12-08-2009
They don't support anymore this hardware/software. You can get thier tech support if you buy a new line on what they are offering.
That's why i was thinking of just cloning the entire harddisk for me to have a backup.
So is there anyway, we can do it?
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hi,
i have to make an excect physical copie of a sun unix station harddisk.
I have to make all partitions the same on about 60 harddisks, and also they should contain the same data/info.
I have hade a look at commands 'DD' and 'UFSDUMP' but both of them are not sufficient enough.
Can... (5 Replies)
Discussion started by: dirk2
5 Replies
2. UNIX for Dummies Questions & Answers
hi friends,
one of my clnts wants his Hard drive to be ugrded . He is currently using SCO unix 5.04 on a 4.3 Gig SCSI drive. He wants me to upgrd it to 18 Gigs . All he wants is that the data / programs / userfiles shall be intact. he has 3 user slices /user1, /user2 , /user3 presently... (3 Replies)
Discussion started by: /etc/passwd
3 Replies
3. UNIX for Dummies Questions & Answers
i downloaded and burned the iso. the installation was pretty straight forward. evenything seemed alright.
however, after the install reboot, i get a "Data Access Exception" error and then the system exits to the "ok" prompt.
i tried finding something about this everywhere... but what i... (2 Replies)
Discussion started by: xyyz
2 Replies
4. UNIX for Dummies Questions & Answers
i know openbsd has a port that works on single cpu sparcs, and freebsd only works on the sparc64 architecture, and then there is netbsd that happens to work on multiprocessor sparc20's.
as far as i know these are the only free BSD's, are there any others that will work on a multiprocessor... (2 Replies)
Discussion started by: xyyz
2 Replies
5. Solaris
Hai ......... my name Rio,
I want to clone my harddisk at Sun Balade 2000 server with Solaris 8 OS, my question is :
a. what kind method for making backup or clonning disk ?
b. what method more easier , quick but still reliable ?
c. how to proceed it ?
Thanks (1 Reply)
Discussion started by: rioria
1 Replies
6. UNIX for Dummies Questions & Answers
hey guys this is my problem I have SCO unix installed on a IDE h/drive. I want to add a SCSI hard drive, how do i do that within UNIX (1 Reply)
Discussion started by: kwame.neilsen
1 Replies
7. Solaris
Hi all,
I am not sure I am in the correct forum or not, but I would appreciate if somebody from here can help me out.
My processing equipment currently is using Unltra5 SunOs 5.6 with 8.6 GB hard disk, newer UltraSPARC SunOS 5.8 is with higher hard disk capacity. I am wondering how much hard... (2 Replies)
Discussion started by: uvex
2 Replies
8. Solaris
Can i take image from all data in SCSI hard-disk which work in foxboro workstation and extract it again on another hard disk ?:b:
thanks (4 Replies)
Discussion started by: hatemeid
4 Replies
9. Solaris
It's a DHCP server. We want to make a clone for fail over purpose since there are some identical systems available here. We do have a secondary DHCP server.
Hardware: Sun v120. OS: Solaris 9. Two disks without array, /var and /opt on the secondary disk.
How can I clone the system via network... (1 Reply)
Discussion started by: aixlover
1 Replies
10. Shell Programming and Scripting
have three big data file, however I just need to see the mentioned below one line form the all the file which has SERVER_CONNECTION Value
File 1
export SERVER_CONNECTION=//dvlna002:10001/SmartServer
File2
export SERVER_CONNECTION=///SmartServer
File3
export... (1 Reply)
Discussion started by: Nsharma3006
1 Replies
CLONE(8) NUT Manual CLONE(8)
NAME
clone - UPS driver clone
NOTE
This man page only documents the specific features of the clone driver. For information about the core driver, see nutupsdrv(8).
DESCRIPTION
This driver, which sits on top of another driver socket, allows users to group clients to a particular outlet of a device and deal with
this output as if it was a normal UPS.
EXTRA ARGUMENTS
This driver supports the following settings:
load.off=command
Recommended. Set the command on the "real" UPS driver that will be used to switch off the outlet. You need both load.off and load.on in
order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT).
load.on=command
Recommended. Set the command on the "real" UPS driver that will be used to switch on the outlet. You need both load.off and load.on in
order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT).
load.status=value
Recommended. Set the variable on the "real" UPS driver that will be used to indicate the outlet status (i.e. on/off). If not specified,
the clone driver will attempt to keep track of the outlet status, but this is less reliable.
offdelay=num
Set the timer (in seconds) before the outlet is turned off after the shutdown condition (OB LB) for this outlet is met or a command to
shutdown was issued. Defaults to 120 seconds.
ondelay=num
Set the timer (in seconds) for the outlet to switch on in case the power returns after the oulet has been switched off. Defaults to 30
seconds.
mincharge=value
Set the remaining battery level when the clone UPS switches to LB (percent).
minruntime=value
Set the remaining battery runtime when the clone UPS switches to LB (seconds).
IMPLEMENTATION
The port specification in the ups.conf(5) reference the driver socket that the "real" UPS driver is using. For example:
[realups]
driver = usbhid-ups
port = auto
[clone-outlet-1]
driver = clone
port = usbhid-ups-realups
load.on = outlet.1.load.on
load.off = outlet.1.load.off
load.status = outlet.1.status
[...]
IMPORTANT
Unlike a real UPS, you should not configure a upsmon master for this driver. When a upsmon master sees the OB LB flags and tells the upsd
server it is OK to initiate the shutdown sequence, the server will latch the FSD status and it will not be possible to restart the systems
connected without restarting the upsd server.
This will be a problem if the power returns after the clone UPS initiated the shutdown sequence on it's outlet, but returns before the real
UPS begins shutting down. The solution is in the clone driver, that will insert the FSD flag if needed without the help of a upsmon master.
CAVEATS
The clone UPS will follow the status on the real UPS driver. You can only make the clone UPS shutdown earlier than the real UPS driver, not
later. If the real UPS driver initiates a shutdown, the clone UPS driver will immediately follow.
Be aware that the commands to shutdown/restart an outlet on the real UPS drivers are not affected, so if you tell the real UPS driver to
shutdown the outlet of the clone UPS driver, your clients will lose power without warning.
AUTHOR
Arjen de Korte <adkorte-guest@alioth.debian.org>
SEE ALSO
upscmd(1), upsrw(1), ups.conf(5), nutupsdrv(8)
Internet Resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 CLONE(8)