Sponsored Content
Operating Systems AIX IBM SAN Storage DS4700 - Copy Mirror Flashcopy Post 302353373 by funksen on Tuesday 15th of September 2009 08:02:15 AM
Old 09-15-2009
you could set up an lvm mirror, and set the pv state to missing

don't forget to turn the vg quorum off

use chpv

from the man page:
Code:
    r
                   Makes a physical volume unavailable (removed) for logical input and output. If the physical volume is required in order to maintain a volume group quorum, an error occurs and the physical
                   volume remains open.
Examples
       1    To close physical volume hdisk03, enter: chpv -v r hdisk03

            The physical volume is closed to logical input and output until the -v a flag is used.

then zone it to the other lpar, and remove the disk from the vg

that's the way I would do it

Last edited by funksen; 09-15-2009 at 09:11 AM..
 

9 More Discussions You Might Find Interesting

1. AIX

mirror external scsi to san

Hi, How do I mirror an external scsi vg to one hdisk san? The vg has multiple hdisks and the san hdisk has only one. Is this possible or do I need to create the same hdisks as the scsi? What I meant is, if the scsi vg has 10 hdisk then I need to create also 10 hdisk of san with the same... (6 Replies)
Discussion started by: itik
6 Replies

2. AIX

IBM FastT600 SAN - RAID 5 Storage Manager Client v08.33.G5.03 - Recovery?

To summarize the problem: The "IBM FastT Storage Manager Client v8" shows that our Disk Farm is arranged into 6 logical drives each in a RAID 5 configuration. This software also shows that 5 of the 6 logical drives (from Disk Farm) are in a error state: "Failed Logical Drive - Drive Failure".... (1 Reply)
Discussion started by: aix-olympics
1 Replies

3. AIX

MPIO RDAC IBM SAN STORAGE DS4700 ?

Hello, I have AIX 6.1 with TL 4 and it is connected to IBM SAN STORAGE DS4700 After assigning some disks from SAN to AIX, I can see the disks in my AIX as hdisk2 Available 05-00-02 MPIO Other DS4K Array Disk hdisk3 Available 05-00-02 MPIO Other DS4K Array Disk But it should... (0 Replies)
Discussion started by: filosophizer
0 Replies

4. Solaris

Cannot see the IBM SAN storage

HI all, I had recently change the Server storage from EMC to the IBM SAN. but after the configuration, the IBM success to see the server HBA port and successfully assign a LUN for the server. When i go to the server, and restarted it. i use the "format" command to check, but din see any... (1 Reply)
Discussion started by: SmartAntz
1 Replies

5. UNIX for Dummies Questions & Answers

Storage from SAN

hi guys I installed Centos 5.5 (local disk). I am using 2 HBAs Now I mapped 5 LUNs from a Storage. I will be using LVM just to test I assigned a LUN I've read I have to use multipath to avoid my Centos see the LUN twice I enabled mdmpd and multipathd... something else I should do? ... (8 Replies)
Discussion started by: kopper
8 Replies

6. AIX

IBM SAN storage -- cache battery

Hello, I have IBM SAN STORAGE DS4100 and one of the cache battery for the controller is dead. Suddenly the performance has been degraded and access to SAN disks ( reading and writing ) became very slow ? My query: Replacing the battery will take 6 days, so in the mean time what are the ways... (1 Reply)
Discussion started by: filosophizer
1 Replies

7. AIX

IBM SAN STORAGE HOT SPARE DISK

Hello, I have DS4000 IBM SAN Storage ( aka FastT Storage ) One of my disks has failed and I had a hot spare disk covering all the arrays. As the disk failed, immediately the hotspare disk took over the failed disk ( see the JPEG in the attachment ) My Question: How can I make the hotspare... (1 Reply)
Discussion started by: filosophizer
1 Replies

8. AIX

IBM SAN TO SAN Mirroring

Has anyone tried SAN to SAN mirroring on IBM DS SAN Storage. DS5020 mentions Enhanced Remote Mirror to multi-LUN applications I wonder if Oracle High availibility can be setup using Remote Mirror option of SAN ? (1 Reply)
Discussion started by: filosophizer
1 Replies

9. AIX

IBM AIX - SAN Storage DS4300 issue

Hi, This is follow up to the post https://www.unix.com/aix/233361-san-disk-appearing-double-aix.html When I connected Pseries Machine HBA Card ( Dual Port ) directly to the SAN Storage DS4300 , I was able to see Host Port Adapter WWN numbers , although I was getting this message... (2 Replies)
Discussion started by: filosophizer
2 Replies
fp(7d)								      Devices								    fp(7d)

NAME
fp - Sun Fibre Channel port driver DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter port management and other capabilities through well-defined fibre channel adapter driver interfaces. The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri- vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in LIRP and LILP stages of loop initialization. CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties: mpxio-disable Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no" activates I/O multipathing, while mpxio-disable="yes" disables the feature. Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4: name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0 mpxio-disable="yes"; manual_configuration_only Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con- figuration of devices. FILES
/kernel/drv/fp 32-bit ELF kernel driver (x86) /kernel/drv/amd64/fp 64-bit ELF kernel driver (x86) /kernel/drv/sparcv9/fp 64-bit ELF kernel driver (SPARC) /kernel/drv/fp.conf fp driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |mpxio-disable |Unstable | +-----------------------------+-----------------------------+ |manual_configuration_only |Obsolete | +-----------------------------+-----------------------------+ |Availability |SUNWfctl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D) Writing Device Drivers Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994 Fibre Channel Generic Services (FC-GS-2) Project 1134-D Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996 Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996 SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998 Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998 SunOS 5.10 2 Dec 2004 fp(7d)
All times are GMT -4. The time now is 01:35 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy