Sponsored Content
Full Discussion: How to replace failed disk?
Operating Systems Solaris How to replace failed disk? Post 302381667 by tamitot on Saturday 19th of December 2009 12:27:54 PM
Old 12-19-2009
describe how your system is setup.

in general, if you have a mirrored boot disk, you have to break the mirror first then shut down the system and replace the faulty hdd.
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Scsi Disk Failed

My WS boot disk has failed so when i want to boot system (by OK boot -s or Ok boot disk0 ) i get these mesgs: disk read error boot :can not find misc/sparc9v/krtld boot:error loading interperetor (misc/sparc9v/krtld) Elf64 read error. boot failed. although it's probed ,finally i try... (1 Reply)
Discussion started by: nikk
1 Replies

2. AIX

Replace a Failed Root Disk in AIX

My root disk is failed and how to replace the root disk in AIX. Can u give a detailed explanation in step wise. Pls give the answer taking different scenarios. Regards Praveen (1 Reply)
Discussion started by: chinnu_mulakala
1 Replies

3. Solaris

How can we confirm that, the disk has failed in Solaris?

Hi All, Seems to be one of the disk has failed on my Solaris server. How do i confirm that disk has really failed or not? Here are alert details. ------- iostat -En out/put c1t3d0 Soft Errors: 1884 Hard Errors: 153 Transport Errors: 54 Vendor: FUJITSU Product:... (3 Replies)
Discussion started by: Naresh Kommina
3 Replies

4. Solaris

Step by step to replace Failed disk

Hi all. This may be a stupid question but here goes: I lost a disk on my Sun-Fire 480-r and want to replace it. I don't care about the data, I just need to get a new disk in. Can anyone supply me with step by step procedure please. I am not an expert by any means and it is a dev box so I... (1 Reply)
Discussion started by: jamie_collins
1 Replies

5. Solaris

Cannot remove and replace failed disk

-bash-3.00# zpool detach zonepool c1t1d0 cannot detach c1t1d0: only applicable to mirror and replacing vdevs -bash-3.00# zpool remove zonepool c1t1d0 cannot remove c1t1d0: only inactive hot spares, cache, top-level, or log devices can be removed -bash-3.00# zpool offline zonepool c1t1d0... (3 Replies)
Discussion started by: LittleLebowski
3 Replies

6. UNIX for Advanced & Expert Users

Identify failed disk in Linux RAID

Good Evening, 2 years ago, I set up an Ubuntu file-server for a friend, who is a photograph amateur. Basically, the server offers a software RAID-5 that can be accessed remotely from a MAC. Unfortunately, I didn't labeled the hard drives (i.e. which physical drive corresponds to the /dev/sdX... (2 Replies)
Discussion started by: Loic Domaigne
2 Replies

7. Red Hat

Find out the failed disk

Hi Masters, How to find out the failed disk in redhat linux (OR) How to decalare whether our hard disk goes bad ? My option is: dmesg | grep "failed" check in /var/log/messages with the kernel error. Please corrrect me if im wrong. And also i heard "smartctl" command. But it's... (2 Replies)
Discussion started by: abhay1983
2 Replies

8. Solaris

Recover failed system disk

I have an oldish Solaris 10 system (SunFire x4240), which due to a recent heating event in the server room, lost it's system disk. I have rsync backups of all the other (data) disks, but apparently I do not have a backup of /. :-( I can start the machine up in failsafe mode, but running fsck on... (4 Replies)
Discussion started by: jj5406
4 Replies

9. AIX

Failed Disk,unable to varyonvg

Iam new to AIX I am unable varyonvg on the vios,some of the disk are reported as harware failure. I am going to replace the disk,Please tell me how to remove the disk without any corruption in the VG lspv -l hdiskx also didn't work (0 Replies)
Discussion started by: roayaix
0 Replies

10. Solaris

Replacing a failed disk using SVM

Hi Please can you help me on replacing or removing a faulty disk drive on a SUN NETRA X4250server with 4 internal drives only. the format comand show me the following: format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <drive type unknown> ... (9 Replies)
Discussion started by: fretagi
9 Replies
vxsparecheck(1M)														  vxsparecheck(1M)

NAME
vxsparecheck - monitor Veritas Volume Manager for failure events and replace failed disks SYNOPSIS
/etc/vx/bin/vxsparecheck [mail-address...] DESCRIPTION
The vxsparecheck command monitors Veritas Volume Manager (VxVM) by analyzing the output of the vxnotify command, waiting for failures to occur. It then sends mail via mailx to the logins specified on the command line, or (by default) to root. It then replaces any failed disks. After an attempt at replacement is complete, mail will be sent indicating the status of each disk replacement. The mail notification that is sent when a failure is detected follows this format: Failures have been detected by the Veritas Volume Manager: failed disks: medianame ... failed plexes: plexname ... failed subdisks: subdiskname ... failed volumes: volumename ... The Volume Manager will attempt to find hot-spare disks to replace any failed disks and attempt to reconstruct any data in volumes that have storage on the failed disk. The medianame list specifies disks that appear to have completely failed. The plexname list show plexes of mirrored volumes that have been detached due to I/O failures experienced while attempting to do I/O to subdisks they contain. The subdiskname list specifies subdisks in RAID-5 volumes that have been detached due to I/O errors. The volumename list shows non-RAID-5 volumes that have become unusable because disks in all of their plexes have failed (and are listed in the ``failed disks'' list) and shows those RAID-5 volumes that have become unusable because of multiple failures. If any volumes appear to have failed, the following paragraph will be included in the mail: The data in the failed volumes listed above is no longer available. It will need to be restored from backup. Replacement Procedure After mail has been sent, vxsparecheck finds a hot spare replacement for any disks that appear to have failed (that is, those listed in the medianame list). This involves finding an appropriate replacement for those eligible hot spares in the same disk group as the failed disk. A disk is eligible as a replacement if it is a valid Veritas Volume Manager disk (VM disk), has been marked as a hot-spare disk and con- tains enough space to hold the data contained in all the subdisks on the failed disk. To determine which disk from among the eligible hot spares to use, vxsparecheck first checks the file /etc/vx/sparelist (see Sparelist File below). If this file does not exist or lists no eligible hot spares for the failed disk, the disk that is ``closest'' to the failed disk is chosen. The value of ``closeness'' depends on the controller, target and disk number of the failed disk. A disk on the same controller as the failed disk is closer than a disk on a different controller; and a disk under the same target as the failed disk is closer than one under a different target. If no hot spare disk can be found, the following mail is sent: No hot spare could be found for disk medianame in diskgroup. No replacement has been made and the disk is still unusable. The mail then explains the disposition of volumes that had storage on the failed disk. The following message lists disks that had storage on the failed disk, but are still usable: The following volumes have storage on medianame: volumename These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If any non-RAID-5 volumes were made unusable due to the failure of the disk, the following message is included: The following volumes: volumename have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. If any RAID-5 volumes were made unavailable due to the disk failure, the following message is included The following RAID-5 volumes: volumename had storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. If a hot-spare disk was found, a hot-spare replacement is attempted. This involves associating the device marked as a hot spare with the media record that was associated with the failed disk. If this is successful, the vxrecover(1M) command is used in the background to recover the contents of any data in volumes that had storage on the disk. If the hot-spare replacement fails, the following message is sent: Replacement of disk medianame in group diskgroup failed. The error is: error message If any volumes (RAID-5 or otherwise) are rendered unusable due to the failure, the following message is included: The following volumes: volumename occupy space on the failed disk and have no other available mirrors or have experienced other failures. These volumes are unusable, and the data they contain is unavailable. If the hot-spare replacement procedure completed successfully and recovery is under way, a final mail message is sent: Replacement of disk medianame in group diskgroup with disk device sparedevice has successfully completed and recovery is under way. If any non-RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following volumes: volumename occupy spare on the replaced disk, but have no other enabled mirrors on other disks from which to perform recovery. These volumes must have their data restored. If any RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following RAID-5 volumes: volumename have subdisks on the replaced disk and have experienced other failures that prevent recovery. These RAID-5 volumes must have their data restored. If any volumes (RAID-5 or otherwise) were rendered unusable, the following message is also included: To restore the contents of any volumes listed above, the volume should be started with the command: vxvol -f start volumename and the data restored from backup. Sparelist File The sparelist file is a text file that specifies an ordered list of disks to be used as hot spares when a specific disk fails. The system- wide sparelist file is located in /etc/vx/sparelist. Each line in the sparelist file specifies a list of spares for one disk. Lines beginning with the pound (#) character and empty lines are ignored. The format for a line in the sparelist file is: [ diskgroup:] diskname : spare1 [ spare2 ... ] The diskgroup field, if present, specifies the disk group within which the disk and designated spares reside. If this field is not speci- fied, the default disk group is determined using the rules given in the vxdg(1M) manual page. The diskname specifies the disk for which spares are being designated. The spare list after the colon lists the disks to be used as hot spares. The list is order dependent; in case of failure of diskname, the spares are tried in order. A spare will be used only if it is a valid hot spare (see above). If the list is exhausted without finding any spares, the default policy of using the closest disk is used. FILES
/etc/vx/sparelist Specifies a list of disks to serve as hot spares for a disk. NOTES
The sparelist file is not checked in any way for correctness until a disk failure occurs. It is possible to inadvertently specify a non- existent disk or inappropriate disk or disk group. Malformed lines are also ignored. SEE ALSO
mailx(1), vxintro(1M), vxnotify(1M), vxrecover(1M), vxrelocd(1M), vxunreloc(1M) VxVM 5.0.31.1 24 Mar 2008 vxsparecheck(1M)