Sponsored Content
Full Discussion: EMC Failover
Operating Systems Solaris EMC Failover Post 302366128 by glenioborges on Thursday 29th of October 2009 12:53:48 AM
Old 10-29-2009
EMC Failover

Hi guys,

I'm running vxdmp and powerpath at the same time. Vxdmp for internal disks and powerpath for external.

The problem is that, on the failover tests which a fiber cable should be removed, the system cannot recognize the disks.

Any hints on how to configure powerpath in order to correctly handle the failover?

Thank you
 

10 More Discussions You Might Find Interesting

1. Solaris

Interfaces do not failover

Would anyone know why a V440 Solaris 9 machine's interfaces (ce0 and ce1) will not failover? Both interfaces are on the same subnet, but different IPs. I can pull the plug on once interface (ce0) and ce1 will be accessible. I can reverse it and pull ce1, and ce0 will NOT be accessible. ... (5 Replies)
Discussion started by: StorageGuy
5 Replies

2. HP-UX

is anybody using EMC symmetrix?

Hello, I'm looking for reference sites using HP-UX and EMC symmetrix disk. Then, May I ask you questions? (6 Replies)
Discussion started by: cooldugong
6 Replies

3. Solaris

Emc

Dear gentelmen kindly please update me me how can i know disks on EMC and get size for all disks on EMC? (1 Reply)
Discussion started by: magasem
1 Replies

4. HP-UX

Emc

Dear gentelmen kindly please update me how can i know disks on EMC and get size for all disks on EMC? (0 Replies)
Discussion started by: magasem
0 Replies

5. UNIX for Advanced & Expert Users

AIX MPIO and EMC

We are looking at running MPIO for it's redundancy and load balancing benefits. Does anyone know what pieces of software or modules are needed on the VIO server to get load balancing to work. Remember we are using EMC's DMX3500 storage system. We no longer want to use Powerpath. :rolleyes: ... (2 Replies)
Discussion started by: vxg0wa3
2 Replies

6. UNIX for Advanced & Expert Users

directories failover

Hi, I have 3 directories (/1 /2 and /3) with same contents and want to achieve fail over among them. The Solution i thought of: 1. link /data to /1 (and provide users with /data to access) 2. CRON a script (to run every minute) to verify if /1 exist or not, if it does not exist (or its... (3 Replies)
Discussion started by: prvnrk
3 Replies

7. AIX

failover on 4.5 hacmp

Hi All, How do I trigger the failover on the second hacmp server? Please give me idea and I will do the rest. Thanks, itik (2 Replies)
Discussion started by: itik
2 Replies

8. IP Networking

IP failover needed

All, I am looking to setup a simple IP failover setup, but it seems every place i look has some difficult setup like pacemaker or LVS. I only want to handle the IP piece to failover a VIP. Any suggestions? I checked out keepalived and that my work for me. (4 Replies)
Discussion started by: markdjones82
4 Replies

9. Gentoo

How to failover the cluster ?

How to failover the cluster ? GNU/Linux By which command, My Linux version 2008 x86_64 x86_64 x86_64 GNU/Linux What are the prerequisites we need to take while failover ? if any Regards (3 Replies)
Discussion started by: sidharthmellam
3 Replies

10. AIX

Help with EMC BCV device

I'm trying to auto-mount EMC Symmetrix BCV device at boot. but having problem making BCV available. I put script called mkbcv to the inittab and engineer suggested to add 120 sec sleep between cfgmgr so I did that also. My mkbcv script seems to be working fine, it says "hdisk4 Available" ... (1 Reply)
Discussion started by: shuhei365
1 Replies
if_mpadm(1M)						  System Administration Commands					      if_mpadm(1M)

NAME
if_mpadm - change operational status of interfaces within a multipathing group SYNOPSIS
/usr/sbin/if_mpadm -d interface_name /usr/sbin/if_mpadm -r interface_name DESCRIPTION
Use the if_mpadm utility to change the operational status of interfaces that are part of an IP multipathing group. If the interface is operational, you can use if_mpadm -d to detach or off-line the interface. If the interface is off-lined, use if_mpadm -r to revert it to its original state. When a network interface is off-lined, all network access fails over to a different interface in the IP multipathing group. Any addresses that do not failover are brought down. Network access includes unicast, broadcast, and multicast for IPv4 and unicast and multicast for IPv6. Addresses marked with IFF_NOFAILOVER do not failover. They are marked down. After an interface is off-lined, the system will not use the interface for any outbound or inbound traffic, and the interface can be safely removed from the system without any loss of network access. The if_mpadm utility can be applied only to interfaces that are part of an IP multipathing group. OPTIONS
The if_mpadm utility supports the following options: -d interface_name Detach or off-line the interface specified by interface_name. -r interface_name Reattach or undo the previous detach or off-line operation on the interface specified by interface_name. Unless the -d option was used to detach or off-line the interface, this option will fail. EXAMPLES
Example 1: Detaching an Interface Use the following command to off-line or detach the interface. All network access will failover from hme0 to other interfaces in the same IP multipathing group. If no other interfaces are in the same group, the operation will fail. example% if_mpadm -d hme0 Example 2: Reattaching an Off-line Interface Use the following command to undo the previous operation. Network access will failback to hme0. example% if_mpdadm -r hme0 ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ |Interface Stability |Unstable | +-----------------------------+-----------------------------+ SEE ALSO
ifconfig(1M), in.mpathd(1M), attributes(5) DIAGNOSTICS
off-line failed as there is no other functional interface available in the multipathing group for failing over the network access. This message means that other interfaces in the group are failed over already or the multipathing configuration was not suitable for com- pleting a failover. off-line cannot be undone because multipathing configuration is not consistent across all the interfaces in the group. This message means that some interfaces in the IP multipathing group are not configured consistently with other interfaces in the group, for example, one of the interfaces in the group does not have an IFF_NOFAILOVER address. SunOS 5.10 3 Sep 2002 if_mpadm(1M)