Sponsored Content
Full Discussion: A1000 Disk storage array
Operating Systems Solaris A1000 Disk storage array Post 302329712 by DukeNuke2 on Monday 29th of June 2009 09:07:50 AM
Old 06-29-2009
the a1000 is a hardware raid. you can't the the disks, only luns mapped from the box. if you need more luns, you'll need to download "raid manager 6.xx" software from suns webpage. the software is needed to configure the a1000 array.
 

6 More Discussions You Might Find Interesting

1. Solaris

Managing disk array on A1000

I would want to ask on what software do i need to configure disk array for StorEdge A1000. (Sun Enterprise 450 - currently installed with SUN Solaris 9.) Is it using RAID Manager 6.22? And is it compatible with SUN Solaris 9 or 10? Thanks in advance for reading or replying my post. (2 Replies)
Discussion started by: beginningDBA
2 Replies

2. Solaris

Disk Storage Need to Add more Disk

Hi, Anyone can help me, just want to confirm, if possible adding a disk storage that we have a RAWDATA with +ASM in our database. If possible, what would you recommend "workaround used" from us to do and the preparation. And also how long the downtime will take. Our disk continuous to grow,... (0 Replies)
Discussion started by: fpalero
0 Replies

3. HP-UX

HP Storage Array

hi I need to check status and configure HP Storage Array device. HP Storageworks P2000 Please suggest (0 Replies)
Discussion started by: anand87
0 Replies

4. Solaris

Storage Array not readable

Hi We have an array connected to the machine but when i issue format command i dont see it. But the array is up and running and there are no warning lights. Is there a way to find that array from the OK boot prompt? Please advise. Thanks (9 Replies)
Discussion started by: prash358
9 Replies

5. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

6. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
SG_LUNS(8)							     SG3_UTILS								SG_LUNS(8)

NAME
sg_luns - send the SCSI REPORT LUNS command SYNOPSIS
sg_luns [--decode] [--help] [--hex] [--maxlen=LEN] [--quiet] [--raw] [--select=SR] [--verbose] [--version] DEVICE DESCRIPTION
Send the SCSI REPORT LUNS command to the DEVICE and outputs the response. In the SPC-3 SCSI standard support for this command is mandatory. OPTIONS
Arguments to long options are mandatory for short options as well. -d, --decode decode logical unit numbers into their hierarchical parts. Interprets luns as described in SAM-3 when the HiSup bit is set in a standard INQUIRY's response. -h, --help output the usage message then exit. -H, --hex output response to this command in ASCII hex. -m, --maxlen=LEN where LEN is the (maximum) response length in bytes. It is placed in the cdb's "allocation length" field. If not given (or LEN is zero) then 8192 is used. The maximum allowed value of LEN is 65536. -q, --quiet output ASCII hex rendering of each report lun, one per line. -r, --raw output response in binary (to stdout). -s, --select=SR this option sets the 'select report' field (SR) in the SCSI REPORT LUNS command. The default value is 0. When 0 is given (or this option is not specified) then the DEVICE should yield a list of luns addressable via this "I_T nexus" that use the following lun addressing methods: logical unit addressing, peripheral device addressing and flat space addressing. When 1 is given the DEVICE should yield a list of only "well known" logical units addressable via this "I_T" nexus. When 2 is given the DEVICE should yield all luns addressable via this "I_T" nexus. To simplify, for the I_T nexus associated with the DEVICE, the meanings of the SR values are: 0 : all luns excluding well known logical units 1 : well known logical units 2 : all luns Values between 0xf8 and 0xff (inclusive) are vendor specific (SPC-4 (rev 32), other values greater than 2 are reserved. -v, --verbose increase the level of verbosity, (i.e. debug output). -V, --version print the version string and then exit. EXIT STATUS
The exit status of sg_luns is 0 when it is successful. Otherwise see the sg3_utils(8) man page. AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2004-2011 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
sg_inq(8) sg3_utils-1.33 August 2011 SG_LUNS(8)