Hi all
I plan to install Solaris 10U6 on some SPARC server using ZFS as root pool, whereas I would like to keep the current setup done by VxVM:
- 2 internal disks: c0t0d0 and c0t1d0
- bootable root-volume (mirrored, both disks)
- 1 non-mirrored swap slice
- 1 non-mirrored slices for Live... (1 Reply)
I created a pool the other day. I created a 10 gig files just for a test, then deleted it.
I proceeded to create a few files systems. But for some reason the pool shows 10% full, but the files systems are both at 1%? Both files systems share the same pool.
When I ls -al the pool I just... (6 Replies)
I need to migrate an existing raidz pool to a new raidz pool with larger disks. I need the mount points and attributes to migrate as well. What is the best procedure to accomplish this. The current pool is 6x36GB disks 202GB capacity and I am migrating to 5x 72GB disks 340GB capacity. (2 Replies)
Other than export/import, is there a cleaner way to rename a pool without unmounting de FS?
Something like, say "zpool rename a b"?
Thanks. (2 Replies)
installed Solaris 11 Express on my server machine a while ago. I created a Z2 RAID over five HDDs and created a few ZFS filesystems on it.
Once I (unintentionally) managed to fill the pool completely with data and (to my surprise) the filesystems stopped working - I could not read/delete any... (3 Replies)
I am trying to test simple zfs functionality on a FreeBSD 8.2 VM. When I try to run a 'zpool create' I receive the following error:
# zpool create zfspool /dev/da0s1a
cannot create 'zfspool': no such pool or dataset
# zpool create zfspool /dev/da0
cannot create 'zfspool': no such pool or... (3 Replies)
I accidently added a disk in different zpool instead of pool, where I want.
root@prtdrd21:/# zpool status cvfdb2_app_pool
pool: cvfdb2_app_pool
state: ONLINE
scan: none requested
config:
NAME STATE READ WRITE CKSUM
cvfdb2_app_pool ONLINE 0 0 0... (1 Reply)
I have a newly created zpool, and I have set compression on, for the whole pool:
# zfs set compression=on newPool
Now I have zfs send | zfs receive lot of snapshots to my newPool, but the compression is gone. I was hoping that I would be able to send snapshots to the new pool (which is... (0 Replies)
On an OmniOS server, I removed a single-disk pool I was using for testing.
Now, when I run zpool import it will show it as FAULTED, since that single disk not available anymore.
# zpool import
pool: fido
id: 7452075738474086658
state: FAULTED
status: The pool was last... (11 Replies)
Discussion started by: priyadarshan
11 Replies
LEARN ABOUT OSF1
sys_attrs_pci
sys_attrs_pci(5) File Formats Manual sys_attrs_pci(5)NAME
sys_attrs_pci - pci subsystem attributes
DESCRIPTION
This reference page lists and describes attributes for the PCI (pci) kernel subsystem. Refer to the sys_attrs(5) reference page for an
introduction to the topic of kernel subsystem attributes.
For this subsytem, users should modify only the following attribute and do so only for the purpose described. Any other visible attributes
cannot or should not be modified.
A bit-mask setting that allows the developer of PCI hardware and softwareto determine the PCI configuration parameters on an Alpha
system based on the PCI bus. By setting PCI_Developer_Debug to different values, a variety of hardware-related or software-related
information about all PCI devices on an AlphaServer are printed out at system bootstrap time. If loadable drivers are used, loadable
configuration data is also printed out on execution of the sysconfig -c command.
Refer to the /usr/include/io/dec/pci/pci_debug.h file for valid bit-field settings for this attribute. The pci_debug.h file con-
tains macro definitions that state the type of information that is printed out if PCI_Developer_Debug is set to a particular value.
Any combination of the bit-flags is valid. For example, the value 0x70 allows the hardware or software developer to see the PCI
configuration header information that the kernel reads or assigns to PCI devices.
Default value: 0
Minimum value: 0
Maximum value: FFFFFFFF(16)SEE ALSO sys_attrs(5)
Writing PCI Bus Device Drivers
sys_attrs_pci(5)