Sponsored Content
Full Discussion: POWER6 VIO Failover
Operating Systems AIX POWER6 VIO Failover Post 302319486 by filosophizer on Monday 25th of May 2009 10:49:02 AM
Old 05-25-2009
thanks for the quick answer.

1) yes LUNS are mapped to VTDs

2) Client Partitions are OFF

3) use rmdev -dev vtdname -ucfg
will this have any adverse affect on the data / san path / application ?

4) installed MPIO and SDDPCM drivers and rebooted VIO two times but no luck.. same problem occurs.

uninstalled MPIO and SDDPCM

rebooted

installed

rebooted

still same problem....
 

9 More Discussions You Might Find Interesting

1. AIX

Oracle 10G best practices on Power6 AIX5.3

Can anyone point me to any best practices for partitioning, resource prerequisites, and implementation of Oracle 10G release 2 with RAC on 2 power6 550's running AIX5.3 as a cluster? (1 Reply)
Discussion started by: JodyTek
1 Replies

2. AIX

Power6 Virtual Fibre Channel Adapter

Hello, Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter. It is similar to virtual scsi adapter. In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies

3. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

4. AIX

AIX 6.1 Power6 - Sys CPU utilization twice that of User

Hello, We just purchased two new 4-way (one active one failover) 5Ghz Power6 Servers (failover) with 64GB RAM (32GB per node) runing AIX 6.1 with two LPARs per node connected to our SAN with two 4GB HBAs. The PROD LPAR has 2 dedicated CPUs (4 virtual) and the TEST LPAR has 2 dedicated CPUs. ... (3 Replies)
Discussion started by: troym72
3 Replies

5. AIX

HACMP with VIO, service IP failover

Would anyone please kindly help to solve this problem... An LPAR with the below network configuration. ent0 and ent1 are logical lan (virtual ethernet) from VIO SEA. en0 1.2.3.4 <- boot ip 192.168.1.1 <- persistent ip 192.168.1.10 <- service ip en1 11.22.33.44 <- boot ip When I... (6 Replies)
Discussion started by: skeyeung
6 Replies

6. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

7. AIX

Power6 vs. Power7 hardware performance

I know I will get blasted for posting here, not know where to post this, however, I have performance question between the 2 platforms. Not knowing the exact processors in each box, but the Power6 Platform clock speed is 4400 (?? at least what was told to me), and the Power7 clock speed is 3500.... (5 Replies)
Discussion started by: mrmurdock
5 Replies

8. AIX

How to get power6 power FRU?

how to get power6 power FRU? the power5 can get by this command: lscfg -vp | grep -p 'AC PS' | grep FRU however, the power6 machine cannot get any info for that command. thanks (1 Reply)
Discussion started by: rainbow_bean
1 Replies

9. AIX

Hard drive compatibility for POWER6 p520

Hi, I have recently inherited an old p520 from work running AIX 6.1, based on the POWER6 CPU. I'm planning to play around with it and use it to learn the system, so this is a purely personal project. The machine is not under a support contract any more. I am looking to replace one of the disks... (11 Replies)
Discussion started by: topcat
11 Replies
rem_drv(1M)                                                                                                                            rem_drv(1M)

NAME
rem_drv - remove a device driver from the system SYNOPSIS
rem_drv [-b basedir] device_driver The rem_drv command informs the system that the device driver device_driver is no longer valid. If possible, rem_drv unloads device_driver from memory. rem_drv also updates the system driver configuration files. If rem_drv has been executed, the next time the system is rebooted it automatically performs a reconfiguration boot (see kernel(1M)). The following options are supported: -b basedir Sets the path to the root directory of the diskless client. Used on the server to execute rem_drv for a client. The client machine must be rebooted to unload the driver. Note - The root file system of any non-global zones must not be referenced with the -b option. Doing so might damage the global zone's file system, might compromise the security of the global zone, and might damage the non-global zone's file system. See zones(5). Example 1: Removing the sd Driver The following example removes the sd driver from use: example% rem_drv sd Example 2: Removing a Diskless Client The following example removes the driver from the sun1 diskless client. The driver is not uninstalled or unloaded until the client machine is rebooted. example% rem_drv -b /export/root/sun1 sd Note the caveat on the use of the -b option in the description of that option, above. See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ add_drv(1M), kernel(1M), update_drv(1M), attributes(5), devfs(7FS) 6 Apr 2005 rem_drv(1M)