Operating Systems Solaris Sunfire V880 Internal Disk Problem Post 302332008 by frozentin on Tuesday 7th of July 2009 11:59:42 PM
Old 07-08-2009
Your c1t0d0 looks like it is dead, replace it. If I were in your place, I would get c1t2d0 replaced asap.

Can't help you with SVM issues though.
 

10 More Discussions You Might Find Interesting

1. Solaris

X6799A PCI cards and Sunfire v880

Hi, Can X6799A PCI single fiber channel cards be fitted into the top 2 slots of a Sunfire v880. These 2 slots are 66Mhz and X6799A are supposed to be able to connect at this speed. However , I believe the cards are 5volts , whilst the slots are 3.3volts. (2 Replies)
Discussion started by: markdr011
2 Replies

2. Solaris

Serial Port Connection to a Sunfire V880 (having Solaris 10)

Hi, I'mtrying to connect a Device via the serial port to my Solaris 10 environment (Sunfire V880). I have setup ttyb to connect to the Device. I am getting a connected status in my Port Listing (Using a separate Module that I have in the app running in the environment) but the moment I try to... (0 Replies)
Discussion started by: Alchemist
0 Replies

3. Solaris

replacing root disk SunFire 280R

Hi, We had a disk go bad in this SunFire 280R, running Solaris 8 - Generic_117350-46. We replaced the disk and partitioned it. We metadetached all the metadevices but for some reason the new disk is showing up in the metadb as Concat/Stripe and it won't let us re-sync the mirror. We are not... (2 Replies)
Discussion started by: mgb
2 Replies

4. UNIX for Advanced & Expert Users

Forwarding internal internet packets to internal webserver using iptables

Hi, I need to redirect internal internet requests to a auth client site siting on the gateway. Currently users that are authenticated to access the internet have there mac address listed in the FORWARD chain. All other users need to be redirected to a internal site for authentication. Can... (1 Reply)
Discussion started by: mshindo
1 Replies

5. Solaris

sunfire 4100 xbrowser problem

I installed SGD on SUNfire 4100, every thing was working fine, suddenly the machine shutdown due to the power failure. When I again switched it on, it is asking for the login in text mode. No graphics are displaying and even I cannot get its display via xbrowser. While before it was working fine.... (1 Reply)
Discussion started by: bluetooth
1 Replies

6. Filesystems, Disks and Memory

internal disk and external disk question

Hello, We are running sun solaris and it is connected to SAN storage. How do I find what are the disks are internal and what are the disks are connected to SAN? (0 Replies)
Discussion started by: mokkan
0 Replies

7. AIX

Remove internal disk from Veritas Control

I installed new internal disks in my p570. They will be part of a new AIX vg. Unfortunately, we have Veritas Volume Manager running on this AIX 5.2 ml 10 box. Veritas has grabbed control of the disks. I want AIX LVM to control the disks. I cannot get these disks free of Veritas: <lspv... (2 Replies)
Discussion started by: BobSmith
2 Replies

8. Solaris

Attaching 1TB external drive to SunFire v880

Hi I have a 1TB external drive that I want to attach to a SunFire v880 server which runs on Solaris 9. After attaching the external drive what commands should I issue so that the drive will be seen by the server? (7 Replies)
Discussion started by: rahmantanko
7 Replies

9. Red Hat

Disk in Linux machine are internal or external

How to check whether the disk in linux machine are internal or external ( from nas or san). How to identify internal(local) and external disks. Following are some details of my server. Thanks. #df -h Filesystem Size Used Avail Use% Mounted on /dev/sda3 15G 3.5G 10G... (2 Replies)
Discussion started by: salmanraza
2 Replies

10. Hardware

Sunfire V880

Hi Does someone have the latest firmware for a sunfire v880 I have a problem with the FC-AL disk i guess i need to upgrade the firmware but i dont have a support with oracle and i can't find it anywhere thank you (4 Replies)
Discussion started by: simplextibi
4 Replies
scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
All times are GMT -4. The time now is 06:46 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy