Operating Systems AIX find firmware level through HMC Post 302363144 by ippo on Monday 19th of October 2009 02:45:38 PM
Old 10-19-2009
try this:

Code:
lslic -m <managed system> -t syspower

This User Gave Thanks to ippo For This Post:
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Find run-level in solaris 8.

When the solaris 8 have come up, which command can find out the current run-level? thanks. (2 Replies)
Discussion started by: nianzhe
2 Replies

2. AIX

How can I manage redundant HMC upgrades with firmware upgrades?

Lets says I have 2 HMC's A and B, connected to a p570 managed system. Right now the firmware level of the p570 is EM320_076 and that needs to be upgraded to EM340_095. Now the HMC's are at V7R3.3 and as per the code matrix the HMC's needs to be upgraded to V7R3.4 Servicepack 2. Now my... (5 Replies)
Discussion started by: balaji_prk
5 Replies

3. AIX

How to upgrade AIX Firmware & TL Maintenance Level in AIX

Steps to upgrade AIX TL ( technology Level ) / Maintenance Level in AIX ( including Firmware HMC VIOS ) This article or post covers upgrades for - Hardware Management Console ( HMC ) - Firmware ( also known as microcode ) - VIO ( Virtual I/O Server = PowerVM ) - AIX Version, Technology... (2 Replies)
Discussion started by: filosophizer
2 Replies

4. UNIX for Dummies Questions & Answers

find files on first level folder

Hi: I have: folderA |----folderB |----folder1 |----folder2 |----folder3 |----folder3.1 Question: How can I find *.txt ONLY from /folderA/folderB/ and not the others folder1,2,3?? I tried: find... (8 Replies)
Discussion started by: iga3725
8 Replies

5. Solaris

How to find the Latest Firmware

Dear All I have a Sun Fire v440 server. How to find the latest firmware for this server and from where i can download the firmware. What is theprocedure install the latest firmware. please share the process if possible. How can i check the latest firmware of any sun server. Tahnk u... (1 Reply)
Discussion started by: sudhansu
1 Replies

6. Hardware

I need help to download firmware fo HMC from version 7.3.4 to vervion 7.3.5

All, I need to upgrade my HMC from version 7.3.4 to vervion 7.3.5. The HMC has a Machine type of 7310-CR2 Xseries 335 . Where could I download the firmware for such hardware (HMC Machine type of 7310-CR2 Xseries 335 )? Please answer because I need to upgrade that HMC the HMC to bring to... (3 Replies)
Discussion started by: jesifra
3 Replies

7. AIX

HMC firmware update - "Hard drive" LIC repository ?

Hi, I want to update managed system firmware using HMC. The easiest way to me is to download firmware directly to HMC hard disk. Question: Where shoud I put downloaded firmware in HMC hard disk ? - selection says "Hard disk" - no path no anything. thanks Vilius M. (0 Replies)
Discussion started by: vilius
0 Replies

8. AIX

HMC updates managed system firmware on both T and P sides ?

Hi, I'm planning to update managed system firmware to new release using HMC. This is cite from IBM documentation describing HMC managed system updates: What I know we install new firmware to T side and in case some problems we boot P side and reject new fw on T. So if HMC updates both T and... (0 Replies)
Discussion started by: vilius
0 Replies

9. Solaris

How to find Firmware revision ?

I am having a Sun-Fire-T2000 server which is having Solaris OS running on it. I am not able to find an exact Firmware version. Please suggest something. sc> showhost Host flash versions: OBP 4.30.4 2009/08/19 07:24 Hypervisor 1.7.3.a 2009/10/29 15:50 POST 4.30.4 2009/08/19 07:47... (3 Replies)
Discussion started by: zigi_p5
3 Replies

10. Shell Programming and Scripting

Find and Move Files up One Level

Hi All, So I have another question. I'm trying to search for files with a certain extension and then move all of them up one level in the folder hierarchy. So something like this: original: /path/to/file/test.txt after: /path/to/test.txt I had some great help recently with another... (4 Replies)
Discussion started by: ideal2545
4 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_lpar - Fence agent for IBM LPAR DESCRIPTION
fence_lpar accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_lpar can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -x, --ssh SSH connection (Default Value: 1) -k, --identity-file=<filename> Identity file for ssh -n <id> Name of the partition Partition name -s <id> Name of the managed system Managed system name -H, --hmc-version=<version> Force HMC version to use (3 or 4) (Default Value: 4) -c, --command-prompt=<prompt> Force command prompt (Default Value: [':~>', ']$', '$ ']) -4, --inet4-only Forces agent to use IPv4 addresses only -6, --inet6-only Forces agent to use IPv6 addresses only -u, --ipport=<port> TCP port to use for connection with device -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit -C, --separator=<char> Separator for CSV created by operation list (Default Value: ,) --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 15) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 0) --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password secure SSH connection (Default Value: 1) identity_file Identity file for ssh partition Partition name managed Managed system name hmc_version Force HMC version to use (3 or 4) (Default Value: 4) cmd_prompt Force command prompt (Default Value: [':~>', ']$', '$ ']) inet4_only Forces agent to use IPv4 addresses only inet6_only Forces agent to use IPv6 addresses only ipport TCP port to use for connection with device verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit separator Separator for CSV created by operation list (Default Value: ,) power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 15) power_wait Wait X seconds after issuing ON/OFF (Default Value: 0) delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_lpar (Fence Agent) 2009-10-20 FENCE_AGENT(8)
All times are GMT -4. The time now is 08:00 PM.