Sponsored Content
Operating Systems SCO Warning HD: no root disk controller was found Post 302356096 by jgt on Thursday 24th of September 2009 12:58:54 PM
Old 09-24-2009
How many system disks does the POST report, and what condition are they in?
 

10 More Discussions You Might Find Interesting

1. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

2. SCO

warning:hd:no root disk controler was found

hi all i use sco open server reliseas 5 on my system i get an image from system hard disk to another hard disk with acronis software and start system with new(backup)hard disk, but during the boot process some errors generate as follow warning:hd:noroot disk controler was found hd:a boot-time... (2 Replies)
Discussion started by: mehran_malek
2 Replies

3. HP-UX

[Joy Share] - Replace an unknown status controller on HP FC60 disk array

Replace an unknown status controller on HP FC60 disk array Author:JoyOnline JoyChangLu@gmail.com Trouble description: The users detected that the status of controller at A is unknown. Analysis and diagnostic: Physical observed all leds on enclosure of disk array is normal. The... (4 Replies)
Discussion started by: JoyOnLine
4 Replies

4. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

5. Solaris

Help needed to find out the disk controller for veritas disks

hi all i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output # vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online... (2 Replies)
Discussion started by: kingston
2 Replies

6. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

7. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

8. Solaris

Lost Root Password on VXVM Encapsulated Root Disk

Hi All Hope it's okay to post on this sub-forum, couldn't find a better place I've got a 480R running solaris 8 with veritas volume manager managing all filesystems, including an encapsulated root disk (I believe the root disk is encapsulated as one of the root mirror disks has an entry under... (1 Reply)
Discussion started by: sunnyd76
1 Replies

9. Solaris

Disk controller reassignment

Hi The scenario in the oracle t4-1 hardware with solaris 10 is as follows: 1. The initial install on the server was performed with an incorrect disk layout. 2. New disks were ordered and slot into the server. 3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies

10. Solaris

Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1)

Hi, I have a Sun Fire V440 server that fails to boot up correctly. A lot of services are not started and the sytems acts really slow to commands. During boot I can see the following Error: WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1): SCSI transport failed: reason 'reset': retrying... (15 Replies)
Discussion started by: oliwei
15 Replies
vxsplitlines(1M)														  vxsplitlines(1M)

NAME
vxsplitlines - show disks with conflicting configuration copies in a cluster SYNOPSIS
vxsplitlines [-g diskgroup] [-c daname] DESCRIPTION
If you import portions of a disk group on different systems, this can lead to conflicting configuration copies on the disks of the disk group. If the configuration information in a disk group is ambiguous, it may not be possible for Veritas Volume Manager to determine which config- uration copy is most up-to-date. (This is usually termed a serial split brain (SSB) condition when it occurs in a cluster.) You cannot import a disk group in this state unless you specify which disk's configuration copy to use. You can use the vxsplitlines command to see which disks in a disk group have conflicting configuration copies, and use this information together with your knowledge of the history of the disk groups' usage to determine which configuration copy is most valid. The output from vxsplitlines displays the vxdg commands that you can run to import the disk group using the available configuration copies. The -o selectcp option of the vxdg import command is used to select the configuration copy to use for the import. OPTIONS
-c daname Display the SSB IDs for each disk that are stored in the configuration copy on the disk specified by its disk access name. Note: Although the SSB IDs for some disks may match, this does not necessarily mean that those disks' configuration copies have recorded all the configuration changes. When viewed from some other configuration copies, the SSB IDs of the same disks may not match. -g diskgroup Specifies the disk group. If a disk group is not specified, the default disk group is used as determined from the rules on the vxdg(1M) manual page. EXAMPLES
Display the disks on each side of the split in the disk group newdg: vxsplitlines -g newdg Display the SSB IDs stored in the configuration copy on disk c2t4d0: vxsplitlines -g newdg -c c2t4d0 NOTES
The vxsplitlines is primarily intended to be used with private disk groups, but it also works with shared disk groups. The version number of the disk group must be 110 or greater. SEE ALSO
vxdg(1M) Veritas Volume Manager Administrator's Guide VxVM 5.0.31.1 24 Mar 2008 vxsplitlines(1M)