Sponsored Content
Operating Systems SCO Dell PowerEdge 2600 tape backup Post 302374524 by ezlarry on Tuesday 24th of November 2009 07:18:56 PM
Old 11-24-2009
Many thanks for the complete and fast reply!

This production system has not been available for me to reboot and view post messages. Would the post messages also be logged in /usr/adm/messages ? (I forgot to look there)

---------- Post updated at 06:18 PM ---------- Previous update was at 06:14 PM ----------

I was prepared to carry out the mkdev tape operation, but was not able to since I could not reboot the production system. But I have a question about the procedure I found as (shown below): does mkdev tape perform the re-link since it rebuilds the kernel?

# mkdev tape
Pick 1) Install a Tape Drive
Pick 4) Install SCSI Tape Drive
Pick Yes Do you wish to configure the SCSI Tape Drive now? (y/n?)
Pick 0-7 What is the ID of the controller for this device?
Pick 0 or 1 Which SCSI host adapter supports this device?
Pick 0 What is the LUN of this device? Always enter 0 for the LUN.

You will then see:
The following special devices have been created:
/dev/rStp# /dev/nrStp# /dev/xStp#
Press <Return> to Continue.

The original Tape Drive Configuration Program menu will then be displayed.
Press "q" to quit and you will be asked:

You must create a new kernel to affect the driver change you specified.
Do you wish to create a new kernel now? (y/n)

Choose "y" and you will see the message:

The UNIX Operating System will now be rebuilt.
This is take a few minutes. Please wait.

Root for this system build it /.

This will take a few minutes and then you will be asked:

Do you want this kernel to boot by default? (y/n)

Again, answer "y".

Next you will be asked:

Do you want the kernel environment rebuilt? (y/n)

Again, answer "y".

When you receive a root prompt, shut the system down and reboot to
activate the new kernel.

You are now ready to use your tape drive.
 

8 More Discussions You Might Find Interesting

1. Linux Benchmarks

Dell Dual Xeon PowerEdge 4600

Notes: System Configuration: Dell Computer Corporation PowerEdge 4600 (4 X Intel(R) XEON(TM) CPU 2.00GHz 1988.782 MHz) hyperthreaded System clock frequency: 99.0827 MHz Memory size (approximate): 2559 Megabytes ========================= CPUs ======================== CPU # CPU... (0 Replies)
Discussion started by: tnorth
0 Replies

2. Linux Benchmarks

Dell Poweredge 2400 / 533

CPU/Speed: Dual PIII 533 Ram: 256Mb PC133 Motherboard: Unknown, Intel Chipset Cache: 256k on board Controller: PARC Raid 2/Si, AIC-7880U Disk: 30Gb RAID 5 Load: 1 user. Clean boot, init 5 but X-Windows not loaded. Kernel: See Benchmarks. pgms: gcc 3.2.3 ... (2 Replies)
Discussion started by: Garp
2 Replies

3. Solaris

Installing Solaris 10 on Dell PowerEdge 2800

hi, i am trying to install solaris 10 (on 4 cd's downloaded from the sun website) on my dell poweredge 2800 server. 2 xeon processors, 2GB of RAM and 2 NICS, 73 GB SCSI (maxtor ultra320, 3.5 series), i can give more details on request... the installation crashes when trying to detect the NICS... (0 Replies)
Discussion started by: xinugeek
0 Replies

4. Red Hat

Installing RedHat 8.0 onto Dell PowerEdge SC1425 - hdc: status error: status = 0x58

I have successfully installed RedHat 8.0 onto a Dell PowerEdge SC1425 today. This server has two SATA hard drives, and an IDE DVD-ROM drive. Using the following kernel parameters, i successfully installed across both hard drives from CD: ide0=0x1f0,0x3f6,14 vga=791 resolution=1024x768 expert... (5 Replies)
Discussion started by: fishsponge
5 Replies

5. Filesystems, Disks and Memory

Linux and Dell 1500sc Poweredge Server

Does anybody no how to get around the fact that the Red Hat installation does not see the SCSI hard drives. It lets you manually pick the proper device, but still fails saying no drive detected (or something to that effect). I was going to install windows 2003 Server and use VMware...but again,... (1 Reply)
Discussion started by: Fatflea
1 Replies

6. UNIX for Dummies Questions & Answers

Stange problem Dell PowerEdge 1950/ Boradcom Netextreme NIC

I have 2 Dell Poweredge 1950 servers running . I have been having intermittent performance issues with the NIC cards on one of them. The two servers are identical and are running the same operating system. The server that has the issue is on the DMZ on a a static IP and is hosting a website. ... (0 Replies)
Discussion started by: skotapal
0 Replies

7. SCO

Continueing relyability problems with SCO 6.0 on Dell Poweredge 1800 with PERC DC4.

Hello all, I'am experiencing weird relyability problems with a SCO 6.0 Openserver server that runs on a Dell Poweredge 1800 equipped with a PERC DC4 raid controller and 4 36 GB 15 K rpm hot swappable scsi harddisks. It runs a RAID 10 configuration. It uses the mega hba, Revision 8.03a Release... (1 Reply)
Discussion started by: frederik1
1 Replies

8. Programming

/dev/mem on Dell Poweredge

Hi, I have a C++ program to access /dev/mem and retrieve details like Vendor, Manufacturer details of the motherboard. This works fine on all the machines except for on Dell Poweredge 2850,1950... machines. I receive a 'EFAULT' when I try to access /dev/mem on these servers. I suspect some... (1 Reply)
Discussion started by: ragisreekanth
1 Replies
backup(1M)																backup(1M)

NAME
backup - backup or archive file system SYNOPSIS
[-archive] DESCRIPTION
The command uses find(1) and cpio(1) to save a archive of all files that have been modified since the modification time of on the default tape drive should be invoked periodically to ensure adequate file backup. The option suppresses warning messages regarding optional access control list entries. backup(1M) does not backup optional access control list entries in a file's access control list (see acl(5)). Normally, a warning message is printed for each file having optional access control list entries. The option causes backup to save all files, regardless of their modification date, and then update using touch(1). prompts you to mount a new tape and continue if there is no more room on the current tape. Note that this prompting does not occur if you are running from cron(1M). The option causes to start a file system consistency check (without correction) after the backup is complete. For correct results, it is important that the system be effectively single-user while is running, especially if is allowed to automatically fix whatever inconsisten- cies it finds. does not ensure that the system is single-user. You can edit to customize it for your system. Several local values are used that can be customized: specifies which directories to back up recursively (usually meaning all directories); file name where start and finish times, block counts, and error messages are logged; file name whose date is the date of the last archive; file name that is checked by to remind the next person who logs in to change the backup tape; file name where start and finish times and output is logged. You may want to make other changes, such as whether or not does automatic correction (according to its arguments), where output is directed, other information logging, etc. In all cases, the output from is a normal archive file (or volume) which can be read using with the option. File Recovery creates archive tapes with all files and directories specified relative to the root directory. When recovering files from an archive tape created by you should be in the root directory and specify the directory path names for recovered files relative to the root directory When specifying the directory path name for file recovery by do not precede the leading directory name with a slash. If you prefer, you can also use with a option to determine how files and directories are named on the archive tape before attempting recovery. WARNINGS
Refer to in cpio(1). When runs out of tape, it sends an error to standard error and demands a new special file name from To continue, rewind the tape, mount the new tape, type the name of the new special file at the system console, and press If is being run unattended from cron(1M) and the tape runs out, terminates, leaving the process still waiting. Kill this process when you return. FILES
parameterized file names SEE ALSO
cpio(1), find(1), touch(1), cron(1M), fbackup(1M), frecover(1M), fsck(1M), acl(5). backup(1M)
All times are GMT -4. The time now is 10:04 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy