Sponsored Content
Operating Systems Solaris Sun T5120 hardware RAID question Post 302402542 by soliberus on Wednesday 10th of March 2010 05:16:22 AM
Old 03-10-2010
Sun T5120 hardware RAID question

Hi everyone

I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive.

My question is, how would I know when one of the drives become faulty?

Thanks
 

9 More Discussions You Might Find Interesting

1. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

2. Solaris

How to destroy hardware raid on T5120

Hi, I have problem creating hardware raid on T5120 with 4 disks. After the hardware raid 1 created, then I used the raidctl -l c1t0d0 and raidctl -l c1t2d0 the output of volume c1t0d0 contain disk 0.0.0 0.1.0, also the volume c1t2d0 contain disk 0.0.0 0.1.0 and should be 0.2.0 0.3.0 so I... (15 Replies)
Discussion started by: netlink
15 Replies

3. Solaris

Small issue with Sun Sparc Enterprise T5120

Good Day, We have bought Sun Sparc Enterprise T5120 with pre-installed Solaris 10 Sparc But i need on this server Solaris 9. I have inserted in to DVD-rom (USB DVD-rom) with Solaris 9 for Sparc. Then log into shell and type: reboot -- cdrom. System rebooted and i have this message: ... (3 Replies)
Discussion started by: A.Shalin
3 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Sun V240 Raid Question

Hi All, I'm new to this site. I have a few question since I'm in the process how to to repair my raid on Sun V240 Server. 1. How can we create RAID in Sun Sparc v240? 2. What utility can help people create RAID in Sun Sparc v240? 3. Do we need any special software to create the... (12 Replies)
Discussion started by: angkor
12 Replies

9. Solaris

Hardware RAID not recognize the new disk [Sun T6320]

We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue. We have 2 LDOM configured on this server and this server running on single disk. #... (8 Replies)
Discussion started by: rock123
8 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g,. hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing pre-configured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, etc. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 3.53 of the Linux man-pages project. A description of the project, and information about reporting bugs, can be found at http://www.kernel.org/doc/man-pages/. Linux 2012-08-05 HPSA(4)
All times are GMT -4. The time now is 03:25 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy