recognise, without that I cannot install VxVM. Any ideas? (7 Replies)
Discussion started by: calsum
7 Replies

7. Filesystems, Disks and Memory

Poor read performance on sun storedge a1000

Hello, i have a a1000 connected to an e6500. There's a raid 10 (12 disks) on the a1000. If i do a dd if=/dev/zero of=/mnt/1 bs=1024k count=1000 and then look at iostat it tells me there's a kw/s of 25000. But if i do a dd of=/dev/zero if=/mnt/1 bs=1024k count=1000 then i see only a... (1 Reply)
Discussion started by: mbrenner
1 Replies

8. Solaris

Move disks to different StorEdge, keeping RAID

Hi. I need to move a 5 disk RAID5 array from a SE3310 box to a different SE3310 array. After installing the disks in the "new" StorEdge device, I "would like" ;) to be able have access to the data which is on the RAID. Essentially, the quesion is, how can this be done? :confused: I checked... (5 Replies)
Discussion started by: alexs77
5 Replies

9. Solaris

Hardware RAID not recognize the new disk [Sun T6320]

We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue. We have 2 LDOM configured on this server and this server running on single disk. #... (8 Replies)
Discussion started by: rock123
8 Replies
stmsboot(1M)															      stmsboot(1M)

NAME
stmsboot - administration program for the Solaris I/O multipathing feature SYNOPSIS
/usr/sbin/stmsboot [-d | -e | -u | -L | -l controller_number] The Solaris I/O multipathing feature is a multipathing solution for storage devices that is part of the Solaris operating environment. This feature was formerly known as Sun StorEdge Traffic Manager (STMS) or MPxIO. The stmsboot program is an administrative command to manage enumeration of fibre channel devices under Solaris I/O multipathing. Solaris I/O multipathing-enabled devices are enumerated under scsi_vhci(7D), providing multipathing capabilities. Solaris I/O multipathing-disabled devices are enumerated under the physical controller. In the /dev and /devices trees, Solaris I/O multipathing-enabled devices receive new names that indicate that they are under Solaris I/O multipathing control. This means a device will have a different name from its original name (following installation) when it is under Solaris I/O multipathing control. The stmsboot command automatically updates /etc/vfstab and dump configuration to reflect the device names changes when enabling or disabling Solaris I/O multipathing. A reboot is required for changes to take effect. The following options are supported: -e Enables Solaris I/O multipathing on all fibre channel (fp(7D)) controller ports. Following this enabling, you are prompted to reboot. During the reboot, vfstab and the dump configuration will be updated to reflect the device name changes. -d Disables Solaris I/O multipathing on all fibre channel (fp(7D)) controller ports. Following this disabling, you are prompted to reboot. During the reboot, vfstab and the dump configuration will be updated to reflect the device name changes. -u Updates vfstab and the dump configuration after you have manually modified the configuration to have Solaris I/O multipathing enabled or disabled on specific fp(7D) controller ports. This option prompts you to reboot. During the reboot, vfstab and the dump configura- tion will be updated to reflect the device name changes. -L Display the device name changes from non-Solaris I/O multipathing device names to Solaris I/O multipathing device names. -l controller_number Display the device name changes from non-Solaris I/O multipathing device names to Solaris I/O multipathing device names for the speci- fied controller. Along with its primary function of enabling or disabling Solaris I/O multipathing, the stmsboot command is used to update vfstab and the dump configuration to reflect device name changes. For a system to function properly, you must configure the applications that consume the devices by old names to use the new names. The -L and -l options display the mapping between the old and new device names. These options work after the changes made to the Solaris I/O multipathing configuration have taken effect. For example, you can use these options following the reboot after invoking stmsboot -e. The old device names must exist in order to display the mappings. Example 1: Enabling Solaris I/O Multipathing Following OS Upgrade To enable Solaris I/O multipathing on all fibre channel (fp(7D)) controller ports run: # stmsboot -e Example 2: Disabling Solaris I/O Multipathing To disable Solaris I/O multipathing on all fibre channel (fp(7D)) controller ports, run: # stmsboot -d Example 3: Enabling Solaris I/O Multipathing on Selected Ports You want to enable Solaris I/O multipathing on some fibre channel controller ports and disable the feature on the rest. You edit the fp.conf file (see fp(7D)) to enable or disable Solaris I/O multipathing on specific controller ports. You then run the following command to have vfstab and the dump configuration updated to reflect the new device names: # stmsboot -u See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |SPARC | +-----------------------------+-----------------------------+ |Availability |SUNWcsu, SUNWcslr | +-----------------------------+-----------------------------+ |Interface Stability |Obsolete | +-----------------------------+-----------------------------+ SEE ALSO
dumpadm(1M), ufsdump(1M), dumpdates(4), vfstab(4), fcp(7D), fctl(7D), fp(7D), qlc(7D), scsi_vhci(7D) Consult the Sun StorEdge Disk Tray [or Subsystem] Administrator's Guide for the T3, 3910, 3960, 6120, and 6320 storage subsystems. Sun StorEdge Traffic Manager Installation and Configuration Guide Solaris I/O multipathing is not supported on all devices. After enabling Solaris I/O multipathing, only those devices that Solaris I/O mul- tipathing supports are placed under Solaris I/O multipathing control. Non-supported devices remain as before. For Solaris releases prior to the current release, the -e and -d options remove the mpxio-disable property entries from fp.conf file (see fp(7D)) and add a global mpxio-disable entry to fp.conf. The current release of the Solaris operating system does not support the mpxio-disable property. Solaris I/O multipathing is always enabled. If you want to disable multipathing, you must use the mechanisms provided by the HBA drivers. See fp(7D). Enabling Solaris I/O Multipathing on a Sun StorEdge Disk Array The following applies to Sun StoreEdge T3, 3910, 3960, 6120, and 6320 storage subsystems. To place your Sun StorEdge disk subsystem under Solaris I/O multipathing control, in addition to enabling Solaris I/O multipathing, the mp_support of the subsystem must be set to mpxio mode. The preferred sequence is to change the subsystem's mp_support to mpxio mode, then run stmsboot -e. If Solaris I/O multipathing is already enabled but the subsystem's mp_support is not in mpxio mode, then change the mp_support to mpxio mode and run stmsboot -u. Refer to the Sun StorEdge Administrator's Guide for your subsystem for more details. ufsdump Users The ufsdump command keeps records of the filesystem dumps in /etc/dumpdates (see dumpdates(4)). Among other items, the records contain device names. An effect of the "active" stmsboot options (-e, -d, and -u) is to change the device name of a storage device. The stmsboot command does not modify the dumpdates file. Because of this, the dumpdates records will refer to the old device names, that is, the device names that were in effect before you ran stmsboot. The effect of this device name-dumpdates disagreement is that, following use of stms- boot, ufsdump will be processed as if no previous dump had ever been made, thus dumping the entire filesystem (effectively, a level 0 dump). Procedure to Use stmsboot in Sun Cluster Environment If possible, use stmsboot -e before you start installing Sun Cluster software. After you run stmsboot, you install Sun Cluster software as you normally would. If you install Sun Cluster software before running stmsboot, you must use the following procedure. On each machine in the cluster on which you want to enable the Solaris multipathing feature, enter: # stmsboot -e ...and allow the system to reboot. When the system comes up, enter the following two commands: 1. # /usr/cluster/bin/scdidadm -C 2. # /usr/cluster/bin/scdidadm -r The preceding commands update did mappings with new device names while preserving did instance numbers for disks that are connected to multiple cluster nodes. did instance numbers of the local disks might not be preserved. For this reason, the did disk names for local disks might change. 3. Update /etc/vfstab to reflect any new did disk names for your local disks. 4. Reboot the system. To disable the Solaris multipathing feature, use stmsboot -d (instead of stmsboot -e), then follow the procedure above. To view mappings between the old and new device names, run stmsboot -L. To view did device name mappings, run /usr/cluster/bin/scdidadm -L. 3 Mar 2005 stmsboot(1M)
All times are GMT -4. The time now is 01:46 PM.