06-18-2009
as far i know you can re register the after you plugged in the cable of your SAN device. it might be a bug that the os does not register automatic. i suggest you to check for the lattest solaris patch and bugs for update.you can manually re register via gui.
5 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
We just purchased a MOD30 disk array strage system.
We have 15 drives and 2 hot spares.
We're running a database app with 8 data sets.
I'm trying to get the best i/o speed out of my disk configuration.
Right now I have 3 raid5 arrays setup. This seems to offer the same performance as having the... (1 Reply)
Discussion started by: ncmurf00
1 Replies
2. Solaris
hi
i haven't much experience in solaris. I would like to know about storage. how to configure,how it is working etc....can i get any simulator for doing these work? plaese send me the link .
please help me
advance thanks to all (2 Replies)
Discussion started by: sijocg
2 Replies
3. HP-UX
hi
I need to check status and configure HP Storage Array device.
HP Storageworks P2000
Please suggest (0 Replies)
Discussion started by: anand87
0 Replies
4. Solaris
Hi
We have an array connected to the machine but when i issue format command i dont see it. But the array is up and running and there are no warning lights.
Is there a way to find that array from the OK boot prompt?
Please advise.
Thanks (9 Replies)
Discussion started by: prash358
9 Replies
5. Solaris
i have luns offered by SE3310 being mounted on two T2000 servers (sun solaris 10u11) . i can see the files on both servers but if i create a new file or rename n existing file on one node its not immediately visible on the other unless i unmount n remount the partition ..how can i fix this ? (2 Replies)
Discussion started by: aliyesami
2 Replies
IDA(4) BSD Kernel Interfaces Manual IDA(4)
NAME
ida -- Compaq Intelligent Drive Array Controllers
SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file:
device scbus
device ida
Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5):
ida_load="YES"
DESCRIPTION
The Compaq Intelligent Drive Array (IDA) technology is used to distribute data across an array of hard drives. It unites these hard drives
into one or more high-performance logical drives. The drive array is managed by an array controller.
These controllers have the ability to provide fault tolerance for the connected drives and optionally provide write cache for the logical
drives. It is also possible for an application to access the SCSI bus subsystem directly by using the pass-through interface.
HARDWARE
The following controllers are supported by the ida driver:
o Compaq SMART Array 221
o Compaq Integrated SMART Array Controller
o Compaq SMART Array 4200
o Compaq SMART Array 4250ES
o Compaq SMART 3200 Controller
o Compaq SMART 3100ES Controller
o Compaq SMART-2/DH Controller
o Compaq SMART-2/SL Controller
o Compaq SMART-2/P Controller
o Compaq SMART-2/E Controller
o Compaq SMART Controller
IMPLEMENTATION NOTES
Extreme caution should be exercised when using the pass-through interface. It is possible to interfere with normal system I/O and cause
hangs if pass-through is used to an active device. Pass-through should only be used to a device that is otherwise quiescent.
SEE ALSO
cam(4), pass(4), xpt(4), camcontrol(8)
AUTHORS
The ida driver was written by Jonathan Lemon <jlemon@FreeBSD.org> and Matthew N. Dodd <mdodd@FreeBSD.org>. This manual page was written by
Tom Rhodes <trhodes@FreeBSD.org>.