That is a number not a string. When a script exits, the shell can return a maximum of an 8 bit number, not a string - ie 0-255 (unsigned). See man 2 wait (what COBOL calls when it fork/execs your script process). Write the return value to a file, then read it in from your COBOL.
Hi ,
Could anyone please tell me about the whole procedure for compiling, linking the cobol program on unix platform. As i am mainframe guy and very new to unix, any help will be very appriciated,
Regards,
-Vinit (2 Replies)
Hello guys,
I'm searching for a good COBOL compiler which runs on linux. In fact I have found one but I'm really lost with its installation!! I don't know how to install it and how it works. In fact I'm not so good in linux and I always have problems with installation, but this time it's... (1 Reply)
Hi,
I am working on a Mainframe to UNIX replatforming project.
we are facing problems with COBOL COMP-3 fields. We are using the Mainframe emulator software to download the data which has COMP-3 fields and using it as input to the same COBOL programs which were copied from Mainframe and did the... (1 Reply)
When I execute a COBOL load module, I get the following error:
$ a.out
IWZ200S Error detected during OPEN for file 'ABE-INPUT'. File status is: 39.
Message routine called from offset 0x38 of routine iwzWriteERRmsg.
iwzWriteERRmsg called from offset 0x3c4 of routine... (3 Replies)
Does anyone use the following Cobol compiler:
RM/COBOL-85 Compiler - Version 5.15.00 for SCO Unix 386.
I am looking for a file that might be part of the distribution named "osmain.o"
Thanks. (0 Replies)
I have some compile programme .crn now I want to run .crn programme on express cobol which allow only *.gnt programme any solution to run *.crn programme (0 Replies)
Dear All,
while installing mfcobol in sco open unix 5 in piv m/cs, when run
#sh ./install
this error massage is comming
load error file lmfnewdb
error code 198 pc=0 call=-1 seg=0
198 load failor
chmod warrning can not acess /opt/lib/mflmf/mflmfdb no such file or directory (error-2)... (0 Replies)
Hello,
I have got a specific requirement of running a COBOL code on EL5. Not sure if GCC includes the compiler for COBOL.
Currently what I can think of installing openCOBOL in EL5 server and hand it over to developers.
From what I think need to do is, compile COBOL code using openCOBOL ... (5 Replies)
Hi guys,
i used the call "sytem" using ... in a cobol program.
At the moment i stoped at an empasse, how cam I retrive the execution's result of unix command?
Explenation, I made an 'pwd' command, and I must to have the directory inside the program.
How can have this result? (2 Replies)
Discussion started by: Prosy60
2 Replies
LEARN ABOUT MOJAVE
tabs
TABS(1) BSD General Commands Manual TABS(1)NAME
tabs -- set terminal tabs
SYNOPSIS
tabs [-n | -a | -a2 | -c | -c2 | -c3 | -f | -p | -s | -u] [+m[n]] [-T type]
tabs [-T type] [+[n]] n1[,n2,...]
DESCRIPTION
The tabs utility displays a series of characters that clear the hardware terminal tab settings then initialises tab stops at specified posi-
tions, and optionally adjusts the margin.
In the first synopsis form, the tab stops set depend on the command line options used, and may be one of the predefined formats or at regular
intervals.
In the second synopsis form, tab stops are set at positions n1, n2, etc. If a position is preceded by a '+', it is relative to the previous
position set. No more than 20 positions may be specified.
If no tab stops are specified, the ``standard'' UNIX tab width of 8 is used.
The options are as follows:
-n Set a tab stop every n columns. If n is 0, the tab stops are cleared but no new ones are set.
-a Assembler format (columns 1, 10, 16, 36, 72).
-a2 Assembler format (columns 1, 10, 16, 40, 72).
-c COBOL normal format (columns 1, 8, 12, 16, 20, 55)
-c2 COBOL compact format (columns 1, 6, 10, 14, 49)
-c3 COBOL compact format (columns 1, 6, 10, 14, 18, 22, 26, 30, 34, 38, 42, 46, 50, 54, 58, 62, 67).
-f FORTRAN format (columns 1, 7, 11, 15, 19, 23).
-p PL/1 format (columns 1, 5, 9, 13, 17, 21, 25, 29, 33, 37, 41, 45, 49, 53, 57, 61).
-s SNOBOL format (columns 1, 10, 55).
-u Assembler format (columns 1, 12, 20, 44).
+m[n], +[n]
Set an n character left margin, or 10 if n is omitted.
-T type
Output escape sequence for the terminal type type.
ENVIRONMENT
The LANG, LC_ALL, LC_CTYPE and TERM environment variables affect the execution of tabs as described in environ(7).
The -T option overrides the setting of the TERM environment variable. If neither TERM nor the -T option are present, tabs will fail.
EXIT STATUS
The tabs utility exits 0 on success, and >0 if an error occurs.
SEE ALSO expand(1), stty(1), tput(1), unexpand(1), termcap(5)STANDARDS
The tabs utility conforms to IEEE Std 1003.1-2001 (``POSIX.1'').
HISTORY
A tabs utility appeared in PWB UNIX. This implementation was introduced in FreeBSD 5.0.
BUGS
The current termcap(5) database does not define the 'ML' (set left soft margin) capability for any terminals.
BSD May 20, 2002 BSD