12-08-2009
Yes, I did reboot -r.
No, luns are not showing up. I can telnet to T3 storedge and there is no problem, but it is not visible from my solaris box. I just installed qlogick 2GB fiber card. I just want to make sure that it is intalled correctly. How can I verify?
10 More Discussions You Might Find Interesting
1. Solaris
I am using a SunBlade 1500 that currently runs Solaris 8 and I would like to install Solaris 10. This workstation has 1Gbyte of memory, 1 GigEthernet card and one 80Gbyte ATA drive. Soon a 2nd 80Gbyte drive will be installed.
Are there any 'interesting' points I need to watch for in the... (9 Replies)
Discussion started by: miket
9 Replies
2. UNIX for Advanced & Expert Users
Hello :) I have a customer who is OEMing their own hadware to us. The CPU is right out of a SunBlade 1500. Because of the physical requirements, the keyboard, DVD-ROM drive, 36GB Removable disk drive and scsi floppy are housed in what they call their media box which is in some cases 10 feet from... (0 Replies)
Discussion started by: rambo15
0 Replies
3. Solaris
I have a sunblade 100. It is preloaded with Solaris 8 but I do not have root password. I want to erase and install Solaris 9 on it. What are my options?
I have a CD ROM. Could any one help me in getting started to install in from CDs? Appreciate your help guyz. (3 Replies)
Discussion started by: stevelrf
3 Replies
4. UNIX for Dummies Questions & Answers
Hi,
My name is Mike and I am new here, perhaps the "1 post" gave me away,
I have a small problem. I know some very minor UNIX and VI and study hard to get better, this time I took upon myself a task just right above my level,
I hope to get two things out of this post
1) some advise to... (3 Replies)
Discussion started by: lawstudent
3 Replies
5. Solaris
I would like to know how to mount and acess USB flash memory /drive on sun blade 1500 operating solaris 8
thanks in advance (5 Replies)
Discussion started by: Blue_shadow
5 Replies
6. Solaris
Hi
I'm completely new in solaris,and don't know many about it.
I was installed solaris 10 on sun blade 1500,and also I need to install oracle on it.
Now I stuck on some thing and i'm sure that you help me.
When i started Oracle installation system told me that I don't have enogh swap space.... (1 Reply)
Discussion started by: dirtyjack
1 Replies
7. Solaris
Hi,
i have a two port hba card in solaris 10 system one of which is disabled. How to enable and configure the other port.
---------- Post updated at 08:17 AM ---------- Previous update was at 03:40 AM ----------
please help :( (7 Replies)
Discussion started by: rishiraaz
7 Replies
8. Hardware
Hi,
I bought a server Sunblade 1500, and I would like to install a nic card. Anyone know any compatible network card for this server?
Regards (1 Reply)
Discussion started by: ph0b0s
1 Replies
9. AIX
Hello,
I need to copy 1500+ files (total of 170mb) from our /tmp/directory to a different directory /application/program/files
I issue the command:
user@host> cp * /application/program/files
I am getting the follwing error:
ksh: /usr/bin/cp: arg list too long
being new to aix, I... (6 Replies)
Discussion started by: jeffs42885
6 Replies
10. UNIX Benchmarks
CPU/Speed: UltraSPARC-IIIi/1.5Ghz
Ram: 1GB
Motherboard: Sparc
Bus: PCI
Cache:
Controller:
Disk: ATA
Load: 1 user
Kernel: SunOS 5.10 Generic_137111-02
Kernel ELF?: yes
pgms: gcc 2.95.3 compiled
BYTE UNIX Benchmarks (Version 3.11)
System -- SunOS aachen95 5.10... (0 Replies)
Discussion started by: MadeInGermany
0 Replies
LEARN ABOUT HPUX
fcd_disable_mgmt_lun
fcd_disable_mgmt_lun(5) File Formats Manual fcd_disable_mgmt_lun(5)
NAME
fcd_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices
VALUES
Failsafe
Default
Allowed values
Enable discovery of management luns for array devices.
Disable discovery of management luns for array devices.
Recommended values
DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and
the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension
bus node. The entry for a legacy management lun looks like this:
On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual
extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns
requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of
management luns will free up virtual extension buses for use by data luns.
The default value for this tunable is
Who Is Expected to Change This Tunable?
System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device
special files.
Restrictions on Changing
Changes to this tunable take effect immediately. However, existing management luns will not be removed.
When Should the Tunable Be Turned On?
This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns.
What Are the Side Effects of Turning the Tunable Off?
None.
When Should the Tunable Be Turned Off?
When the functionality provided by the management lun is desired.
What Are the Side Effects of Turning the Tunable On?
Existing management luns in the legacy representation will show up in the state.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard Company.
SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M).
Tunable Kernel Parameters fcd_disable_mgmt_lun(5)