Sponsored Content
Operating Systems Solaris Largest LUN size in Solaris 10 Post 302333618 by pingmeback on Monday 13th of July 2009 02:55:30 PM
Old 07-13-2009
Thanks
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

largest size directory in unix

I want to find the which directory under a directory occupy the maximum size is there is any command to find please help (5 Replies)
Discussion started by: arunkumar_mca
5 Replies

2. Shell Programming and Scripting

file of largest size in pwd

How to find file of the largest size in pwd? (4 Replies)
Discussion started by: rameshparsa
4 Replies

3. Solaris

Solaris 9 or 10 LUN Limitations

Is there a limit to the number of LUNS that can be concatenated using Solaris Volume manager with Soft partitions? I have worked with some AIX admins in the past and there was such a limitation therefore limiting the size the filesystem could grow to. Is there such a limitation in Solaris 9... (6 Replies)
Discussion started by: BG_JrAdmin
6 Replies

4. Solaris

LUN allocation in solaris server

hi all can anyone tell me how to track a new attached LUN in a solaris server?? (3 Replies)
Discussion started by: raynu.sharma
3 Replies

5. Solaris

Set up iscsi LUN on solaris 9?

Hi, I need to set up iscsi LUN on Solaris 9. I've done it on Solaris 10 with iscsiadm. How do you do it on Solaris 9 though? Currently using Solaris 9 update 2. Your help is appreciated. Thanks, Sparcman (6 Replies)
Discussion started by: sparcman
6 Replies

6. Solaris

new attached lun in solaris 10

hi, what are the steps to detect and configure a new attached lun in Solaris 10. Is there any difference between cfgadm and luxadm command ? rgds, snjksh (5 Replies)
Discussion started by: snjksh
5 Replies

7. AIX

Increase LUN size in AIX with VIOS and HACMP

Hello! I have this infraestructure: - 1 POWER7 with single VIOS on Site A. - 1 POWER6 with single VIOS on Site B. - 1 LPAR called NodeA as primary node for PowerHA 6.1 on Site A. - 1 LPAR called NodeB as secondary (cold) node for PowerHA 6.1 on SiteB. - 1 Storage DS4700 on Site A. - 1... (8 Replies)
Discussion started by: enzote
8 Replies

8. Solaris

Problem with Solaris LUN and New FS

Hi All, I'm using Solaris server, SunOS 5.10 Generic_144488-08 sun4u sparc SUNW, SPARC-Enterprise. There is a newly created LUN of 250GB (EMC). I've scanned the system and able to see the new LUN. For example: 103. emcpower19a <DGC-VRAID-0430 cyl 48638 alt 2 hd 256 sec 16>... (4 Replies)
Discussion started by: superHonda123
4 Replies

9. AIX

Uniform LUN size

Hi, Is there any advantage is making all my storage LUNS ( hdisk ) of uniform size. Currently the LUN's are having different size () eg: 50G / 60G / 75G etc ). I am planning for a storage migration....so should i go for uniform lun size or with current LUN size pattern ? Regards, jibu (3 Replies)
Discussion started by: jibujacob
3 Replies

10. Solaris

How to get LUN WWN in Solaris?

How to get LUN WWN (i.e LUN mapped from a storage box say Symmetrix or clariion) in Solaris. fcinfo command does give the Target port wwn but what i'm looking for is the LUN WWN. Any help is appreciated. (2 Replies)
Discussion started by: Manish00712
2 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 04:29 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy