Sponsored Content
Full Discussion: T2000 Hardware RAID
Operating Systems Solaris T2000 Hardware RAID Post 302307604 by incredible on Wednesday 15th of April 2009 11:03:03 PM
Old 04-16-2009
Its hot-swappable. You can just pull out the disk while the system is running or you can bring the system down to the OK> prompt then pull out the disk you want to.
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

How to setup hardware RAID on a T2000

Hello all We've just bought a T2000. It has two disks and I'm trying to figure out how to create a mirror of the boot disk. I understand that I have to boot into single user mode from DVD and then use the raidctl command to set up the mirror and label the volume afterwards. Format returns... (4 Replies)
Discussion started by: soliberus
4 Replies

3. Solaris

T2000 RAID Question

New to the boards here so please bear with me! I have a T2000 server with Solaris 10 installed on it. Disk 0 is the only disk currently being used, as I do NOT have a RAID set up. Disk 1 is just sitting there looking pretty. I'd like to set up a mirrored RAID in order to fully utilize both... (5 Replies)
Discussion started by: phi148
5 Replies

4. Solaris

Raid problem on T2000

Hi all, First post so be gentile :) It's my first time installing Solaris on T2000 server. I have 2 72GB HD's on it. After configuring HW raid and running raidctl command I get this output: bash-3.00# raidctl -l c0t0d0 Volume Size Stripe Status Cache RAID ... (2 Replies)
Discussion started by: Obi-Wan
2 Replies

5. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

6. Solaris

Hardware Raid - LiveUpgrade

Hi, I have a question. Do LiveUpgrade supports hardware raid? How to choose the configuration of the system disk for Solaris 10 SPARC? 1st Hardware RAID-1 and UFS 2nd Hardware RAID-1 and ZFS 3rd SVM - UFS and RAID1 4th Software RAID-1 and ZFS I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies

7. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

8. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

9. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies
vxunreloc(1M)															     vxunreloc(1M)

NAME
vxunreloc - move a hot-relocated subdisk back to its original disk SYNOPSIS
/etc/vx/bin/vxunreloc [-f] [-g diskgroup] [-n dm_name] [-t tasktag] dm_name DESCRIPTION
The Veritas Volume Manager (VxVM) hot-relocation feature can detect an I/O failure in a subdisk, relocate the subdisk, and recover the plex associated with the subdisk. vxunreloc lets you reverse the process and move the hot-relocated subdisks back onto a disk that was replaced after a disk failure. dm_name specifies the disk where the hot-relocated subdisks originally resided. The -n option moves the subdisks to a different disk from where VxVM originally relocated them. For example, when disk03 fails, all the subdisks residing on it are hot-relocated to other disks. After the disk is repaired, it is added back to the disk group using a different name, for example, disk05. If you wanted to move all the hot-relocated subdisks back to the repaired disk, you would enter: /etc/vx/bin/vxunreloc -n disk05 disk03 When vxunreloc moves the hot-relocated subdisks, it moves them to their original offsets. However, if there was a subdisk that occupied part or all of the area on the destination disk, vxunreloc prints an error message and exits. In this situation, you can use the -f option to unrelocate the subdisks to a specified disk, but not to their original offsets. OPTIONS
-f Unrelocates a subdisk to a different offset if unrelocating to the original offset is not possible. -g diskgroup Unrelocates a subdisk from the specified disk group. If this option is not specified, the default disk group is determined using the rules given in the vxdg(1M) manual page. -n dm_name Specifies a new disk name to relocate to a disk with a different name. -t tasktag Specifies a tag to pass to the underlying utility. SUBDISK RECORD FIELDS
orig_dmname When a subdisk is hot-relocated, its original disk media name is stored in the orig_dmname field. When you run the vxunreloc command to move the subdisk back to the original disk (or to a new disk), this field is cleared. Before you run the vxunreloc command, you can do a search on this field to determine the subdisks that originated from a failed disk. For example, the fol- lowing command lists all the subdisks that were hot-relocated from mydg01 in the disk group mydg. Note that you must prefix the field name with "sd_" for the command to work. vxprint -g mydg -se 'sd_orig_dmname="mydg01"' orig_dmoffset When a subdisk is hot-relocated, its offset into the original disk is stored in the orig_dmoffset field. When you run vxunreloc to move the subdisk to the original disk, or to a new disk, this field is zeroed. The following command lists a hot-relocated subdisk which originally resided at disk10 at offset 1000. Again note that you must prefix the field names with "sd_" for the command to work. vxprint -g dg01 -se 'sd_orig_dmname="disk10" && sd_orig_dmoffset=1000' EXIT CODES
If the operation fails, vxunreloc exits with a non-zero status. A non-zero exit code is not a complete indicator of the problems encoun- tered, but rather denotes the first condition that prevented further execution of the utility. See vxintro(1M) for a list of standard exit codes. SEE ALSO
vxassist(1M), vxintro(1M), vxmake(1M), vxprint(1M), vxrelocd(1M), vxsd(1M), vxsparecheck(1M) VxVM 5.0.31.1 24 Mar 2008 vxunreloc(1M)