12-19-2009
Is you route to the switch ok? are you able to ping? if not, fix that first
10 More Discussions You Might Find Interesting
1. HP-UX
Hi,
Please advise me whereas I have two node cluster server configured with MC/SG. Application and DB are running on Node 1, while Node 2 is standby.
All the volume group devices are part of cluster environment. There is only one package running at node 1.
Node 2 is having the problem to... (1 Reply)
Discussion started by: rauphelhunter
1 Replies
2. AIX
This post just as a follow-up for thread https://www.unix.com/aix/115548-hacmp-5-4-aix-5300-10-not-working.html: there was a bug in the clcomdES that would cause the Two-Node-Cluster-Configuration-Assistant to fail even with a correct TCP/IP adapter setup. That affected HACMP 5.4.1 in combinatin... (0 Replies)
Discussion started by: shockneck
0 Replies
3. Solaris
Hello
I have problem with scinstall. I found information that i should`t configure public network before using scinstall.
Each node configuration:
4 node, 3 network adapter on each node. 1 for public adapter and 2 for cluster interconnect. Two switches.
After scinstall first node is... (1 Reply)
Discussion started by: time0ut
1 Replies
4. Solaris
Need some one to explain "In cluster configuration ora* VGs are not controlled by VCS". Actually, I am not aware of this.
Thanks,
Rama (0 Replies)
Discussion started by: ramareddi16
0 Replies
5. Solaris
I am using VMware Workstation-7 on Windows-XP host .
I am trying to configure Solaris 10-X86 guest os based 2 nodes Sun Cluster .
I have added one extra Virtual Lan adapter on my VMware with another subnet (that I would like to put for SUN Cluster private communication).
I have... (0 Replies)
Discussion started by: sanjee
0 Replies
6. UNIX for Advanced & Expert Users
Hi - Please help me to understand the Veritas Cluster fail-over capability.
We configured oracle database file system on veritas cluster file system and it is automatically failing-over from node 1 to node 2.
Does Veritas cluster softward have any option to fail-back from node 2 to node 1... (6 Replies)
Discussion started by: Mansoor8810
6 Replies
7. Red Hat
Hi Everybody,
I would like to know meaning of following parameters in cluster.conf file in linux
<device name="blade_fence" blade="2" option="off"
<clusternode name="Blade1-int" votes="1" nodeid="1">
what do you mean by "option=off" and "votes=1"
Thanks (1 Reply)
Discussion started by: mastansaheb
1 Replies
8. UNIX and Linux Applications
Hi Experts,
I have question regarding linux cluster managment on Red Hat 5.x server. When I try to install 'luci' or 'ricci' in one of our linux servers it is giving me below error:-
yum install luci
Loaded plugins: katello, product-id, rhnplugin, security, subscription-manager
Updating... (0 Replies)
Discussion started by: Amey Joshi
0 Replies
9. Emergency UNIX and Linux Support
Hello HP-UX experts,
Server = rx8640 Node partition
OS = HP-UX 11.23
arch = IA64
Network switch = Foundry 16 port switch (1Gbps)
Existing configuration: Tough to explain as it is very messy (see below for the link of zip of network related fles). 2 x 2Gbps aggregates configured some time... (1 Reply)
Discussion started by: prvnrk
1 Replies
10. Red Hat
why does my cluster form but fail after a few minutes, or why do my multicast communications stop working after a short amount of time? (1 Reply)
Discussion started by: gema.utama
1 Replies
LEARN ABOUT CENTOS
ocf_pacemaker_ping
OCF_PACEMAKER_PING(7) Pacemaker Configuration OCF_PACEMAKER_PING(7)
NAME
ocf_pacemaker_ping - node connectivity
SYNOPSIS
[OCF_RESKEY_pidfile=string] [OCF_RESKEY_dampen=integer] [OCF_RESKEY_name=string] [OCF_RESKEY_multiplier=integer]
[OCF_RESKEY_host_list=string] [OCF_RESKEY_attempts=integer] [OCF_RESKEY_timeout=integer] [OCF_RESKEY_options=string]
[OCF_RESKEY_failure_score=integer] [OCF_RESKEY_debug=string] ping [start | stop | reload | monitor | meta-data | validate-all]
DESCRIPTION
Every time the monitor action is run, this resource agent records (in the CIB) the current number of ping nodes the host can connect to. It
is essentially the same as pingd except that it uses the system ping tool to obtain the results.
SUPPORTED PARAMETERS
OCF_RESKEY_pidfile = string [/ping-]
PID file
OCF_RESKEY_dampen = integer [5s]
Dampening interval
The time to wait (dampening) further changes occur
OCF_RESKEY_name = string [pingd]
Attribute name
The name of the attributes to set. This is the name to be used in the constraints.
OCF_RESKEY_multiplier = integer []
Value multiplier
The number by which to multiply the number of connected ping nodes by
OCF_RESKEY_host_list = string []
Host list
The list of ping nodes to count.
OCF_RESKEY_attempts = integer [2]
no. of ping attempts
Number of ping attempts, per host, before declaring it dead
OCF_RESKEY_timeout = integer [2]
ping timeout in seconds
How long, in seconds, to wait before declaring a ping lost
OCF_RESKEY_options = string []
Extra Options
A catch all for any other options that need to be passed to ping.
OCF_RESKEY_failure_score = integer []
failure_score
Resource is failed if the score is less than failure_score. Default never fails.
OCF_RESKEY_debug = string [false]
Verbose logging
Enables to use default attrd_updater verbose logging on every call.
AUTHOR
Andrew Beekhof <andrew@beekhof.net>
Author.
Pacemaker Configuration 06/10/2014 OCF_PACEMAKER_PING(7)