Sponsored Content
Operating Systems Solaris I have LUN ID, how to find disk relate to that LUN ID? Post 302338011 by uuontario on Monday 27th of July 2009 12:16:24 AM
Old 07-27-2009
ok, I see. I will give a try tomorrow. Thanks
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

VxVM disk/lun grow

hi, i have a volume on a LUN of an EMC-storage and i need to increase the size. i could increase the size of the LUN on the EMC, i could increase the size of the disk for solaris, but how can i tell the veritas volume manager that the disk is larger now? what i've done: 1. LUN on EMC 2.... (3 Replies)
Discussion started by: pressy
3 Replies

2. Solaris

command to scan Enterprise storage Lun disk in Solaris

I just installed IBMsdd on Solaris diver along with the patches recommended. I also installed 2 - 2Gigs qlogic fiber cards & the corresponding pkges for the cards. What command can I use to scan this LUN disks from my Soalris servers. Solaris doen't seem to be seeing this disks presented on it.... (2 Replies)
Discussion started by: Remi
2 Replies

3. Solaris

LUN not ready

hey guys i got this in my logs what does this mean: (1 Reply)
Discussion started by: sbn
1 Replies

4. AIX

Problem mapping LUN disk from VIOS to the LPAR

Hello guys, It would be so nice of you if someone can provide me with these informations. 1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies

5. Solaris

Find LUN with WWN

Hello all, I need find in my OS (Sun10) on LUN 1Tb with WWN 6005-08b4-0010-7137-0000-e000-0076-0000 (HBA) How do it?, Thanks, (3 Replies)
Discussion started by: aav1307
3 Replies

6. HP-UX

Disk file and Lun Number

HI all, I am confused when I am seeing the output of bdf command ioscan -fnC disk, there is no same files which i have seen in bdf output and ioscan output...One volume was mounted in one folder called /teldb and device file path was /dev/disk/disk48. The same i didnt found in ioscan disk... (6 Replies)
Discussion started by: selvaforum
6 Replies

7. AIX

Not getting Lun Id

Hi, I am not getiting lun id information on VIO Server. I have used the command fget_config command. just showing # prompt. I would like know wheather any other command is there equiv of fget_config which will display lun id? (4 Replies)
Discussion started by: manoj.solaris
4 Replies

8. Solaris

How can i find the LUN ID's

Dear all, i want to get the LUN ID for some disks in solaris 10 what commands options for the MPXIO and inq i want these utilities only because i don't have solution enabler or powerpath BR, (1 Reply)
Discussion started by: maxim42
1 Replies

9. UNIX for Dummies Questions & Answers

Which disk is LUN?

how do I know which hdisk from "lsdev -Cc disk" is my LUN on NetApp after zoning from SAN switch? is it "MPIO other FC SCSI Disk Drive"? (1 Reply)
Discussion started by: malayo
1 Replies

10. HP-UX

HP-UX how formating LUN disk

Hello folks, I have Hp.ux 11.31 and I need know how formating in OS new LUN disk attach to system e.g. the wwid: # scsimgr lun_map -D /dev/rdisk/disk4 LUN PATH INFORMATION FOR LUN : /dev/rdisk/disk4 Total number of LUN paths = 2 World Wide Identifier(WWID) =... (3 Replies)
Discussion started by: aav1307
3 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 03:46 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy