A1000 Disk storage array

I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why?
What should I do in order to see 12 disks?

Thanks in advance.

Code:
# format
Searching for disks...done

AVAILABLE DISK SELECTIONS:
       0. c0t0d0 <DEFAULT cyl 19781 alt 2 hd 16 sec 63>
          /pci@1f,0/ide@d/dad@0,0
       1. c0t2d0 <DEFAULT cyl 38307 alt 2 hd 16 sec 255>
          /pci@1f,0/ide@d/dad@2,0
       2. c1t5d0 <Symbios-StorEDGEA1000-0205 cyl 25789 alt 2 hd 64 sec 64>
          /pci@1f,0/pci@5/scsi@1/sd@5,0


Last edited by DukeNuke2; 06-29-2009 at 10:08 AM.. Reason: added code tags
 

6 More Discussions You Might Find Interesting

1. Solaris

Managing disk array on A1000

I would want to ask on what software do i need to configure disk array for StorEdge A1000. (Sun Enterprise 450 - currently installed with SUN Solaris 9.) Is it using RAID Manager 6.22? And is it compatible with SUN Solaris 9 or 10? Thanks in advance for reading or replying my post. (2 Replies)
Discussion started by: beginningDBA
2 Replies

2. Solaris

Disk Storage Need to Add more Disk

Hi, Anyone can help me, just want to confirm, if possible adding a disk storage that we have a RAWDATA with +ASM in our database. If possible, what would you recommend "workaround used" from us to do and the preparation. And also how long the downtime will take. Our disk continuous to grow,... (0 Replies)
Discussion started by: fpalero
0 Replies

3. HP-UX

HP Storage Array

hi I need to check status and configure HP Storage Array device. HP Storageworks P2000 Please suggest (0 Replies)
Discussion started by: anand87
0 Replies

4. Solaris

Storage Array not readable

Hi We have an array connected to the machine but when i issue format command i dont see it. But the array is up and running and there are no warning lights. Is there a way to find that array from the OK boot prompt? Please advise. Thanks (9 Replies)
Discussion started by: prash358
9 Replies

5. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

6. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 04:33 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy