Sponsored Content
Operating Systems Solaris both mirrors in needs maintenance state. Post 302308230 by incredible on Friday 17th of April 2009 11:49:21 AM
Old 04-17-2009
if there are no hard errors on the disks or incrementing, disk replacement is not needed.
metadetach d30 and clear it
metasync d40
re initialise and attach d30 to d50
Check status again.


if not otherwise replace disk,follow the required procedures when disk replacement
 

10 More Discussions You Might Find Interesting

1. Solaris

DiskSuite: Breaking mirrors.

Ok, so I have a remote system (7 states away) that's using SDS to manage the two 18 gig disks. /, swap, /var, /home, and /opt. The mirroring procedure I created uses installboot to ensure there's a bootblk on both disks of an SDS mirror. The system has a problem booting (can't write to... (21 Replies)
Discussion started by: BOFH
21 Replies

2. Solaris

How to clear maintenance state for apache2 server?

Can any one of you suggest me the method to get apache server in online from maintenance mode. I tried in the following way, but couldn't get that service to online. bash-3.00# svcs -a | grep apache legacy_run 9:51:55 lrc:/etc/rc3_d/S50apache offline 9:51:22... (3 Replies)
Discussion started by: Sesha
3 Replies

3. Linux

Additional mirrors on centos

How can I add additional mirrors to my CENTOS distro, according to this page AdditionalResources/Repositories - CentOS Wiki there are few fedora project repositories I'd like to add any of them but I don't know how? Thank you in advance (0 Replies)
Discussion started by: c0mrade
0 Replies

4. Linux

[Errno 256] No more mirrors to try.

Dear all, CentOS 6 After executing "yum update -y" command I am facing this error. Please help me out. thanks in advance. Full error & error code is given as follow: ... (7 Replies)
Discussion started by: saqlain.bashir
7 Replies

5. Solaris

Help with attaching mirrors

Hi Guys, I need a help with attaching the sub mirrors as it keep throwing errors. I have done solaris live upgrade and it was succesful but it keeps throwing error only for root (s0) and swap (s1)when i try to attach them. For rest of the partitions for slices 3,4,5 on target 1 are able to... (4 Replies)
Discussion started by: phanidhar6039
4 Replies

6. Solaris

Oneway mirrors

All, One-way mirror. Elements of the concat in Last-errd state. What would be the best way to correct it? metastat -s db2test -pc db2test/d220 p 5.0GB db2test/d200 db2test/d219 p 5.0GB db2test/d200 db2test/d218 p 5.0GB db2test/d200 db2test/d217 p 30GB db2test/d200... (0 Replies)
Discussion started by: ossupport55
0 Replies

7. AIX

Open firmware state to running state

Hi Admins, I am having a whole system lpar in open firmware state on HMC. How can I bring it to running state ? Let me know. Thanks. (2 Replies)
Discussion started by: snchaudhari2
2 Replies

8. Solaris

SSH : Restarting too quickly, changing state to maintenance

Hi, I'm new to Solaris. I have an issue with ssh service. When I restart the service it exits with an exit status of 0 $svcadm restart svc:/network/ssh:default $echo $? 0 $ However, the service goes into maintenance mode after restart. I'm able to connect even though the service is in... (3 Replies)
Discussion started by: maverick_here
3 Replies

9. Solaris

Zpool with 3 2-way mirrors in a pool

I have a single zpool with 3 2-way mirrors ( 3 x 2 way vdevs) it has a degraded disk in mirror-2, I know I can suffer a single drive failure, but looking at this how many drive failures can this suffer before it is no good? On the face of it, I thought that I could lose a further 2 drives in each... (4 Replies)
Discussion started by: fishface
4 Replies

10. Solaris

Metastat shows state needs maintenance

Hi, We have a Solaris 10 machine with update 11 and was configured with IBM storage. It was assigned 2 LUNs (each 70GB) which were striped to make it 140GB. we have taken full backup of entire machine and Our storage team replaced IBM storage with Nimble storage (they did storage-level... (6 Replies)
Discussion started by: prvnrk
6 Replies
voldiskadd(8)						      System Manager's Manual						     voldiskadd(8)

NAME
voldiskadd - Adds one or more disks for use with the Logical Storage Manager SYNOPSIS
/usr/sbin/voldiskadd disk-address-list DESCRIPTION
The voldiskadd utility sets up new disks that are added to the system after the initial system installation and configures the disks for use by the Logical Storage Manager. A valid disk label must exist on the disk before using the voldiskadd utility. One or more disks may be specified using a disk-address-list. Disk addresses in the list have the form dskn (for the entire disk) or dsknp (for a specific partition). When specifying multiple disks, use a space between entries. Disk address names relate directly to device names in the /dev/disk directory. For example, here are some valid voldiskadd disk-address-list specifications: # voldiskadd dsk1 # voldiskadd dsk2 dsk3a The file, /etc/vol/disks.exclude, may be used to exclude disks from use by voldiskadd. Each line of the file specifies the name of a disk to exclude (for example, dsk5). The voldiskadd utility prompts the user for a disk group name and disk media name for the disks. If a new disk group name is specified, that disk group is created for the new disks. If no disk group name is specified, the disks are left as unassigned replacement disks for future use. If an existing disk group name is specified, the user is prompted for whether the disks should be designated as spares for the disk group. If a disk is found to already contain non-Logical Storage Manager partitioning, the user is asked whether the disk should be encapsulated. Encapsulation turns each partition of the disk into a volume. A disk should be encapsulated if it contains file systems or data that should not be overwritten. If encapsulation is not desired for a disk, the disk can be initialized as a new disk for use by the Logical Storage Manager. For new disks, all space on the disk becomes free space in the disk's disk group. Context-sensitive help is available at every prompt by typing ?. Also, a list option can be used to get information on available target disks for an operation. The voldiskadd utility supports the following general classes of actions: Initializing a disk with reserved regions and partitions. Disk initialization is performed by calling voldisksetup command. Adding a disk to an existing disk group. This operation can be performed independently of the initialization of the disk drive to add a disk's storage space to a disk group's free space pool. The volassist command may subsequently allocate from that free space. The disk can also be added as a hot spare device. Creating new disk groups in which to import new disks. If no disk group exists for importing disks, the option of creating the disk group is offered. Encapsulating disks that have exist- ing contents. This is the default action for disks that do not have a valid, existing Logical Storage Manager private region, but that do have a disk label. Encapsulation is performed by calling volencap. Reconnecting a drive that was temporarily inaccessible. This situation is detected automatically, by noting that the specified drive has a disk ID that matches a disk media record with no currently associated physical disk. After reconnection, any stale plexes referring the disk are reattached, and any stopped volumes referring the disk are restarted. This reattach action is performed by calling the volrecover script. ERRORS
You may receive the following messages when using the voldiskadd command: Initialization of disk device special-device failed. Error: special-device or an overlapping partition is open. This message indicates that the partition you specified or an overlapping partition on the disk is actively in use. The partition could be a mounted UFS or AdvFS filesystem, initialized as an LSM disk or used as a swap device. special-device is marked in use for fstype in the disklabel. If you continue with the operation you can possibly destroy existing data. Would you like to continue?? [y,n,q,?] (default: n) This message indicates that the fstype of a partition or an overlapping partition is set in the disk label. The voldiskadd command prints this message to warn that a disk partition may have valid data which could be destroyed. If you are sure that the disk partition does not have valid data and that the partition can be added to LSM, you can ignore the warning message by entering y at the prompt. The voldiskadd command will proceed to initialize the disk partition and add it to LSM. FILES
A list of disks to exclude from use by voldiskadd. SEE ALSO
disklabel(8), volassist(8), voldisk(8), voldiskadm(8), voldisksetup(8), voldg(8), volintro(8) voldiskadd(8)