Operating Systems Solaris CPU Temperature Details Post 302376266 by DukeNuke2 on Tuesday 1st of December 2009 04:47:50 AM
Old 12-01-2009
you have to give "username" and "password" in the statement...
 

9 More Discussions You Might Find Interesting

1. HP-UX

temperature records

I'm fairly new to hpux, so this is what i've been trying to figure out. Is it possible to get any logs on hpux that would indicate if the system, cpu, or other hardware components reached above normal or critical temperatures? Thanks, -K (0 Replies)
Discussion started by: uzerx
0 Replies

2. Solaris

E450 CPU temperature 80 degree F

Hi all, We are getting CPU warning temeratures sometimes and our server is shutdown at 80 degree F. We notice our server room temperature at 18 degree celcius . Our we have already cleaned dust from grills near CPU Fan . CPU fans are working (moving) . It is our experience that CPU... (5 Replies)
Discussion started by: Hitesh Shah
5 Replies

3. Solaris

CPU temperature

Hi all I have a SUN V480 server with 4 processores and I've noticed that the temperature for 2 of the 4 processers are quite high (63 degrees Celsius). Does anyone know what the operating temperatures of the Sparc CPU's are? I'm not getting any warning messages yet, but I want to resolve the... (3 Replies)
Discussion started by: soliberus
3 Replies

4. Solaris

How to change CPU threshold high temperature

Hi, I have a NETRA 240 server wich should work on high temperature environment (up to 50 deg celsius). After reaching ~48 deg, the system is shuting down. The HighShutDownThreshold of the CPU is set to 89 deg The PowerOffThreshold of the CPU is set to 96 deg Please help me to change these... (2 Replies)
Discussion started by: Danielz
2 Replies

5. UNIX for Advanced & Expert Users

Script to access multiple linux servers to get system details such as CPU usage

Hi Is there any shell script that accesses multiple linux servers to get details such as CPU usage, RAM used etc. The access of the servers must be parallel not serial in the sense it must ping all the servers at a time to get information.The script has to be triggered from a host system and get... (7 Replies)
Discussion started by: mssrivatsa
7 Replies

6. Solaris

How to read CPU temperature?

Hello all, I am using prtdiag -v command to find the temperature sensors . And i dont see the following o/p . ystem Configuration: Hewlett-Packard HP Z400 Workstation BIOS Configuration: Hewlett-Packard 786G3 v01.17 08/19/2009 ==== Processor Sockets ==================================== ... (2 Replies)
Discussion started by: b.preeya22
2 Replies

7. UNIX for Advanced & Expert Users

UNIX / LINUX OS CPU configuration details

Hi, How to find the cpu configuration details of Cores, Speed MHz, virtual processors for the following servers: LINUX OS Servers: Linux 2.6.9-89.0.3.ELsmp #1 SMP Sat Jun 13 07:05:54 EDT 2009 i686 i686 i386 GNU/Linux. (Cores, Speed, Processor) Linux 2.6.18-164.el5 #1 SMP Tue Aug 18... (5 Replies)
Discussion started by: jagtheesh
5 Replies

8. UNIX for Dummies Questions & Answers

at -l doesnt give details of the scheduled job. How to get the details?

I have scheduled couple of shell scripts to run using 'at' command. The o/p of at -l is: $ at -l 1320904800.a Thu Nov 10 01:00:00 2011 1320894000.a Wed Nov 9 22:00:00 2011 1320876000.a Wed Nov 9 17:00:00 2011 $ uname -a SunOS dc2prcrptetl2 5.9 Generic_122300-54 sun4u sparc... (2 Replies)
Discussion started by: superparticle
2 Replies

9. Hardware

Max CPU temperature?

What is the max operating temperature for 'UltraSPARC IIIi 1 GHz' ? thanks. (1 Reply)
Discussion started by: orange47
1 Replies
AMDTEMP(4)						   BSD Kernel Interfaces Manual 						AMDTEMP(4)

NAME
amdtemp -- device driver for AMD K8, K10 and K11 on-die digital thermal sensor SYNOPSIS
To compile this driver into the kernel, place the following line in your kernel configuration file: device amdtemp Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): amdtemp_load="YES" DESCRIPTION
The amdtemp driver provides support for the on-die digital thermal sensor present in AMD K8, K10 and K11 processors. For the K8 family, the amdtemp driver reports each cores' temperature through a sysctl node in the corresponding CPU devices's sysctl tree, named dev.amdtemp.%d.sensor{0,1}.core{0,1}. The driver also creates dev.cpu.%d.temperature displaying the maximum temperature of the two sensors located in each CPU core. For the K10 and K11 families, the driver creates dev.cpu.%d.temperature with the temperature of each core. BUGS
AMD K9 is not supported because temperature reporting has been replaced by Maltese. SEE ALSO
sysctl(8) HISTORY
The amdtemp driver first appeared in FreeBSD 7.1. AUTHORS
Rui Paulo <rpaulo@FreeBSD.org> Norikatsu Shigemura <nork@FreeBSD.org> BSD
April 8, 2008 BSD
All times are GMT -4. The time now is 11:36 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy