Sponsored Content
Operating Systems Solaris True or false ? - Sun cluster 3.2 U3 questions... Post 302379440 by DukeNuke2 on Thursday 10th of December 2009 04:59:26 PM
Old 12-10-2009
Quote:
Originally Posted by erice
In what context does SC require SVM? That seems hard to believe.
you need some kind of volume managment if you use hastorage. so it is vxvm, svm or zfs. if you don't switch storage from one node to another you won't need volume management...
 

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Interesting TCL behavior: 007 == 7 is true; 008==8 is false.

Hi all, If anyone has the explanation for the following issue, please share it with me. I am comparing two variable a and b with the values of 007 and 7, for these values it get evaluated as True. For a=008 and b=8, for these values it get evaluated as false. #!/bin/tclsh set a 007 ... (3 Replies)
Discussion started by: sarwan
3 Replies

2. High Performance Computing

SUN Cluster Vs Veritas Cluster

Dear All, Can anyone explain about Pros and Cons of SUN and Veritas Cluster ? Any comparison chart is highly appreciated. Regards, RAA (4 Replies)
Discussion started by: RAA
4 Replies

3. HP-UX

Serviceguard Cluster Questions..

Hi, I'm fairly new to HP-UX. I am trying to find out if it is possible to create a cluster with 3 active nodes and 1 passive node. Everything I have found online so far just describes active/active and active/passive. Is it possible to have 3 active nodes and 1 passive node in a cluster? If... (2 Replies)
Discussion started by: DtbCollumb
2 Replies

4. Solaris

scconf crash: registering a Veritas local disk on Sun Cluster (localonly=true)

Hi all, I want to put a local disk on a Sun Cluster node but scconf command explodes :eek: My system: * two node cluster on two VMWare virtual machines * Solaris 10 SunOS 5.10 Generic_141415-05 i86pc i386 i86pc * Sun Cluster 3.2 u2 * Veritas Volume manager The situation... (2 Replies)
Discussion started by: gxmsgx
2 Replies

5. Solaris

Solaris cluster few questions

Today I downloaded Sun Cluster and I want to know more from someone experinced how much good is it that toy. Yes I also downloaded a documentation and I will read it but I want to know your experience so shoot . Probaly Jillagre has a few good stories . (1 Reply)
Discussion started by: solaris_user
1 Replies

6. Solaris

Sun Cluster

Hi All I hav working knowledge on solarois 10. Could anyone suggest me any doc or material for learning SUN cluster from scratch. Anything from basic level . Thanks in advance!! (1 Reply)
Discussion started by: ningy
1 Replies

7. Solaris

Sun cluster and Veritas cluster question.

Yesterday my customer told me to expect a vcs upgrade to happen in the future. He also plans to stop using HDS and move to EMC. Am thinking how to migrate to sun cluster setup instead. My plan as follows leave the existing vcs intact as a fallback plan. Then install and build suncluster on... (5 Replies)
Discussion started by: sparcguy
5 Replies

8. Solaris

Sun cluster 4.0 - zone cluster failover doubt

Hello experts - I am planning to install a Sun cluster 4.0 zone cluster fail-over. few basic doubts. (1) Where should i install the cluster s/w binaries ?. ( global zone or the container zone where i am planning to install the zone fail-over) (2) Or should i perform the installation on... (0 Replies)
Discussion started by: NVA
0 Replies

9. UNIX for Dummies Questions & Answers

Output checker setting variable to TRUE or FALSE

Hi All, I'm trying to come up a way to check the output of some data i have. I need to be able to check for the order of the output and if its correct set a variable to false if it isnt. Currently the data is in the below format, this is the value which should cause the variable be set... (4 Replies)
Discussion started by: mutley2202
4 Replies
pfto(7) 						 Miscellaneous Information Manual						   pfto(7)

NAME
pfto - Powerfail Timeout DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time- out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below). If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt. pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device. The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands display the current pfto value for a disk. EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01: vxdisk -g rootdg set disk01 pfto=30 Use either of the following commands to display the pfto value on the VxVM disk disk01: vxdisk list disk01 vxprint -l disk01 EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error. SEE ALSO
vxdisk(1M), vxprint(1M) VxVM 5.0.31.1 24 Mar 2008 pfto(7)
All times are GMT -4. The time now is 06:04 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy