I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why?
What should I do in order to see 12 disks?
Thanks in advance.
Last edited by DukeNuke2; 06-29-2009 at 10:08 AM..
Reason: added code tags
I would want to ask on what software do i need to configure disk array for StorEdge A1000. (Sun Enterprise 450 - currently installed with SUN Solaris 9.)
Is it using RAID Manager 6.22? And is it compatible with SUN Solaris 9 or 10?
Thanks in advance for reading or replying my post. (2 Replies)
Hi,
Anyone can help me, just want to confirm, if possible adding a disk storage that we have a RAWDATA with +ASM in our database. If possible, what would you recommend "workaround used" from us to do and the preparation. And also how long the downtime will take.
Our disk continuous to grow,... (0 Replies)
Hi
We have an array connected to the machine but when i issue format command i dont see it. But the array is up and running and there are no warning lights.
Is there a way to find that array from the OK boot prompt?
Please advise.
Thanks (9 Replies)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
LEARN ABOUT HPUX
vxpfto
vxpfto(1M)vxpfto(1M)NAME
vxpfto - set Powerfail Timeout (pfto)
SYNOPSIS
vxpfto -g diskgroup -t timeout
vxpfto [-g diskgroup] -t timeout volume_list
vxpfto [-g diskgroup] -o pftostate={enabled|disabled}
vxpfto [-g diskgroup] -o pftostate={enabled|disabled} volume_list
DESCRIPTION
Powerfail Timeout is an attribute of a SCSI disk connected to an HP-UX host (see the pfto(7) man page). The vxpfto command sets the Power-
fail Timeout interval on a set of Volume Manager disks, either all disks in a disk group, or all disks underlying the volumes listed.
The first form of the command sets the same PFTO value for all the disks in the specified VxVM diskgroup.
In the second form, all disks underlying the given list of volumes are selected, optionally restricted by the disk group specified with the
-g option. If you specify a diskgroup, any volume in the list not belonging to the diskgroup is ignored.
Use the -o pftostate option to disable or enable PFTO. By default, PFTO is enabled. You can enable PFTO either on all disks in a disk
group, or on all disks underlying the volumes listed.
If you invoke vxpfto without arguments, it displays a usage message.
OPTIONS -g diskgroup
Specifies the disk group for the operation, either by disk group ID or by disk group name.
-o pftostate={enabled|disabled}
Enables or disables the use of PFTO for IO.
-t timeout
Specifies the PFTO value in seconds. The value must be zero or a positive integer. Zero represents the system default PFTO
value. The default value depends on the disk driver controlling the disk device.
volume_list
A list of VxVM volume names. List items must be separated by white-space.
EXIT CODES
vxpfto returns a zero if successful. If it encounters an error, vxpfto exits and displays a message on standard error. Defined exit codes
are:
0 Success.
1 No PFTO value specified.
2 No diskgroup or volume list specified.
3 Illegal PFTO value specified.
EXAMPLES
Set the PFTO value on all disks in disk group testdg to 100 seconds:
vxpfto -t 100 -g testdg
Set the PFTO value to 50 seconds on all disks underlying volume01 and volume02 in disk group testdg:
vxpfto -t 50 -g testdg volume01 volume02
Set the PFTO value to 300 seconds on all disks underlying volume01 and volume02, even though they are not in the same disk group:
vxpfto -t 300 volume01 volume02
Disable PFTO on all disks in disk group testdg:
vxpfto -g testdg -o pftostate=disabled
Enable PFTO on all disks underlying volume01 and volume02i in disk group testdg:
vxpfto -g testdg -o pftostate=enabled volume01 volume02
SEE ALSO vxdisk(1M), pfto(7)VxVM 5.0.31.1 24 Mar 2008 vxpfto(1M)