Hope this would help.
If you have multiple hard drives, there is one more caveat. If your drives are IDE (PATA) hard drives, the /boot directory must be on a hard drive attached to the primary IDE controller. If your drives are all SCSI hard drives, the /boot directory must be located on a hard drive with SCSI ID 0 or ID 1. If you have a mix of hard drives, the /boot directory must be located on either the first IDE drive or a SCSI drive with ID 0.
This User Gave Thanks to sunsj For This Post:
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hey !
I am running EWS-UX/V (Rel 4.2) on NEC EWS/4800/330 station and I am having problems rebooting my station : I am getting the following message on display : BOOT : PANIC : File size out of range.
According to user guide, this error is occuring when a file exceeding the limit and/or... (2 Replies)
Discussion started by: fredo
2 Replies
2. Solaris
When I installed the SOLARIS 10 OS first time, the desktop would not start up, this was because of network setup. Reinstalled worked. After a week due to some problem I had to reinstall OS, installation went fine and but when i reboot I get this error.
cannot find mis/krtld
boot error loading... (0 Replies)
Discussion started by: johncy_j
0 Replies
3. Solaris
I'm running solaris 2.5.1. My main development server is DEAD, i can't even boot off the cdrom, it powers up, acts like it is starting the boot process but then says cannot find boot device. I've done the search here on this site and saw the other posts, but at the ok prompt it won't even let me... (3 Replies)
Discussion started by: kymberm
3 Replies
4. Solaris
Help needed please! I see the following scsi errors during boot up. The server eventually boots up successfully. Please let me now how to fix these errors:
Executing last command: boot
Boot device: disk File and args:
SunOS Release 5.8 Version Generic_117350-62 64-bit
Copyright 1983-2003 Sun... (4 Replies)
Discussion started by: pingmeback
4 Replies
5. SCO
hi
SCO Unix 5.0.6 doesn't boot due to this problem:
not a directory
boot not found
cannot open
stage 1 boot failure: error loading hd (40)/boot
Knows someone howto solve it? (16 Replies)
Discussion started by: ccc
16 Replies
6. Boot Loaders
Hello,
I have kubuntu on my laptop and now I decided to switch to Windows 7. I made the bios settings properly (first choice is boot from cd\vd) but I see the error
" reboot and select proper Boot device or insert Boot media in select Boot device and press a key "
I have tried CD and... (0 Replies)
Discussion started by: rpf
0 Replies
7. Solaris
I am trying to install Solaris x86 using the Jumpstart server. I run the add_install_client command with appropriate options, and reboot my x86 Target box. The installation starts fine and unattended. After the installation completes and the target goes for a re-boot, it does not boot from the HDD... (9 Replies)
Discussion started by: hemalsid
9 Replies
8. Hardware
I have a server with a scsi raid controller (for hard drives) and a scsi controller (for tape drive and cd-rom). I am trying to boot from the cd-rom but can't. During boot up, bootable media is detected in the cd-rom but the system will not boot from it. BIOS for the raid controller installs but... (1 Reply)
Discussion started by: powwm
1 Replies
9. Solaris
Hi Solaris 10 Experts,
I am wondering what is the correct syntax to edit in Grub when trying to specify the local ZFS boot disk while booting up from a Solaris 10 x86 64bits DVD installation disk. In other word, I try to boot up from local disk without removing the Solaris installation disk... (0 Replies)
Discussion started by: gjackson123
0 Replies
IDA(4) BSD Kernel Interfaces Manual IDA(4)
NAME
ida -- Compaq Intelligent Drive Array Controllers
SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file:
device scbus
device ida
Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5):
ida_load="YES"
DESCRIPTION
The Compaq Intelligent Drive Array (IDA) technology is used to distribute data across an array of hard drives. It unites these hard drives
into one or more high-performance logical drives. The drive array is managed by an array controller.
These controllers have the ability to provide fault tolerance for the connected drives and optionally provide write cache for the logical
drives. It is also possible for an application to access the SCSI bus subsystem directly by using the pass-through interface.
HARDWARE
The following controllers are supported by the ida driver:
o Compaq SMART Array 221
o Compaq Integrated SMART Array Controller
o Compaq SMART Array 4200
o Compaq SMART Array 4250ES
o Compaq SMART 3200 Controller
o Compaq SMART 3100ES Controller
o Compaq SMART-2/DH Controller
o Compaq SMART-2/SL Controller
o Compaq SMART-2/P Controller
o Compaq SMART-2/E Controller
o Compaq SMART Controller
IMPLEMENTATION NOTES
Extreme caution should be exercised when using the pass-through interface. It is possible to interfere with normal system I/O and cause
hangs if pass-through is used to an active device. Pass-through should only be used to a device that is otherwise quiescent.
SEE ALSO
cam(4), pass(4), xpt(4), camcontrol(8)
AUTHORS
The ida driver was written by Jonathan Lemon <jlemon@FreeBSD.org> and Matthew N. Dodd <mdodd@FreeBSD.org>. This manual page was written by
Tom Rhodes <trhodes@FreeBSD.org>.
BSD
August 8, 2004 BSD