Sponsored Content
Operating Systems Linux Help in monitoring performance problem in Linux Post 302395040 by TonyFullerMalv on Sunday 14th of February 2010 12:16:44 PM
Old 02-14-2010
If it is 2 disk RAID 5 then it is an utter waste of time and explains the poor I/O performance, take the two disks and mirror one against the other instead.
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

performance monitoring

hi, can any one tell me, is there is any way i can check the performance of my solaris 8 os on an Ent 3500. Other than top to check for the top most processes, how to make the calculations with vmstat, iostat, mpstat and nfsstat. Or is there any other tools that i can use? cheers. (3 Replies)
Discussion started by: i2admin
3 Replies

2. AIX

Performance monitoring

Hi All I am looking for a script that would collect statistics in a summarised format. CPU, Memory,Swap, Wait queue, Run queue and disk activity. Something that would allow me to profile the environment based on a 1 line output that I could run every 15 min. Thx Junaid (1 Reply)
Discussion started by: jhansrod
1 Replies

3. UNIX for Advanced & Expert Users

Performance Monitoring

Hi all The place I work for is about to to place there database server under heavy load for testing and would like the effect recorded as much as possible. Can anyone point me in the right direction with respect to real time system monitoring. I am aware of of 'sar', vmstat etc and hope to... (2 Replies)
Discussion started by: silvaman
2 Replies

4. UNIX for Dummies Questions & Answers

Performance monitoring

Hello, I am trying to find a way to view current CPU and disk usage. I used to use nmon which worked fine but since an upgrade to our servers this is no longer available. I have tried to get it reinstalled to no avail! Are there any other commands you can use within unix which will allow me... (4 Replies)
Discussion started by: johnwilliams
4 Replies

5. Linux

Linux/Unix performance monitoring

This is my first post (yes I'm a newbie).... :D I'm looking for a list of Linux and Unix commands for performance monitoring and a good sight or area on this site that would have man pages and or information on those commands..... Thanks if anyone can take the time to post..... :cool: (14 Replies)
Discussion started by: harrisjl
14 Replies

6. Solaris

Performance Monitoring

Hi all, I am planning to give a presentation on performance measure. I have decided to focus on the commands which are used to know the performance of the server. I have a idea of prstat,vmstat,netstat, and iostat. Could anybody suggest me any other commands which are used for perforamance... (7 Replies)
Discussion started by: priky
7 Replies

7. Shell Programming and Scripting

Performance monitoring help needed.

How would i check for following? 1)open ports in my linux machine. 2)Hard disk read speed. 3)Hard disk write speed. (2 Replies)
Discussion started by: pinga123
2 Replies

8. AIX

Performance Monitoring of FileSystem

As I am new to the Unix field, I would like to get the clarification regarding the Filesystem. The scenario is.. The filesystem (/drbackup) is getting monitored and if it exceeds the threshold, we will receive an alert from it. The issue is that we receive an alert with the description of... (2 Replies)
Discussion started by: A.Srenivasan
2 Replies

9. Solaris

Performance / Batch monitoring

What tools can I use to look "deeper" into a process to see if the job is actually running or just hanging. What is the best method to accomplish this? SunOS 5.10 Generic_142900-14 sun4v sparc SUNW,T5240 (2 Replies)
Discussion started by: Harleyrci
2 Replies

10. Red Hat

HELP - Resource/Performance Monitoring Script - Red Hat Enterprise Linux Server

Hi all, ------------------------- Linux OS Version/Release: ------------------------- Red Hat Enterprise Linux Server release 5.5 (Tikanga) Linux <hostname> 2.6.18-194.8.1.el5 #1 SMP Wed Jun 23 10:52:51 EDT 2010 x86_64 x86_64 x86_64 GNU/Linux I have a server that hosts 30+ Oracle... (1 Reply)
Discussion started by: newbie_01
1 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), mount(8), newfs(8), vinum(8) HISTORY