08-25-2009
Quote:
Originally Posted by
achenle
No one's asked what file system will be going on this RAID array? That can have a large impact on the best stripe size for the array.
FWIW, I'm not aware of any free-as-in-beer Linux file systems that have a block size larger than 4K. Maybe btrfs does, but I don't think that's really ready to use yet, although I'll admit I haven't been following btrfs progress closely.
i will be using ext3 most likelly
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi all
I am working on MSR110 ...Can anyone plz tell me how to use the configuration commands with magnetic reader???. Please help me out as i have to develop API in C on linux platform.MSR110 is not responding to the configuration commands.
Please help...
Regards
Mahima (0 Replies)
Discussion started by: mahima_er
0 Replies
2. UNIX for Advanced & Expert Users
Hi,
Is there are any special preocedure for extending veritas mirror-stripe volume? In my case , volume lay out looks as below
v test - ENABLED ACTIVE 419430400 SELECT - fsgen
pl test-01 test ENABLED ACTIVE 419454720 STRIPE 3/128 RW
sd... (0 Replies)
Discussion started by: 2k7.vipin
0 Replies
3. AIX
Hello all.
I have a volume group with 8 PV's, and a logical volume striped across these 8 volumes.
However, an lslv is showing:
STRIPE WIDTH: 9
STRIPE SIZE: 64k
There's really only eight disks, so how can the stripe width be 9?
ODM also showed this:
# odmget CuAt |... (4 Replies)
Discussion started by: Scott
4 Replies
4. Emergency UNIX and Linux Support
Hi all
I have just had SAN allocate 4*30 GB of disks and had created a new scalable vg and assigned the disks to it:
I used smitty to create vg and the command is: x -y'vgdata1' hdisk82 hdisk83 hdisk84 hdisk85
root@aadcxs08 / : lsvg vgdata1
VOLUME GROUP: vgdata1 VG... (4 Replies)
Discussion started by: hedkandi
4 Replies
5. AIX
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies
6. Solaris
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
Discussion started by: KhawHL
4 Replies
7. Solaris
Hello Admins..
I am going through solaris volume manager guide for RAID-0 concatenation and stripes, I do not understand the concept of stripe from following example of concatenation.
There is an eample for concatenation:
# metainit d25 1 1 c0t1d0s2
d25: Concat/Stripe is setup
the... (5 Replies)
Discussion started by: snchaudhari2
5 Replies
8. Red Hat
Hello,
I want to delete a RAID configuration an old server has.
Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton?
I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
9. Shell Programming and Scripting
Say i have:
g_gateway domain="abc.com" to="123.123.123.123" relay="false"
how do i use awk or sed or any method to get the result below:
abc.com 123.123.123.123 (3 Replies)
Discussion started by: timmywong
3 Replies
LEARN ABOUT HPUX
vxr5check
vxr5check(1M) vxr5check(1M)
NAME
vxr5check - verify RAID-5 volume parity
SYNOPSIS
/etc/vx/bin/vxr5check [-i | -v] [-g diskgroup] volume
DESCRIPTION
The vxr5check utility compares the parity of each stripe of a RAID-5 volume specified by volume. vxr5check reads the data for each stripe,
generates the parity for this stripe, and compares this parity with the existing parity.
vxr5check can be run against the entire RAID-5 volume, or incrementally on RAID-5 stripe boundaries, by specifying the -i option.
OPTIONS
-g diskgroup
Specifies the Veritas Volume Manager (VxVM) disk group name for the RAID-5 volume name for verification. If this option is not
specified, the default disk group is determined using the rules given in the vxdg(1M) manual page.
-i Verifies the RAID-5 volume incrementally per stripes. If a parity mismatch is found, that stripe location is displayed.
-v Verbose output for the incremental vxr5check verification. The verbose option outputs each stripe number that is being verified.
OUTPUT FORMAT
In verbose mode and incremental mode, summary reports for each stripe of the RAID-5 volume are printed in output records. If an error is
returned for a stripe, then an error message and stripe number are displayed. In non-verbose mode, if an error is returned, an error mes-
sage is displayed.
If a parity mismatch error is determined on a stripe, vxr5check exits on that stripe and does not continue for the remaining stripes in the
RAID-5 volume.
FILES
/usr/lib/vxvm/bin/vxr5vrfy The utility that vxr5check calls to perform RAID-5 parity verification operations for the specified RAID-5
volume.
EXIT CODES
The vxr5check utility exits with a non-zero status if the attempted operation fails. A non-zero exit code is not a complete indicator of
the problems encountered, but rather denotes the first condition that prevented further execution of the utility.
See vxintro(1M) for a list of standard exit codes.
NOTES
Do not run vxr5check on a volume that is in degraded mode.
SEE ALSO
vxevac(1M), vxintro(1M), vxmend(1M), vxvol(1M)
VxVM 5.0.31.1 24 Mar 2008 vxr5check(1M)