Well I don't know much about "HDS 9500" storage,but in general you need to zone the host HBA Port ( V880 ) with the port on the Storage so that you host could see the storage.Zoning is done on the switch level and command depends upon the type of switch in use.
You can get the WWN number of the host HBA Port ( V880 ) as :
And the WWN number of the storage port can be found out as (for brocad switch only):
Hi:
I am in the process of configuring the SAN for Solaris to host 6 oracle 9i databases. We have 30 -146 GB disks stiped with RAID 10 for SAN. Of which 11 are dedicated for databsaes related things. Then we have 2 v880 Sun Servers with 16 -73 GB disks and 24 GB memory.
The questions... (1 Reply)
I received 4 pre-loaded ready-to-go intel servers running RedHat Enterprise Linux 3 kernel version 2.6.9-22.18 build date june 29, 2006. They are equiped with QLOGIC 2400 dual-port HBA cards. I need to know what utilities or command-sets are available to check these cards out? How do I get their... (4 Replies)
I want to be able to use an account on a solaris 10 server, eg root@myhost
to act as a relay to forward mail to my domain account me@mycompany.com
The reason for this is to configure root@myhost as a mail relay on Brocade SAN switches - so that when a port goes bad i get an email alert.... (0 Replies)
Hi,
I have configured our SAN Storage to be connected to our new SUN T5220.
On the SAn it looks all fine
on the server I do not see any connection:
cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c1 scsi-bus connected ... (4 Replies)
We have a Sun M5000 connecting to a Brocade SAN switch. I don't know the IP of the Brocade switch and don't want to use its serial port to get the info. How can I find the IP of the Brocade switch under Solaris 10? Snoop is not supported by Solaris multipathing. What other tools can I use to find... (6 Replies)
I've seen several posts that are similar to what I'm trying to do but no dice. I have a server (SunFire V215) that went belly up. I've set up a new one. I'm getting a corrupt label: wrong magic number error. Everything I'm seeing says label the drives, but if I do I'm afraid I'll lose the data... (0 Replies)
Hi,
We have a OEL6.1 installed on our server.
We want developers to view there application logs generated on the server, but doesn't really want to give them access to server machine.
Can someone please suggest how can we configure apache/httpd to create a url which will show all files in... (1 Reply)
Hi my name is Manju.
->I have configure the two way authentication on my linux server.
->Now I am able to apply two way authenticator on particuler user.
->Now I want to map this linux server to my AD server.
->Kindly tell me how to map AD(Active Directory) with this linux server.
... (2 Replies)
Hi my name is Manju.
->I have configure the two way authentication on my linux server.
->Now I am able to apply two way authenticator on particuler user.
->Now I want to map this linux server to my AD server.
->Kindly tell me how to map AD(Active Directory) with this linux server.
... (0 Replies)
Hi Team,
How do i mount or connect the SAN storage to a specific folder. I have tried to mount it but each time i can only mount 900GB of the storage to the folder:
ipmi1 ~]# df -h
Filesystem Size Used Avail Use% Mounted on
/dev/mapper/VolGroup-root_vol
... (0 Replies)
Discussion started by: ElVista
0 Replies
LEARN ABOUT HPUX
st_san_safe
st_san_safe(5) OBSOLETED st_san_safe(5)NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED)
VALUES
Failsafe
Default
Allowed values
Recommended values
or
DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3.
This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When
this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with
a status of
The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files
without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from
HP-UX systems via standard tape commands like which would corrupt a backup in process.
Who Is Expected to Change This Tunable?
Anyone.
Restrictions on Changing
Changes to this tunable take effect immediately.
When Should the Tunable Be Turned On?
This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration.
What Are the Side Effects of Turning the Tunable On?
The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This
behavior prevents the usage of any tape device special file without the no-rewind-on-close option.
When Should the Tunable Be Turned Off?
This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not
function unless it has access to device special files without the no-rewind-on-close option.
What Are the Side Effects of Turning the Tunable Off?
A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard.
SEE ALSO norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7).
Tunable Kernel Parameters st_san_safe(5)