Sponsored Content
Operating Systems Solaris Please help...my HBA's won't configure Post 302401882 by trickydicky on Monday 8th of March 2010 06:44:30 AM
Old 03-08-2010
showrev:

Hostname: ipcc-ndbs-001
Hostid: 841e75f7
Release: 5.10
Kernel architecture: sun4u
Application architecture: sparc
Hardware provider: Sun_Microsystems
Domain:
Kernel version: SunOS 5.20 Generic_118822-10

cfgadm -al:

App_Id Type Receptacle Occupant Condition
PCI0 unknown empty unconfigured unknown
PCI1 unknown empty unconfigured unknown
PCI2 unknown empty unconfigured unknown
PCI3 unknown empty unconfigured unknown
PCI4 pci-pci/hp connected configured ok
PCI5 pci-pci/hp connected configured ok
PCI6 pci-pci/hp connected configured ok
PCI7 mult/hp connected configured ok
PCI8 mult/hp connected configured ok
c0 scsi-bus connected configured ok
c0::dsk/c0t0d0 CD-ROM connected configured ok
c1 fc-private connected configured unknown
c1::21000014c3cf742f disk connected configured unknown
c1::21000014c3cf7493 disk connected configured unknown
c1::21000014c3cf76fb disk connected configured unknown
c1::21000014c3cf7af8 disk connected configured unknown
c1::50800200002273c1 disk connected configured unknown
c2 fc-fabric connected unconfigured unknown
c2::210000e08b89a094 unknown connected unconfigured unknown
c2::500a098887099920 unknown connected unconfigured unknown
c2::500a098897099920 unknown connected unconfigured unknown
c3 fc-fabric connected configured unknown
c3::50060e8004f28a2a disk connected configured unknown
c4 fc-fabric connected unconfigured unknown
c4::500a098587099920 unknown connected unconfigured unknown
c4::500a098597099920 unknown connected unconfigured unknown
c5 fc-fabric connected configured unknown
c5::50060e8004f27c3a disk connected configured unknown
c5::50060e8004528a4a disk connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb0/3 unknown empty unconfigured ok
usb0/4 unknown empty unconfigured ok

cat /etc/release:

Solaris 19 3/05 HW1 s10s_wos_74L2a SPARC
Copyright 2005 Sun Microsystems, Inc. All Rights Reserved
Use is subject to license terms.
Assembled 14 July 2005


Thanks
Rich
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Hardware HBA problem

I have worked with Qlogic (Sun) fiber cards a lot and with Emulex fiber cards only a little. Here is the scenario: I have a Sun 490 with 3 Emulex cards in it. A pair are for the 6120 array that is attached, the other is a direct attach so our SAN for Veritas Netbackup to back up the system.I... (0 Replies)
Discussion started by: lm_admin_dh
0 Replies

2. AIX

How to configure a FC HBA in "initiator mode"?

Hi all, I have a p520 machine running 5.2ML9 with a 2Gb FC HBA from IBM, i.e. # lscfg -vl fcs0 fcs0 U787A.001.DNZ06YM-P1-C3-T1 FC Adapter Part Number.................80P4543 EC Level....................A Serial Number...............1F4270A0B6 ... (5 Replies)
Discussion started by: Bookie
5 Replies

3. Solaris

HBA Card

Hello...I got a problem here. I have HBAs installed in one of the domains in E20 and I gotta find out the brand and firmware. But when I do a prtconf, I cannot see the HBA. For other servers installed with HBAs, when I do prtconf on them I can see either qlc or em. Can you guys enlighten me how to... (5 Replies)
Discussion started by: xiaochensg
5 Replies

4. Solaris

What is an HBA..?

Helo experts What is an HBA? How can i know about that on any server? Thanx in advance... (7 Replies)
Discussion started by: younus_syed
7 Replies

5. AIX

won't mount /usr...won't boot fully

Hello: NOOB here. I attempted to use smit mkcd. Failed on first attempt, not enough space. 2nd attempt tried to place iso on /usr, not enough space there. Cleanup ran for about 5 minutes after aborting. Now AIX won't boot. LCD display on 7029-6E3 says: 0517 MOUNT /USR. Attempted to boot from CD... (11 Replies)
Discussion started by: bbird
11 Replies

6. Filesystems, Disks and Memory

HBA performance

Hope I'm in the right place. I'm in the process of zoning HBA's to my new library environment. Is there a "rule of thumb" for the number of physical tape drives that you zone to an HBA? I don't want to run the risk of overloading an HBA. Any information would be greatly appreciated. Thanks. (2 Replies)
Discussion started by: jwholey
2 Replies

7. Solaris

Offline HBA.

Hi, I have a HBA that is currently offline for some unknown reason. The device shows up in the prtdiag -v stating it is okay. How can I bring this back online? It was working okay until recently. It is currently connected to the SAN. Details below. # fcinfo hba-port HBA Port WWN:... (7 Replies)
Discussion started by: sparcman
7 Replies

8. Solaris

HBA disappeared after reboot

Hello all I was configuring a SUN 2540 raid and after a reboot the hba`s is gone. There is no longer an entry in etc/path_to_inst for them (2 cards). I tried a reconfigure boot several times but it does not work. The hba`s is a SUN qlogic 2200 in x4240 server (AMD). Using solaris 10 update7.... (6 Replies)
Discussion started by: vettec3
6 Replies

9. Solaris

How to enable hba port of a two port hba card

Hi, i have a two port hba card in solaris 10 system one of which is disabled. How to enable and configure the other port. ---------- Post updated at 08:17 AM ---------- Previous update was at 03:40 AM ---------- please help :( (7 Replies)
Discussion started by: rishiraaz
7 Replies

10. UNIX for Beginners Questions & Answers

Bash script won't run because hardware won't produce display

Can anyone offer any advice on how to modify the script below to work on a new system we have, that has no graphics capability? We admin the system through a serial RAS device. I've tried running the below script through the RAS and through an ssh -X session. It failed with something like "GTK... (3 Replies)
Discussion started by: yelirt5
3 Replies
cfgadm_pci(1M)						  System Administration Commands					    cfgadm_pci(1M)

NAME
cfgadm_pci - PCI Hotplug hardware specific commands for cfgadm SYNOPSIS
/usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -c function ap_id [ap_id] /usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -x hardware_function ap_id [ap_id] /usr/sbin/cfgadm [-v] [-s listing_options] [-o hardware_options] [-l [ ap_id | ap_type]] /usr/sbin/cfgadm [-v] [-o harware_options] -t ap_id [ap_id] /usr/sbin/cfgadm [-v] [-o hardware_function] -h [ ap_id| ap_type] DESCRIPTION
The PCI hardware specific library /usr/lib/cfgadm/pci.so.1 provides the support for hot plugging pci adapter cards into pci hot pluggable slots in a system that is hot plug capable, through the cfgadm command. See cfgadm(1M). For PCI Hot Plug, each hot plug slot on a specific PCI bus is represented by an attachment point of that specific PCI bus. An attachment point consist of two parts: a receptacle and an occupant. The receptacle under PCI hot plug is usually referred to as the physical hot pluggable slot; and the occupant is usually referred to as the PCI adapter card that plugs into the slot. Attachment points are named through ap_ids. There are two types of ap_ids: logical and physical. The physical ap_id is based on the physi- cal pathname, that is, /devices/pci@1/hpc0_slot3, whereas the logical ap_id is a shorter, and more user-friendly name. For PCI hot plug- gable slots, the logical ap_id is usually the corresponding hot plug controller driver name plus the logical slot number, that is, pci0:hpc0slot1; pci nexus driver, with hot plug controller driver named hpc and slot number 1. The ap_type for Hot plug PCI is pci. Note that the ap_type is not the same as the information in the Type field. See the System Administration Guide: Basic Administration for a detailed description of the hot plug procedure. OPTIONS
The following options are supported: -c function The following functions are supported for PCI hot pluggable slots: configure Configure the PCI device in the slot to be used by Solaris. connect Connect the slot to PCI bus. disconnect Disconnect the slot from the PCI bus. insert Not supported. remove Not supported. unconfigure Logically remove the PCI device's resources from the system. -f Not supported. -h ap_id | ap_type Print out PCI hot plug specific help message. -l list List the values of PCI Hot Plug slots. -o hardware_options No hardware specific options are currently defined. -s listing_options Same as the generic cfgadm(1M). -t ap_id This command is only supported on platforms which support testing capability on the slot. -v Execute in verbose mode. When -v is used with -l option the cfgadm command outputs information about the attachment point. For PCI Hot Plug, the Information field will be the slot's system label. This string will be obtained from the slot-name property of the slot's bus node. The information in the Type field is printed with or without the -v option. The occupant Type field will describe the contents of the slot. There are 2 possible values: unknown The slot is empty. If a card is in the slot, the card is not configured or there is no driver for the device on the card. subclass/board The card in the slot is either a single-function or multi-function device. subclass is a string representing the subclass code of the device, for example, SCSI, ethernet, pci-isa, and so forth. If the card is a multi-functional device, MULT will get printed instead. board is a string representing the board type of the device. For example, hp is the string used for a PCI Hot Plug adapter, hs is used for a Hot Swap Board, nhs for a Non--Hot Swap cPCI Board, bhs for a Basic Hot Swap cPCI Board, and fhs for a Full Hot Swap cPCI Board. Most pci cards with more than one device are not multi-function devices, but are implemented as a pci bridges with arbitrary devices behind them. In those cases, the subclass displayed is that of the pci bridge. Most com- monly the bridges are pci-pci, a generic pci to pci bridge or stpci, a semi-transparent pci bridge. -x hardware_function Perform hardware specific function. These hardware specific functions should not normally change the state of a receptacle or occupant. The following hardware_functions are supported: enable_slot | disable_slot Change the state of the slot and preserve the state of slot across reboot. Preservation of state across reboot is only supported on select platforms. enable_slot enables the addition of hardware to this slot for hot plugging and at boot time. disable_slot disables the addition of hardware to this slot for hot plugging and at boot time. When a slot is disabled its condi- tion is shown as unusable. enable_autoconfig | disable_autoconfig Change the ability to autoconfigure the occupant of the slot. Only platforms that support auto configuration support this feature. enable_autoconfig enables the ability to autoconfigure the slot. diable_autoconfig disables the ability to autoconfigure the slot. led=[led_sub_arg],mode=[mode_sub_arg] Without sub-arguments, print a list of the current LED settings. With sub-arguments, set the mode of a specific LED for a slot. Specify led_sub_arg as fault, power, att, or active. Specify mode_sub_arg as on, off or blink. Changing the state of the LED does not change the state of the receptacle or occupant. Normally, the LEDs are controlled by the hot plug controller, no user intervention is necessary. Use this command for testing purposes. Caution: Changing the state of the LED can misrepresent the state of occupant or receptacle. The following command prints the values of LEDs: example# cfgadm -x led pci0:hpc0_slot1 Ap_Id Led pci0:hpc0_slot1 power=on,fault=off,active=off,attn=off The following command turns on the Fault LED: example# cfgadm -x led=fault,mode=on pci0:hpc0_slot1 The following command turns off the Power LED: example# cfgadm -x led=power,mode=off pci0:hpc0_slot0 The following command sets the active LED to blink to indicate the location of the slot: example# cfgadm -x led=active,mode=on pci0:hpc0_slot3 EXAMPLES
Example 1: Printing out the Value of Each Slot The following command prints out the values of each slot: example# cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok Example 2: Replacing a Card The following command lists all DR-capable attachment points: example# cfgadm Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok The following command unconfigures and electrically disconnects the card: example# cfgadm -c disconnect cpci_slot4 The change can be verified by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 unknown disconnected unconfigured unknown Now the card can be swapped. The following command electrically connects and configures the card: example# cfgadm -c configure cpci_slot4 The change can be verifed by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 stpcipci/fhs connected configured ok FILES
/usr/lib/cfgadm/pci.so.1 Hardware specific library for PCI hot plugging. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWkvm.u | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5) System Administration Guide: Basic Administration SunOS 5.10 27 Oct 2003 cfgadm_pci(1M)
All times are GMT -4. The time now is 08:19 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy