10-16-2009
find firmware level through HMC
Is there an HMC command to find the attached managed systems firmware level??
10 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
When the solaris 8 have come up, which command can find out the current run-level?
thanks. (2 Replies)
Discussion started by: nianzhe
2 Replies
2. AIX
Lets says I have 2 HMC's A and B, connected to a p570 managed system.
Right now the firmware level of the p570 is EM320_076 and that needs to be upgraded to EM340_095.
Now the HMC's are at V7R3.3 and as per the code matrix the HMC's needs to be upgraded to V7R3.4 Servicepack 2.
Now my... (5 Replies)
Discussion started by: balaji_prk
5 Replies
3. AIX
Steps to upgrade AIX TL ( technology Level ) / Maintenance Level in AIX ( including Firmware HMC VIOS )
This article or post covers upgrades for
- Hardware Management Console ( HMC )
- Firmware ( also known as microcode )
- VIO ( Virtual I/O Server = PowerVM )
- AIX Version, Technology... (2 Replies)
Discussion started by: filosophizer
2 Replies
4. UNIX for Dummies Questions & Answers
Hi:
I have:
folderA
|----folderB
|----folder1
|----folder2
|----folder3
|----folder3.1
Question:
How can I find *.txt ONLY from /folderA/folderB/ and not the others folder1,2,3??
I tried:
find... (8 Replies)
Discussion started by: iga3725
8 Replies
5. Solaris
Dear All
I have a Sun Fire v440 server. How to find the latest firmware for this server and from where i can download the firmware. What is theprocedure install the latest firmware. please share the process if possible.
How can i check the latest firmware of any sun server.
Tahnk u... (1 Reply)
Discussion started by: sudhansu
1 Replies
6. Hardware
All,
I need to upgrade my HMC from version 7.3.4 to vervion 7.3.5. The HMC has a Machine type of 7310-CR2 Xseries 335 . Where could I download the firmware for such hardware (HMC Machine type of 7310-CR2 Xseries 335 )? Please answer because I need to upgrade that HMC the HMC to bring to... (3 Replies)
Discussion started by: jesifra
3 Replies
7. AIX
Hi,
I want to update managed system firmware using HMC.
The easiest way to me is to download firmware directly to HMC hard disk. Question:
Where shoud I put downloaded firmware in HMC hard disk ? - selection says "Hard disk" - no path no anything.
thanks
Vilius M. (0 Replies)
Discussion started by: vilius
0 Replies
8. AIX
Hi,
I'm planning to update managed system firmware to new release using HMC.
This is cite from IBM documentation describing HMC managed system updates:
What I know we install new firmware to T side and in case some problems we boot P side and reject new fw on T.
So if HMC updates both T and... (0 Replies)
Discussion started by: vilius
0 Replies
9. Solaris
I am having a Sun-Fire-T2000 server which is having Solaris OS running on it.
I am not able to find an exact Firmware version. Please suggest something.
sc> showhost
Host flash versions:
OBP 4.30.4 2009/08/19 07:24
Hypervisor 1.7.3.a 2009/10/29 15:50
POST 4.30.4 2009/08/19 07:47... (3 Replies)
Discussion started by: zigi_p5
3 Replies
10. Shell Programming and Scripting
Hi All,
So I have another question. I'm trying to search for files with a certain extension and then move all of them up one level in the folder hierarchy.
So something like this:
original: /path/to/file/test.txt
after: /path/to/test.txt
I had some great help recently with another... (4 Replies)
Discussion started by: ideal2545
4 Replies
LEARN ABOUT DEBIAN
drobom
DROBOM(8) droboa DROBOM(8)
NAME
drobom - CLI for managing drobo units
SYNOPSIS
drobom [ options ] <command> [ arguments... ]
DESCRIPTION
options is one of:
-c, --command
the command to execute.
-d, --device
the device to operate on (default searches all devices and picks first one found.)
-h, --help
print a usage message
-v, --verbose
verbosity, a bit-field to trigger increased output as needed, mostly for debugging. 1 - General, 2 - Hardware Dialog, 4 - Initia-
tion, 8 - DMP layer, 16- Detection 64 will print everything... (default: 0, as terse as possible.) 128 enables simulation mode (for
testing when no Drobo is available. Dangerous!)
-V, --version
print the version id.
command is one of:
blink identify the drobo by making the lights blink
diag dump diagnostics file into /tmp directory
diagprint <diagdumpfile>
print diagnostics file to standard output
<diagdumpfile> the diagnostic dump file to print.
fwcheck query drobo.com for updates to firmware for the given Drobo
fwload load a specific firmware for the given Drobo. Arguments:
<fwimage> the firmware file to load.
fwupgrade
upgrade the firmware to the latest and greatest, recommended by DRI
help print this text
info <toprint>
print information on a Drobo. The <toprint> argument is a comma separated list of the values below (default is to print all of
them): config, capacity, protocol, settings, slots, firmware, status, options, luns
list show device files for all Drobos found.
name <newname>
Set the name of the Drobo to the given value ( only firmware > 1.3.0 supports this command )
settime sync Drobo's clock to UTC
setlunsize Set the size of LUNS on device. Arguments:
<sz> integer number of TiB to set the lunsize to
<confirmation> Specify 'PleaseEraseMyData' if you really mean it
Note: After execution, Drobo reboots, wait a few minutes before accessing again
shutdown
shutdown drobo (DRI calls this 'standby')
status report how is the Drobo doing
device
raw block device of a drobo (i.e. /dev/sdz) . If not given, assumes all attached drobos.
AUTHOR
This manual page was written by Chris AtLee <chris@atlee.ca> for the Debian project (but may be used by others).
2008 October DROBOM(8)