Sponsored Content
Operating Systems Solaris Shared Storage Array is DEGRADED Post 302326706 by amitranjansahu on Thursday 18th of June 2009 01:10:37 PM
Old 06-18-2009
as far i know you can re register the after you plugged in the cable of your SAN device. it might be a bug that the os does not register automatic. i suggest you to check for the lattest solaris patch and bugs for update.you can manually re register via gui.
 

5 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Storage array question

We just purchased a MOD30 disk array strage system. We have 15 drives and 2 hot spares. We're running a database app with 8 data sets. I'm trying to get the best i/o speed out of my disk configuration. Right now I have 3 raid5 arrays setup. This seems to offer the same performance as having the... (1 Reply)
Discussion started by: ncmurf00
1 Replies

2. Solaris

storage array simulator

hi i haven't much experience in solaris. I would like to know about storage. how to configure,how it is working etc....can i get any simulator for doing these work? plaese send me the link . please help me advance thanks to all (2 Replies)
Discussion started by: sijocg
2 Replies

3. HP-UX

HP Storage Array

hi I need to check status and configure HP Storage Array device. HP Storageworks P2000 Please suggest (0 Replies)
Discussion started by: anand87
0 Replies

4. Solaris

Storage Array not readable

Hi We have an array connected to the machine but when i issue format command i dont see it. But the array is up and running and there are no warning lights. Is there a way to find that array from the OK boot prompt? Please advise. Thanks (9 Replies)
Discussion started by: prash358
9 Replies

5. Solaris

Strange isuse with shared storage in Solaris 10

i have luns offered by SE3310 being mounted on two T2000 servers (sun solaris 10u11) . i can see the files on both servers but if i create a new file or rename n existing file on one node its not immediately visible on the other unless i unmount n remount the partition ..how can i fix this ? (2 Replies)
Discussion started by: aliyesami
2 Replies
IDA(4)							   BSD Kernel Interfaces Manual 						    IDA(4)

NAME
ida -- Compaq Intelligent Drive Array Controllers SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device scbus device ida Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): ida_load="YES" DESCRIPTION
The Compaq Intelligent Drive Array (IDA) technology is used to distribute data across an array of hard drives. It unites these hard drives into one or more high-performance logical drives. The drive array is managed by an array controller. These controllers have the ability to provide fault tolerance for the connected drives and optionally provide write cache for the logical drives. It is also possible for an application to access the SCSI bus subsystem directly by using the pass-through interface. HARDWARE
The following controllers are supported by the ida driver: o Compaq SMART Array 221 o Compaq Integrated SMART Array Controller o Compaq SMART Array 4200 o Compaq SMART Array 4250ES o Compaq SMART 3200 Controller o Compaq SMART 3100ES Controller o Compaq SMART-2/DH Controller o Compaq SMART-2/SL Controller o Compaq SMART-2/P Controller o Compaq SMART-2/E Controller o Compaq SMART Controller IMPLEMENTATION NOTES
Extreme caution should be exercised when using the pass-through interface. It is possible to interfere with normal system I/O and cause hangs if pass-through is used to an active device. Pass-through should only be used to a device that is otherwise quiescent. SEE ALSO
cam(4), pass(4), xpt(4), camcontrol(8) AUTHORS
The ida driver was written by Jonathan Lemon <jlemon@FreeBSD.org> and Matthew N. Dodd <mdodd@FreeBSD.org>. This manual page was written by Tom Rhodes <trhodes@FreeBSD.org>. BSD