Sponsored Content
Operating Systems AIX AIX(VIO/LPAR) with Free NAS ISCSI solution Post 302377642 by kabir on Friday 4th of December 2009 02:09:14 PM
Old 12-04-2009
AIX(VIO/LPAR) with Free NAS ISCSI solution

Hi,

I was looking on Google for AIX-VIO/LPAR with ISCSI solution and found following really nice tutorial about how to setup ISCSI with free NAS.

1) Build Your Own Open Source NAS Device Using FreeNAS | Train Signal Training - Free Computer Training Videos

2) Build Your Own Open Source NAS Device Using FreeNAS - Part 2 | Train Signal Training - Free Computer Training Videos

After going through with this really impressive doc, I've decided to implement Free NAS with ISCSI but have some query.

- can AIX support Free NAS?
- Which are the Hardware (storage) available that supports AIX and Free NAS?
- is there anything required to setup on P520. (e.g. file sets, or add ISCSI adapter)

I'm really looking for ISCSI solution for AIX and if this is supported then its awesome solution to replace fiber base.

if anyone has implemented this or similar solutions , please guide.... I will highly appreciate.

Thanks!
 

10 More Discussions You Might Find Interesting

1. AIX

Restoring mksysb to vio lpar?

I have a standard template I deploy for each of my AIX servers. It's in a mksysb format which I pulled via the nim server after I originally set it up. I'm trying to restore this mksysb over the wire to a remote system. The remote system is an lpar running under vio (no HMC attached). The disk... (1 Reply)
Discussion started by: scottsl
1 Replies

2. UNIX for Dummies Questions & Answers

Unix VIO vs Dynamic LPAR

Can you have a Dynamic LPAR without VIO and if yes is there a benefit to having both? I am attempting to implement VIO and Resource pooling at my company and want to understand the limitations. Also, I have been told the managing and allocation of the Logical Volumes is a time consuming task as... (0 Replies)
Discussion started by: bombers73
0 Replies

3. AIX

LPAR and vio disk mapping

We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Discussion started by: daveisme
4 Replies

4. AIX

LPAR and AIX VIO Disk Mappring for Linux Clients

VIO Server is managing both AIX Clients and Linux Clients. For AIX Clients, we could do a disk mapping from slot numbers to VIO and also uname -L to determine the lparid and serial number frame its running on. From a Linux Client, How do I know which IBM frame its running on? Any command to... (4 Replies)
Discussion started by: rpangulu
4 Replies

5. AIX

LPAR - What is my VIO (hostname, IP, ...)

I am wondering if there is a command I can run from **with-in** LPAR server (server01) to find out the hostname or IP address or other parameters for VIO server in charge of server01? (1 Reply)
Discussion started by: ms1232
1 Replies

6. AIX

Possible to connect a LPAR to two different VIO's?

Just a question which may seem dumb to some out there, but then again I am not a super technie so that's my excuse. Is it possible to say provision a test AIX LPAR (has a 10gb boot lun and 20gb data) under a VIO which has connectivity to SAN Array A so it can see the disks provisioned to it,... (2 Replies)
Discussion started by: Johnny1314
2 Replies

7. AIX

A solution to the mkvg failure when adding iSCSI disks to AIX.

Previous forum threads have noted that AIX cannot use iSCSI disks because it fails when trying to add them to a volume group using mkvg. The failure is caused by AIX's use of the SCSI "WRITE AND VERIFY"(0x2e) command which some iSCSI targets do not support. We experienced the same problem using... (1 Reply)
Discussion started by: garethr
1 Replies

8. AIX

VIO server does not show new LPAR

Hi All, I've been trying to create a new LPAR for some days now but I can't get the VIO server to recognize the new LPAR. This is what I did: On HMC create new LPAR On HMC create new virtual scsi adapter for LPAR in VIO profile On HMC add new virtual scsi adapter for LPAR with DLPAR... (6 Replies)
Discussion started by: petervg
6 Replies

9. Linux

FC, iSCSI, and NAS configuration?

I am using Windows Server 2008R2 as a domain controller to 2 other servers and would like to use my Dell Powervault 770N as my NAS for data storage. I have FC that I would like to implement between the servers and the NAS (as an iSCSI target). I am brand new to this world; is this possible? I am... (2 Replies)
Discussion started by: NoviceAdmin
2 Replies

10. AIX

VIO and LPAR disk/fcs communications

:wall::wall::wall: 1. I have created an LPAR in the HMC. 2. I have allocated the storage from an Hitachi AMS2500 and assigned it to the host group. 3. I have zoned the LPAR and Storage on a Brocade 5100. (The zone sees the AMS) Next I activated the LPAR in the HMC, SMS mode for the mksysb... (3 Replies)
Discussion started by: Dallasguy7
3 Replies
ISCSI.CONF(5)							File Formats Manual						     ISCSI.CONF(5)

NAME
iscsi.conf - iSCSI Target and LUN configuration SYNOPSIS
/etc/iscsi.conf DESCRIPTION
This manual page describes the format of the /etc/iscsi.conf file. This file is a simple text file that iscsid(8) uses to locate iSCSI tar- get devices and LUNs. Comments are marked by lines beginning with '#'. Available entries include: DiscoveryAddress=<address> IP address or hostname to use for target discovery. A TCP port number may be specified by appending a colon followed by the port number. This entry must start in the first column, and must not contain any whitespace. TargetIpAddr=<address> A synonym for DiscoveryAddress. Username=<user> Specify the authentication user. If this entry precedes all DiscoveryAddress entries, it serves as the default. If this entry is indented under a DiscoveryAddress entry, it specifies the user for all targets discovered at that IP address. Password=<pass> Specify the authentication password for the previously listed iSCSI If this entry precedes all DiscoveryAddress entries, it serves as the default. If this entry is indented under a DiscoveryAddress entry, it specifies the user for all targets discovered at that IP address. EXAMPLE
# set the default user and password Username=alice Password=nty57nbe # targets at this address will use the default Username and Password DiscoveryAddress=192.168.10.94 # targets at this address will use the Username and Password below DiscoveryAddress=192.168.10.95 Username=beatrice Password=93fdgc20 NOTES
The iSCSI initiator drivers, README files, and example configuration files are available on the Linux-iSCSI homepage at: http://linux-iscsi.sourceforge.com <http://linux-iscsi.sourceforge.com> FILES
/etc/iscsi.conf iSCSI Target and LUN configuration SEE ALSO
iscsid(8) $Revision: 1.9 $ $Date: 2002/09/19 20:00:32 $ ISCSI.CONF(5)
All times are GMT -4. The time now is 12:36 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.