06-28-2009
Thanks for the help. As both of you suggested, A5200 will be the better option. I will still have to hunt down for the hardware in running condition and also the fibre card.
As I was looking around after the post, I have also found out another hardware raid Sun T3 array and the seller mentioned they required a new battery. Have you guys every had a chance to work with that model and also had any ideas on pros and cons with a5200/a1000?
Cheers and thank you again.
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi,
I am a Dba and very new to filesystems and stuff.
I think that we have Veritas filesystems on my Sun SOlaris 5.8 box, how do I confirm this: all my filesystems are mounted like this:
/dev/vx/dsk...
Now we are also using disk arrays (storedge a1000) how do I access them from the system.... (1 Reply)
Discussion started by: knarayan
1 Replies
2. UNIX for Advanced & Expert Users
Hi,
I'm facing problem in connecting a Raid A1000 to E250 and E450. ( Both machines with Solaris 2.6 OS and patched, with different
scsi-initiator-ids - 7 & 3 ).
BTW, I'm not using this setup to access raid data from both machines simultaneously. There is Veritas Cluster Server monitoring... (1 Reply)
Discussion started by: shibz
1 Replies
3. UNIX for Dummies Questions & Answers
After searching and finding the link to the A1000 pdf ( http://192.18.99.138/805-7147/805-7147.pdf ) my questions are:
1) I have a battery failure on a A1000. I know that caching is disabled and it reports to see log. After reading the manual I have learned that the battery is a data-cache... (2 Replies)
Discussion started by: finster
2 Replies
4. Solaris
Sorry if this seems trivial. i have been given a task at work to configure a sun processing server "enterprise 4500" so it can work with the a storage server "storedge A5200" and "storedge D1000"
the truth is i have never worked on a sun server before. i need a guideline (step by step) as to... (5 Replies)
Discussion started by: lawalidowu
5 Replies
5. Solaris
I have a SUN Blade 1000 running Solaris 10 and an A1000 array.
I know that this combo is not supported by SUN but will it work?
The raid manager software is installed and it says that the firmware needs to be upgraded -it is at I think level 2.05 something.
I can see all the disks in a... (13 Replies)
Discussion started by: tribbles
13 Replies
6. Solaris
Hello Experts,
I am using E250 on that solais 10 5/08 installed. I am unable to see disks. I connected 2 disks in that storage of 18gb each. When I run format command it is showing that 2 disks one is operating system and another one is 6MB. I checked probe-scsi and probe-scsi-all at ok... (6 Replies)
Discussion started by: younus_syed
6 Replies
7. Solaris
I am new to the unix world. I have SunBlade 100 and A1000 Disk storage array with 12 Hard drives. I used SCSI card and SCSI cables to connect. When I do the format command,I can see disk storage as one disk instead of 12 disks as below. Could anybody can explain why?
What should I do in order... (1 Reply)
Discussion started by: Dulasi
1 Replies
8. Solaris
hi friends how we can create luns in A1OOO storage ..plzhelp its very urgent
when ever i am connect to A1000 raid controller through laptop with console cable with the help of hyperterminal..i isued serial port parameters which i mentioned below..
Set serial port parameters to:
�... (1 Reply)
Discussion started by: tv.praveenkumar
1 Replies
9. Solaris
I would want to ask on what software do i need to configure disk array for StorEdge A1000. (Sun Enterprise 450 - currently installed with SUN Solaris 9.)
Is it using RAID Manager 6.22? And is it compatible with SUN Solaris 9 or 10?
Thanks in advance for reading or replying my post. (2 Replies)
Discussion started by: beginningDBA
2 Replies
LEARN ABOUT MINIX
bestups
BESTUPS(8) NUT Manual BESTUPS(8)
NAME
bestups - Driver for Best Power / SOLA (Phoenixtec protocol) UPS equipment
NOTE
This man page only documents the hardware-specific features of the bestups driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
bestups was designed to monitor Best Power UPS hardware like the Fortress, Fortress Telecom, Axxium Rackmount and Patriot Pro. It also
recognizes and supports SOLA units such as the 325, 520 and 620. In addition, the Best 610 is supported using the 'ID' option.
Other UPS hardware using the Phoenixtec protocol should also work, but they will generate a warning since their battery information is not
known.
This driver does not support some older Best/SOLA units.
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5):
nombattvolt=num
Override the battery float voltage which is normally determined by asking the hardware. This is useful if your UPS constantly reports
battery.charge values just below 100% even when it's completely charged.
If you have this problem, set this to whatever battery.voltage reports when the UPS is known to be completely charged with a good
battery.
The author's Best Fortress 750 uses nombattvolt=27.4.
battvoltmult=num
Multiply the reported battery voltage by this number. Some devices report only a fraction of the total battery voltage.
For example, the SOLA 610 700VA UPS (with a 24V battery) reports the single cell voltage (about 2.27V when fully charged). In this
particular case you can set battvoltmult = 12 in ups.conf(8) to fix this.
ID=string
Set the Identification response string. This should only be used with hardware that supports the Phoenixtec protocol status inquiry
commands, but not the "ID" command, such as the Best/SOLA 610. Format of the ID string is: AAA,BBBB,CCC,DDD,EE.E,FF.F
AAA is the three-character identification for the UPS model.
BBBB is the output power in VA (volt amperes). B is an integer number ranging from 0 to 9.
CCC is the Nominal Input Voltage. C is an integer number ranging from 0 to 9. The unit is Volts AC.
DDD is the Nominal Output Voltage. D is an integer number ranging from 0 to 9. The unit is Volts AC.
EE.E is the Battery Voltage that will cause the UPS to shut itself off. E is an integer number ranging from 0 to 9. Then unit is Volts
DC and a decimal point is present.
FF.F or FFF.F is the Battery Voltage at full charge. F is an integer number ranging from 0 to 9. Then unit is Volts DC. Typically, for
700VA, 1KVA and 1.5KVA units, the format is FF.F. For 2KVA and 3KVA units, the format is FFF.F.
Example: a Best 610 1.5KVA unit would use the string "610,1500,120,120,10.0,48.0".
BUGS
The battery charge percentage value (in battery.charge) is derived from the voltage data that the UPS returns, since the UPS doesn't return
that value directly. On some hardware, the charge will remain at 100% for a long time and then drops quickly shortly before the battery
runs out. You can confirm from the battery.voltage readings that this is a problem with the UPS and not this driver.
Similarly, the float from the charger in some models forces the battery charge percentage back up to 100% immedately after the UPS goes
back on-line, so you can't tell when it is really recharged.
Finally, some models give one value for the battery's nominal voltage and yet actually have a nominal voltage slightly below that. This
leads to things such as the perpetual 98.7% charge on the author's Fortress 750, even when it's been charging for weeks. You can use
nombattvolt= in ups.conf(8) to fix this.
AUTHOR
Russell Kroll, Jason White
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/