I've got 2 M5000's connected to a 9985 SAN storage array. I have configured the SAN disks with stmsboot, format and newfs. I can access the same SAN space from both systems. I have created files from both systems on the SAN space.
Question:
Why can't I see the file created with "SystemA" from "SystemB"?
Hi All,
I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX?
Is that going to boot on SAN rootvg volume?
Thanks in advance,
itik (3 Replies)
so we have a solrais 9 system attached to an HP SAN.
we are using sssu to do snap clones every hour.
the only problem is the we get write errors on the solrais system every time we do a snap.
from /var/adm/messages
Apr 21 14:37:48 svr001 scsi: WARNING:... (0 Replies)
Hello everyone
I got several aix boxes with aix 5.3
I got a ibm san ds4500
My question is
How can I do a match between my disks on aix and the san?
I try to do a match with the LUN but for example. In my san I got several 1 LUN and on one of my aix box I got this
If I type lscfg... (4 Replies)
hi all,
have a solaris 9 OS and a SAN disk which used to work fine is not getting picked up by my machine. can anyone point out things to check in order to troubleshoot this ??
thanks in advance. (3 Replies)
Hi all,
My main function is as a DBA. Another person manages the server and the SAN.
I just want to know if I should be worried about high disk I/O or is it irrelevant as the I/O "load balancing" will be "taken care" of by the SAN?
For example, I have hdisk1-5 and I can see that there are... (2 Replies)
Hi,
I have a production solaris 10 SPARC system (portal). Yesterday legato/Networker gave an I/O Error on one of the files on its SAN mounted disk.
I went to that particular file on the system, did an ls and it showed the file. However, ls -l did not work and it said IO error.
... (6 Replies)
Hi All,
I have server : Sun-Fire-V490 configured with Solaris 10 zfs
..
and I have configured three mirror the third one from EMC
storage.
root@server # zpool status -v
pool: rpool
state: ONLINE
status: The pool is formatted using an older on-disk format. The pool can
... (8 Replies)
I am going to do a SAN Array migration and need the sequence of steps required on the Solaris cluster before moving the old array luns to new array luns.
Here are the steps and I need info on the bold points:( I might even be wrong on the sequence of steps please correct me if I am wrong)
1.... (0 Replies)
HACMP two-node cluster with mirrored LVM.
HACMP two-node cluster with two SAN storages mirrored using LVM. Configured 2 disk heartbeat networks - 1 per each SAN storage. While performing redundancy tests. Once one of SAN storage is down - cluster is going to ERROR state. What are the guidelines... (2 Replies)
I am in the market looking to purchase a new E950 server and I am trying to decide between using local SSD drives or SSD based SAN. The application that will be running on this server is read-intensive so I am looking for the most optimal configuration to support this application. There are no... (2 Replies)
Discussion started by: ikx
2 Replies
LEARN ABOUT MINIX
fp
fp(7d) Devices fp(7d)NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)