Sponsored Content
Operating Systems HP-UX [Joy Share] - Replace an unknown status controller on HP FC60 disk array Post 302374401 by vbe on Tuesday 24th of November 2009 11:00:39 AM
Old 11-24-2009
Not sure I understood...
If you were thinking of High availability capacities, though I dont dont know how (I always used XP/HDS subsystems...) it can be done If you believe (extract...):
Quote:
For high availability the hosts and disk arrays can be connected in any of the following
ways, with each connection of adapter and controller module creating a separate 2-node
Fibre Channel-AL:
• One disk array with two controller modules with each controller module connected to
a separate adapter in a single host
from http://h20000.www2.hp.com/bc/docs/su...5/lpg28375.pdf
page 104.
 

10 More Discussions You Might Find Interesting

1. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

2. Shell Programming and Scripting

test: unknown operator status

hi I get test: unknown operator status if then echo "OK." return 0 else echo "not ok" 2>&1 exit -1 fi I tried to change "A" with 'A' --> same error I tried to change if , I am getting: (3 Replies)
Discussion started by: melanie_pfefer
3 Replies

3. SCO

Warning HD: no root disk controller was found

hi... i hav a problem to install sco unix while installing sco unix 5.0.5 in acer altos with hardware raid am getting error "Warning HD: no root disk controller was found system error 5: while getting fs type flushing controller: DAC960PRL cache done." i hav use the following... (18 Replies)
Discussion started by: mselvaprakash
18 Replies

4. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

5. Solaris

Help needed to find out the disk controller for veritas disks

hi all i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output # vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online... (2 Replies)
Discussion started by: kingston
2 Replies

6. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

7. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

8. Solaris

SUN 6540 Array with failed controller battery

Can someone point me to a procedure detailing the replacement of a failed battery in a SUN 6540 controller. Or describe the procedure. Thanks (1 Reply)
Discussion started by: USFE
1 Replies

9. Solaris

Disk controller reassignment

Hi The scenario in the oracle t4-1 hardware with solaris 10 is as follows: 1. The initial install on the server was performed with an incorrect disk layout. 2. New disks were ordered and slot into the server. 3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies

10. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies
MLX(4)                                                     BSD Kernel Interfaces Manual                                                     MLX(4)

NAME
mlx -- Mylex DAC-family RAID driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device mlx Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): mlx_load="YES" DESCRIPTION
The mlx driver provides support for Mylex DAC-family PCI to SCSI RAID controllers, including versions relabeled by Digital/Compaq. HARDWARE
Controllers supported by the mlx driver include: o Mylex DAC960P o Mylex DAC960PD / DEC KZPSC (Fast Wide) o Mylex DAC960PDU o Mylex DAC960PL o Mylex DAC960PJ o Mylex DAC960PG o Mylex DAC960PU / DEC PZPAC (Ultra Wide) o Mylex AcceleRAID 150 (DAC960PRL) o Mylex AcceleRAID 250 (DAC960PTL1) o Mylex eXtremeRAID 1100 (DAC1164P) o RAIDarray 230 controllers, aka the Ultra-SCSI DEC KZPAC-AA (1-ch, 4MB cache), KZPAC-CA (3-ch, 4MB), KZPAC-CB (3-ch, 8MB cache) All major firmware revisions (2.x, 3.x, 4.x and 5.x) are supported, however it is always advisable to upgrade to the most recent firmware available for the controller. Compatible Mylex controllers not listed should work, but have not been verified. DIAGNOSTICS
Controller initialisation phase mlx%d: controller initialisation in progress... mlx%d: initialisation complete The controller firmware is performing/has completed initialisation. mlx%d: physical drive %d:%d not responding The drive at channel:target is not responding; it may have failed or been removed. mlx%d: spinning up drives... Drive startup is in progress; this may take several minutes. mlx%d: configuration checksum error The array configuration has become corrupted. mlx%d: mirror race recovery in progress mlx%d: mirror race on a critical system drive mlx%d: mirror race recovery failed These error codes are undocumented. mlx%d: physical drive %d:%d COD mismatch Configuration data on the drive at channel:target does not match the rest of the array. mlx%d: system drive installation aborted Errors occurred preventing one or more system drives from being configured. mlx%d: new controller configuration found The controller has detected a configuration on disk which supersedes the configuration in its nonvolatile memory. It will reset and come up with the new configuration. mlx%d: FATAL MEMORY PARITY ERROR Firmware detected a fatal memory error; the driver will not attempt to attach to this controller. mlx%d: unknown firmware initialisation error %x:%x:%x An unknown error occurred during initialisation; it will be ignored. Driver initialisation/shutdown phase: mlx%d: can't allocate scatter/gather DMA tag mlx%d: can't allocate buffer DMA tag mlx%d: can't allocate s/g table mlx%d: can't make initial s/g list mapping mlx%d: can't make permanent s/g list mapping mlx%d: can't allocate interrupt mlx%d: can't set up interrupt A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. mlx%d: error fetching drive status The current status of all system drives could not be fetched; attachment of system drives will be aborted. mlx%d: device_add_child failed mlx%d: bus_generic_attach returned %d Creation of the system drive instances failed; attachment of one or more system drives may have been aborted. mlxd%d: detaching... The indicated system drive is being detached. mlxd%d: still open, can't detach The indicated system drive is still open or mounted; the controller cannot be detached. mlx%d: flushing cache... The controller cache is being flushed prior to detach or shutdown. Operational diagnostics: mlx%d: ENQUIRY failed - %s mlx%d: ENQUIRY2 failed mlx%d: ENQUIRY_OLD failed mlx%d: FLUSH failed - %s mlx%d: CHECK ASYNC failed - %s mlx%d: REBUILD ASYNC failed - %s mlx%d: command failed - %s The controller rejected a command for the reason given. mlx%d: I/O beyond end of unit (%u,%d > %u) mlx%d: I/O error - %s An I/O error was reported by the controller. mlx%d: periodic enquiry failed - %s An attempt to poll the controller for status failed for the reason given. mlx%d: mlx_periodic_enquiry: unknown command %x The periodic status poll has issued a command which has become corrupted. mlxd%d: drive offline mlxd%d: drive online mlxd%d: drive critical The system disk indicated has changed state. mlx%d: physical drive %d:%d reset mlx%d: physical drive %d:%d killed %s mlx%d: physical drive %d:%d error log: sense = %d asc = %x asq = %x mlx%d: info %4D csi %4D The drive at channel:target has been reset, killed for the given reason, or experienced a SCSI error. mlx%d: unknown log message type %x mlx%d: error reading message log - %s An error occurred while trying to read the controller's message log. mlxd%d: consistency check started mlx%d: consistency check completed A user-initiated consistency check has started/completed. mlx%d: drive rebuild started for %d:%d mlx%d: drive rebuild completed A user-initiated physical drive rebuild has started/completed. mlx%d: background check/rebuild operation started mlx%d: background check/rebuild operation completed An automatic system drive consistency check or physical drive rebuild has started/completed. mlx%d: channel %d pausing for %d seconds mlx%d: channel %d resuming mlx%d: pause command failed - %s mlx%d: pause failed for channel %d mlx%d: resume command failed - %s mlx%d: resume failed for channel %d Controller/channel pause operation notification. (Channel pause is not currently supported on any controller.) mlx%d: controller wedged (not taking commands) The controller is not responding to attempts to submit new commands. mlx%d: duplicate done event for slot %d mlx%d: done event for nonbusy slot %d Corruption has occurred in either the controller's onboard list of commands or in the driver. SEE ALSO
mlxcontrol(8) AUTHORS
The mlx driver was written by Michael Smith <msmith@FreeBSD.org>. This manual page was written by Jeroen Ruigrok van der Werven <asmodai@FreeBSD.org> and Michael Smith <msmith@FreeBSD.org>. BUGS
The driver does not yet support EISA adapters. The DEC KZPSC has insufficient flash ROM to hold any reasonably recent firmware. This has caused problems for this driver. The driver does not yet support the version 6.x firmware as found in the AcceleRAID 352 and eXtremeRAID 2000 and 3000 products. BSD August 10, 2004 BSD
All times are GMT -4. The time now is 07:10 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.