Sponsored Content
Full Discussion: Software RAID
Special Forums Hardware Filesystems, Disks and Memory Software RAID Post 302378324 by pludi on Monday 7th of December 2009 02:45:05 PM
Old 12-07-2009
Linux software RAID is usually managed through the mdadm tool. To see the status of the drives enter (replace /dev/md0 with the path to your actual RAID)
Code:
mdadm --detail /dev/md0

 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Software Raid - changed devices

Good Morning all, I just have a quick question, on some systems I am working with Software Raid Level 0 devices. Yes, I know, this is not a good idea, but it was requested :-( Now, due to a new requirement, I need to add a second internal disk to the system, but with adding the new disk,... (1 Reply)
Discussion started by: malcom
1 Replies

2. SuSE

Raid software besides Veritass

Hello Lunix people, I am looking for Raid software or solution besides Veritas. Veritas has some great software but are way too costly. Does anyone know of good raid software that but NOT Veritas. I need the funcations but not the cost. (7 Replies)
Discussion started by: xtmeisel
7 Replies

3. UNIX for Advanced & Expert Users

Software RAID ...

Hi all, I m just trying using software RAID in RHEL 4, without problem , then i wanna simulate if disk 1 is fail (thereis an bootloader), i plug off my 1st disk. My problems is the second disk cannot boot? just stuck in grub, the computer is hang. Sorry for poor concept in RAID? I use a RAID 1.... (0 Replies)
Discussion started by: blesets
0 Replies

4. HP-UX

Software RAID (0+1)

Hi! A couple of months ago a disk failed in our JBOD cabinett and I have finally got a new disk to replace it with. It was a RAID 0 so we have to create and configure the whole thing again. First we thought of RAID 1+0 but it seems you can't do this with LVM. If you read my last thread, you can... (0 Replies)
Discussion started by: hoff
0 Replies

5. Linux

Software RAID on Linux

Hey, I have worked with Linux for some time, but have not gotten into the specifics of hard drive tuning or software RAID. This is about to change. I have a Dell PowerEdge T105 at home and I am purchasing the following: 1GBx4 DDR2 ECC PC6400 RAM Rosewill RSV-5 E-Sata 5 bay disk enclosure... (6 Replies)
Discussion started by: mark54g
6 Replies

6. Red Hat

Software RAID doubt

hi friends, I am having issues with adding a spare device to a failed array. I have created RAID 1 with 3 partitions using mdadm command. Later I added a spare with mdadm --add /dev/md0 /dev/sdb6 This works fine and when I check this with mdadm --detail command it just sits there as a spare... (7 Replies)
Discussion started by: saagar
7 Replies

7. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

8. Red Hat

Software RAID configuration

We have configured software based RAID5 with LVM on our RHEL5 servers. Please let us know if its good to configure software RAID on live environment servers. What can be the disadvantages of software RAID against hardware RAID (4 Replies)
Discussion started by: mitchnelson
4 Replies

9. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies
CCDCONFIG(8)						    BSD System Manager's Manual 					      CCDCONFIG(8)

NAME
ccdconfig -- configuration utility for the concatenated disk driver SYNOPSIS
ccdconfig [-cv] ccd ileave [flags] dev ... ccdconfig -C [-v] [-f config_file] ccdconfig -u [-v] ccd ... ccdconfig -U [-v] [-f config_file] ccdconfig -g [ccd ...] DESCRIPTION
The ccdconfig utility is used to dynamically configure and unconfigure concatenated disk devices, or ccds. For more information about the ccd, see ccd(4). The options are as follows: -c Configure a ccd. This is the default behavior of ccdconfig. -C Configure all ccd devices listed in the ccd configuration file. -f config_file When configuring or unconfiguring all devices, read the file config_file instead of the default /etc/ccd.conf. -g Dump the current ccd configuration in a format suitable for use as the ccd configuration file. If no arguments are specified, every configured ccd is dumped. Otherwise, the configuration of each listed ccd is dumped. -u Unconfigure a ccd. -U Unconfigure all ccd devices listed the ccd configuration file. -v Cause ccdconfig to be verbose. A ccd is described on the command line and in the ccd configuration file by the name of the ccd, the interleave factor, the ccd configuration flags, and a list of one or more devices. The flags may be represented as a decimal number, a hexadecimal number, a comma-separated list of strings, or the word ``none''. The flags are as follows: CCDF_UNIFORM 0x02 Use uniform interleave CCDF_MIRROR 0x04 Support mirroring CCDF_NO_OFFSET 0x08 Do not use an offset CCDF_LINUX 0x0A Linux md(4) compatibility The format in the configuration file appears exactly as if it were entered on the command line. Note that on the command line and in the configuration file, the flags argument is optional. # # /etc/ccd.conf # Configuration file for concatenated disk devices # # ccd ileave flags component devices ccd0 16 none /dev/da2s1 /dev/da3s1 The component devices need to name partitions of type FS_BSDFFS (or ``4.2BSD'' as shown by disklabel(8)). If you want to use the Linux md(4) compatibility mode, please be sure to read the notes in ccd(4). FILES
/etc/ccd.conf default ccd configuration file EXAMPLES
A number of ccdconfig examples are shown below. The arguments passed to ccdconfig are exactly the same as you might place in the /etc/ccd.conf configuration file. The first example creates a 4-disk stripe out of four scsi disk partitions. The stripe uses a 64 sector interleave. The second example is an example of a complex stripe/mirror combination. It reads as a two disk stripe of da4 and da5 which is mirrored to a two disk stripe of da6 and da7. The last example is a simple mirror. The 2nd slice of /dev/da8 is mirrored with the 3rd slice of /dev/da9 and assigned to ccd0. # ccdconfig ccd0 64 none /dev/da0s1 /dev/da1s1 /dev/da2s1 /dev/da3s1 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da4 /dev/da5 /dev/da6 /dev/da7 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da8s2 /dev/da9s3 The following are matching commands in Linux and FreeBSD to create a RAID-0 in Linux and read it from FreeBSD. # Create a RAID-0 on Linux: mdadm --create --chunk=32 --level=0 --raid-devices=2 /dev/md0 /dev/hda1 /dev/hdb1 # Make the RAID-0 just created available on FreeBSD: ccdconfig -c /dev/ccd0 32 linux /dev/ada0s1 /dev/ada0s2 When you create a new ccd disk you generally want to fdisk(8) and disklabel(8) it before doing anything else. Once you create the initial label you can edit it, adding additional partitions. The label itself takes up the first 16 sectors of the ccd disk. If all you are doing is creating file systems with newfs, you do not have to worry about this as newfs will skip the label area. However, if you intend to dd(1) to or from a ccd partition it is usually a good idea to construct the partition such that it does not overlap the label area. For example, if you have A ccd disk with 10000 sectors you might create a 'd' partition with offset 16 and size 9984. # disklabel ccd0 > /tmp/disklabel.ccd0 # disklabel -Rr ccd0 /tmp/disklabel.ccd0 # disklabel -e ccd0 The disklabeling of a ccd disk is usually a one-time affair. If you reboot the machine and reconfigure the ccd disk, the disklabel you had created before will still be there and not require reinitialization. Beware that changing any ccd parameters: interleave, flags, or the device list making up the ccd disk, will usually destroy any prior data on that ccd disk. If this occurs it is usually a good idea to reini- tialize the label before [re]constructing your ccd disk. RECOVERY
An error on a ccd disk is usually unrecoverable unless you are using the mirroring option. But mirroring has its own perils: It assumes that both copies of the data at any given sector are the same. This holds true until a write error occurs or until you replace either side of the mirror. This is a poor-man's mirroring implementation. It works well enough that if you begin to get disk errors you should be able to backup the ccd disk, replace the broken hardware, and then regenerate the ccd disk. If you need more than this you should look into external hardware RAID SCSI boxes, RAID controllers (see GENERIC), or software RAID systems such as geom(8) and gvinum(8). SEE ALSO
dd(1), ccd(4), disklabel(8), fdisk(8), gvinum(8), rc(8) HISTORY
The ccdconfig utility first appeared in NetBSD 1.0A. BUGS
The initial disklabel returned by ccd(4) specifies only 3 partitions. One needs to change the number of partitions to 8 using ``disklabel -e'' to get the usual BSD expectations. BSD
October 1, 2013 BSD
All times are GMT -4. The time now is 10:52 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy