Sponsored Content
Operating Systems HP-UX Software management HP/UX 9.00 Post 302366756 by vbe on Friday 30th of October 2009 09:31:00 AM
Old 10-30-2009
What do you call software management?
Thats at least 12 years I havent touched a HPUX 9... (I liked alot for LVM was introduced in this version (I worked on 9.04 essentially...)
 

4 More Discussions You Might Find Interesting

1. IP Networking

Network Management Software

We are a small legal firm in the UK and looking to upgrade from some open source network management tools we are using. I'm not finding very many commercially supported network management software solutions that run on Linux or UNIX for that matter. Does anyone have any recommendations? ... (2 Replies)
Discussion started by: ctrenton
2 Replies

2. AIX

AIX software management problem

Hi to all please help ...Acutally i m new in AIX. I dont much know about AIX. I m totally confusing with software management chapter. Actually i m not getting difference between. LPP,,BUNDLE,,,PACKAGE,,FIXES,,,APAR,,,,,FILESET..... i read in the book.......as i know about RPM in linux.....but in... (2 Replies)
Discussion started by: life008
2 Replies

3. UNIX and Linux Applications

Password management / centralized password management

Hello all, I need help for build server call as Password management / centralized password management server. My situation and example: I have 600 server in my server room running on Linux then I need 1 server only can create login/password and then user can login to all 600 server no... (2 Replies)
Discussion started by: sheikh76
2 Replies

4. What is on Your Mind?

Individual Risk Management (Personal IT Security) and Browser Cache Management

Original post from this thread on browser caching. To add to this, it is an effective security measure to clear absolutely all cached data (cookies, web content, ....) when closing the browser - i.e. in case of a shutdown. It takes a bit of work to re-login to all the sites but websites will not... (7 Replies)
Discussion started by: bakunin
7 Replies
ifc_disable_mgmt_lun(5) 					File Formats Manual					   ifc_disable_mgmt_lun(5)

NAME
ifc_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management luns is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M). Tunable Kernel Parameters ifc_disable_mgmt_lun(5)
All times are GMT -4. The time now is 09:41 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy