Sponsored Content
Top Forums Shell Programming and Scripting sh with Oracle utilities fails Post 302311860 by simonsimon on Wednesday 29th of April 2009 09:08:51 PM
Old 04-29-2009
Question sh with Oracle utilities fails

I log into HPUX as oracle user.

I use sh shell.

Oracle utilities imp ,exp sqlplus has rwxr-x--x privilege

From $ prompt If i type imp it works fine.

But the following fails

$sh imp

Gives :--

/usr/bin/sh imp:

execute permission denied.


If I do the following it works

$sh ( hit enter and go to next line )
imp ( it works )


Question :- How to make

$sh imp ......work
 

8 More Discussions You Might Find Interesting

1. HP-UX

version of the utilities

Hi, Can anyone tell me how i can know the version of the utilities (to be specific "make" and "ar") in HP-UX ver 11.00. thanks, abey. (3 Replies)
Discussion started by: abey
3 Replies

2. UNIX for Dummies Questions & Answers

bc and wc utilities???

Hi, Can anybody explain bc and wc system utilities in Unix? Thanks (6 Replies)
Discussion started by: skyineyes
6 Replies

3. UNIX for Advanced & Expert Users

non GNU utilities

Hi Chaps, Does anyone know of a source of proprietary unix utilities. I often fall into the trap of testing a spot of code on my linux machine, posting the answer in the forums and then realise that the solution may only work with the GNU utils that I use, and not standard posix ones (if there are... (4 Replies)
Discussion started by: wempy
4 Replies

4. UNIX for Advanced & Expert Users

make test fails for DBD::Oracle installation

I've already installed the DBI Perl Module with no issues and now I'm attempting to install the DBD::Oracle driver on a Red Hat Enterprise 4 server and am having some trouble. I've checked through the forums and haven't seen anything helpful at this point. Everything goes fine during the perl... (1 Reply)
Discussion started by: pstrosnyder
1 Replies

5. UNIX for Advanced & Expert Users

utilities

hi experts, i have a file sample: ======= 000123 5 7 0008 00345 5 9 0004 how can i get an output as 123 5 7 8 345 5 9 4 thanks in an advance subhendu (5 Replies)
Discussion started by: subhendu81
5 Replies

6. UNIX for Dummies Questions & Answers

Oracle client install for AIX - WinSCP fails

I am trying to install the oracle client for AIX. I downloaded the client to my Windows machine from Oracle Database 10g Release 2 for AIX5L "Oracle Database 10g Client Release 2 (10.2.0.1.0)". 1. Is this right? (I need 9 or 10 client) It was .gz file that I am now trying to move from... (2 Replies)
Discussion started by: shoefiend
2 Replies

7. Shell Programming and Scripting

Crontab utilities

Hi gurus/lead, I have one doubt in crontab. I have shell script source code in one server. where I don't have priviliges acess R/W the shell script in that server. how can I setup the crontab to pick the code from the other unix server ? whether is there any possibility. in my... (1 Reply)
Discussion started by: ramkumar15
1 Replies

8. Linux

Ansible installation fails on standalone Oracle Linux

I have a standalone Oracle Linux server which has no connectivity to the internet. I was following a blog which directed me to download all ansible dependent setup files and install them using the below command. # yum localinstall -y python-crypto-2.6.1-1.el7.rf.x86_64.rpm... (7 Replies)
Discussion started by: mohtashims
7 Replies
ACC(4)							     Kernel Interfaces Manual							    ACC(4)

NAME
acc - ACC LH/DH IMP interface SYNOPSIS
/sys/conf/SYSTEM: NACC 0 # ACC LH/DH ARPAnet IMP interface PLI YES # LH/DH is connected to a PLI DESCRIPTION
The acc device provides a Local Host/Distant Host interface to an IMP. It is normally used when participating in the DARPA Internet. The controller itself is not accessible to users, but instead provides the hardware support to the IMP interface described in imp(4). When configuring, the imp(NIMP) pseudo-device must also be included. DIAGNOSTICS
acc%d: not alive. The initialization routine was entered even though the device did not autoconfigure. This indicates a system problem. acc%d: can't initialize. Insufficient UNIBUS resources existed to initialize the device. This is likely to occur when the device is run on a buffered data path on an 11/750 and other network interfaces are also configured to use buffered data paths, or when it is configured to use buffered data paths on an 11/730 (which has none). acc%d: imp doesn't respond, icsr=%b. The driver attempted to initialize the device, but the IMP failed to respond after 500 tries. Check the cabling. acc%d: stray xmit interrupt, csr=%b. An interrupt occurred when no output had previously been started. acc%d: output error, ocsr=%b, icsr=%b. The device indicated a problem sending data on output. acc%d: input error, csr=%b. The device indicated a problem receiving data on input. acc%d: bad length=%d. An input operation resulted in a data transfer of less than 0 or more than 1008 bytes of data into memory (according to the word count register). This should never happen as the maximum size of a host-IMP message is 1008 bytes. 3rd Berkeley Distribution July 26, 1987 ACC(4)
All times are GMT -4. The time now is 05:23 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy