Currently i got a server which had two interface. I had study the <SystemAdministration Guide: IP> but still donno what is the correct step to configure it. Can u all help me on it? thanks
Code:
# ifconfig -a
lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1
inet 127.0.0.1 netmask ff000000
bge0: flags=201000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4,CoS> mtu 1500 index 2
inet 10.13.15.225 netmask fffff000 broadcast 10.13.15.255
ether 0:14:5e:3d:24:8a
bge1: flags=201000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4,CoS> mtu 1500 index 3
inet 10.13.15.226 netmask fffff000 broadcast 10.13.15.255
ether 0:14:5e:3d:24:8b
Hi All,
I have unplumbed one interface.
after that ifconfig -a shows that
lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1
inet 127.0.0.1 netmask ff000000
e1000g0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2
... (7 Replies)
Probe-based IPMP active - active
Probe-based IPMP active - passive
Link-based only active -standby
????
What are differences between
Probe-based IPMP active - passive anddd
Link-based only active -standby
???!!!
For example in active active probe-based IPMP there are
lets... (6 Replies)
Guide me in setting up IPMP on solaris 10 box .
my system has 2 physical interface
bge0 - not used
bge1 - 10.10.10.10
bge1:1 - 10.10.10.11
please guide , how can i implement IPMP on this server , how many additional test ip is required ? , as 2 ip's are configured on bge1 interface ,... (3 Replies)
Hi,
based on your experience what is the most common IPMP configuration on a two nodes cluster for HA failover / scalable services?
...active-active, active-standby with probe-based failure detection etc.
Thanks (3 Replies)
Hi,
I've a problem when try to detach nic e1000g1.
IPMP configuration:
# ifconfig -a
...cut...
e1000g1: flags=1000842<BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 7
inet 0.0.0.0 netmask 0
ether 0:c:29:67:16:ef
e1000g2: flags=1000842<BROADCAST,RUNNING,MULTICAST,IPv4>... (3 Replies)
Dear All,
I have configured IPMP in one of my SUN machine which is having solros 9 version. I have updated all files like /etc/hosts,/etc/hostname.ce0 and /etc/hostname.ce1 and rebooted the server. But IP's are not mounted which i have given in /etc/hosts file.
Please find the below ifconfig... (6 Replies)
Hi All,
Need your help to explaining why when i configure 2 interface IPMP active-standby appear, INACTIVE and DEPRECATED parameter, detail screen shoot as below :
root@machine01 # ifconfig -a
e1000g0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 7
inet... (6 Replies)
Can any one please explain me the concept behind IPMP in solaris clustering.Basic explanation would be really appreciated...
Thanks in Advance
vks (2 Replies)
Hi,
I have two physical interface connected to solaris box.
1. e1000g1
2. e1000g2
I have added these interfaced under a same IPMP group "IPMP1"
After that I have configured a test address for e1000g1 like below
ifconfig e1000g1 addif <ip-address> netmask + broadcast + -failover... (1 Reply)
Discussion started by: praveensharma21
1 Replies
LEARN ABOUT FREEBSD
if_ntb
NTB(4) BSD Kernel Interfaces Manual NTB(4)NAME
ntb, ntb_hw, if_ntb -- Intel(R) Non-Transparent Bridge driver
SYNOPSIS
To compile this driver into your kernel, place the following lines in your kernel configuration file:
device ntb_hw
device if_ntb
Or, to load the driver as a module at boot, place the following line in loader.conf(5):
if_ntb_load="YES"
DESCRIPTION
The ntb driver provides support for the Non-Transparent Bridge (NTB) in the Intel S1200, Xeon E3 and Xeon E5 processor families.
The NTB allows you to connect two computer systems using a PCI-e link if they have the correct equipment and connectors.
CONFIGURATION
The NTB memory windows need to be configured by the BIOS. If your BIOS allows you to set their size, you should set the size of both memory
windows to 1 MiB. This needs to be done on both systems.
Each system needs to have a different IP address assigned. The MAC address is randomly generated. Also for maximum performance, the MTU
should be set to 16 kiB. This can be done by adding the line below to rc.conf(5):
ifconfig_ntb0="inet 192.168.1.10 netmask 255.255.255.0 mtu 16384"
And on the second system :
ifconfig_ntb0="inet 192.168.1.11 netmask 255.255.255.0 mtu 16384"
If you are using the UDP protocol, you may want to increase the net.inet.udp.maxdgram sysctl(8) variable.
SEE ALSO rc.conf(5), sysctl(8)AUTHORS
The ntb driver was developed by Intel and originally written by Carl Delsey <carl@FreeBSD.org>.
BUGS
If the driver is unloaded, it cannot be reloaded without a system reboot.
The network support is limited. It isn't fully configurable yet. It also isn't integrated into netgraph(4) or bpf(4).
NTB to Root Port mode is not yet supported.
There is no way to protect your system from malicious behavior on the other system once the link is brought up. Anyone with root or kernel
access on the other system can read or write to any location on your system. In other words, only connect two systems that completely trust
each other.
BSD Apr 11, 2013 BSD