12-09-2009
wfavorite I really appresiate your link :-) thanks a lot :-)
10 More Discussions You Might Find Interesting
1. AIX
hi,
i tried to mount using
$ mount nimsrv01:/export/mksysb_dev/VDEVVIO1 /mksysb
in vios mode.
i got following error..
</code>
Some error messages may contain invalid information
for the Virtual I/O Server environment.
mount: 1831-008 giving up on:... (1 Reply)
Discussion started by: honeym210
1 Replies
2. AIX
Hello, I'm having troubles running scripts on the VIOS. I want to run a simple script like:
lsmap -all | grep vhost
I've created the file with just like this:
$ cat script1.sh
lsmap -all | grep vhost
When I run the script, it returns the following error message:
script1.sh:... (5 Replies)
Discussion started by: enzote
5 Replies
3. AIX
I would like to hear your opinions, comments, pros and cons about the IVE (Integrated virtual ethernet) and VIOS (virtual i/o server)
With the VIOS can create virtual ethernet and virtual disk
With the IVE I dont need to create the vios and I can have virtual ethernet (physical and logical... (3 Replies)
Discussion started by: lo-lp-kl
3 Replies
4. AIX
Dear friends.. Will it be OK if I backup VIO Server Using smit mksysb?? will it save all virtual host mapings etc...??? thanks in advance (3 Replies)
Discussion started by: Vit0_Corleone
3 Replies
5. AIX
Hi, I would like to ask you if you could help me to answer these questions. Please.
How to check in vios, size all pv's and to what they are mapped to?
How to chech on vios/hmc which PowerVM edition is used?
Thank you. (7 Replies)
Discussion started by: phobus
7 Replies
6. AIX
Hello,
Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2.
What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies
7. AIX
I have 4 VIO server. I have to take backup of VIOS. I got the command "backupios" for taking the backup.
My question is if i am taking "backupios -tape /dev/rmt0 " whether it will take rootvg and all the user defined VG / File system which are using for virtual disk for client lpar.
I... (4 Replies)
Discussion started by: sunnybee
4 Replies
8. AIX
Hello,
I would like to create new lpar , but first i need to create a vhost to associate with it, does anyone know how to create vhost and associate it with lpar?
Thanks in advance (1 Reply)
Discussion started by: prpkrk
1 Replies
9. AIX
Hi,
$ ioslevel
2.2.4.10
I always get these errors when I perform any action using the web interface of IVM / VIOS
Shutdown Partitions Help
You have chosen to shutdown the following partitions. The recommended shutdown method is to use the client operating systems shutdown... (1 Reply)
Discussion started by: filosophizer
1 Replies
10. AIX
Hello,
In my environment, I have 2 VIOS. There is 1 lpar uses the first VIOS. Now we would like to move it to second VIOS.
My question is, can we migrate the virtual FC on the lpar to second VIOS?
If not, we have to create new virtual FC on second VIOS and map it to the lpar. This also... (3 Replies)
Discussion started by: Phat
3 Replies
LEARN ABOUT SUNOS
di_link_next_by_lnode
di_link_next_by_node(3DEVINFO) Device Information Library Functions di_link_next_by_node(3DEVINFO)
NAME
di_link_next_by_node, di_link_next_by_lnode - libdevinfo link traversal functions
SYNOPSIS
cc [ flag... ] file... -ldevinfo [ library... ]
#include <libdevinfo.h>
di_link_t di_link_next_by_node(di_lnode_t node, di_link_t link, uint_t endpoint);
di_link_t di_link_next_by_lnode(di_node_t lnode, di_link_t link, uint_t endpoint);
PARAMETERS
link The handle to the current the link or DI_LINK_NIL.
endpoint Specify which endpoint of the link the node or lnode should correspond to, either DI_LINK_TGT or DI_LINK_SRC.
node The device node with which the link is associated.
lnode The lnode with which the link is associated.
DESCRIPTION
The di_link_next_by_node() function returns a handle to the next link that has the same endpoint node as link. If link is DI_LINK_NIL, a
handle is returned to the first link whose endpoint specified by endpoint matches the node specified by node.
The di_link_next_by_lnode() function returns a handle to the next link that has the same endpoint lnode as link. If link is DI_LINK_NIL, a
handle is returned to the first link whose endpoint specified by endpoint matches the lnode specified by lnode.
RETURN VALUES
Upon successful completion, a handle to the next link is returned. Otherwise, DI_LINK_NIL is returned and errno is set to indicate the
error.
ERRORS
The di_link_next_by_node() and di_link_next_by_lnode() functions will fail if:
EINVAL An argument is invalid.
ENXIO The end of the link list has been reached.
The di_link_next_by_node() function will fail if:
ENOTSUP Device usage information is not available in snapshot.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Interface Stability |Evolving |
+-----------------------------+-----------------------------+
|MT-Level |Safe |
+-----------------------------+-----------------------------+
SEE ALSO
di_init(3DEVINFO), libdevinfo(3LIB), attributes(5)
SunOS 5.10 12 Jul 2004 di_link_next_by_node(3DEVINFO)