Sponsored Content
Operating Systems AIX Problem mapping LUN disk from VIOS to the LPAR Post 302306253 by raba on Sunday 12th of April 2009 01:58:07 AM
Old 04-12-2009
hi,
1. depending on the type of SAN storage, usually the LUN id can be found with lscfg -l hdisk##

2. you can set the pvid like this: chdev -dev hdisk## -attr pv=yes

hope this helps

Randy
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

LUN mapping

Hi, We recently purchased a 3 tb RAID. In the setup, it created 2 slices, one 2 tb and one 1 tb slice. Right now only the 2 tb slice is visible when booting up. I was told that the second slice needs to be mapped to a lun and a port like the first slice is. Does anyone know how I would go... (1 Reply)
Discussion started by: user23
1 Replies

2. AIX

LPAR and vio disk mapping

We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Discussion started by: daveisme
4 Replies

3. AIX

VIOS to lpar Mapping

Hello, I have created mapping of 2 virtual adapters for Lpars using following command: mkvdev -vdev ipanalyzerlv1 -vadapter vhost11 mkvdev -vdev ipanalyzerlv -vadapter vhost13 The above two commands were succesfull but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Discussion started by: Vit0_Corleone
3 Replies

4. AIX

What's the difference between VIOS and LPAR?

Hi All, Besides the licenses on VIO and LPAR. What's the main difference with the two? I have installed VIO, my manager told me so, because it's like a free hypervisor but I never installed LPAR before. How do you install it? And if you can give more info on the two, that would be great. ... (5 Replies)
Discussion started by: itik
5 Replies

5. AIX

Sharing lun between 2 LPAR

Hi, I would like to know how to share lun in between 2 lpars. I have run tbe below command on vio server. /usr/sbin/chdev -l hdisk1 -a reserve_policy=no_reserve after above command I am able to assign lun on one Lpar. but it is not visible to other lpar. even after this I have run... (3 Replies)
Discussion started by: manoj.solaris
3 Replies

6. AIX

VIOS FC Mapping/NPIV questions

Please forgive me here as I don't fully understand what I am talking about here so if I use the wrong terminology please overlook me. We have multiple AIX LPARs on the managed system with two VIO Servers. A Co-Worker and I are trying to set up a new LPAR client (The guy that knows this is out)... (14 Replies)
Discussion started by: juredd1
14 Replies

7. AIX

List LPAR from VIOS

Hi guys, does anyone know how to get a list of the LPAR running on VIOS? Thanks! (5 Replies)
Discussion started by: cecco16
5 Replies

8. AIX

VIOS LPAR Error 0518

I am trying to install AIX 5.3 on one of the LPARs through VIOS but I get this error 0518 Reference Code Selection 0518 (Time stamp: 12/18/12 12:10:20 AM UTC) Starting kernel (Time stamp: 12/18/12 12:10:15 AM UTC) AIX is starting. (Time stamp: 12/18/12 12:10:15 AM... (10 Replies)
Discussion started by: filosophizer
10 Replies

9. AIX

Moving VIOS, LPAR's, HMC to different subnet

Hi, Just joined to new company with one Power 720 Express (8202-E4C) server and have no much experience with IBM systems. I am trying to move everything I mentioned to different subnet as required by customer contract (currently sitting on same subnet as company lan). Access to this subnet will... (8 Replies)
Discussion started by: spricer
8 Replies

10. AIX

VIOS: Extend virtual disk assigned to running lpar?

Hello, VIOS 2.2.1.4 using IVM. I'm trying to extend a virtual disk assigned to a running lpar so that I can expand the lpar's datavg and grow some filesystems for the user. Storage admin expanded the lun and new size was reflected in VIO right away. I then needed the storage pool to... (2 Replies)
Discussion started by: j_aix
2 Replies
norewind_close_disabled(5)					File Formats Manual					norewind_close_disabled(5)

NAME
norewind_close_disabled - determine whether access to tape device special files without the no-rewind-on-close option is allowed VALUES
Default Allowed values DESCRIPTION
Note: this tunable was named in releases prior to HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on, the tape driver will fail any open on a tape device special file that does not have the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued accidentally from this system on close, possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. EXAMPLES
Query the current value of the tunable: Set the value of the tunable to To save the value of the tunable across reboots: WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters norewind_close_disabled(5)
All times are GMT -4. The time now is 07:41 PM.