I am using compaq t5207tu model with 60gb harddisk and 2.5gb RAM.Its dual boot-Windows XP and Solaris. I tried installing SUN xVM on solaris to make client -server architecture (32 bit processor and 32 bit OS ) -guest OS (solaris 10)on host OS(Solaris 10). But whenever i try to install virtualbox, i get following below error...Plz advice
Last edited by DukeNuke2; 04-11-2009 at 05:11 AM..
Hi, folks.
Sorry for bothering, but maybe someone could help me please.
The problem is the following:
there is some script that copies files from local file system to AFS. The copying is performed with dd command.
The script copies data into some AFS volumes.
The problem appeared with one... (0 Replies)
Hi guys
I'm going to be moving a linux box into collocation to support the growing demands of my sites and have been trying to figure out if Xen is right for me. I'd appreciate hearing some real-world experience with the overhead involved and the optimal ways to slice up a box. Right now I feel... (1 Reply)
Hello,
I need to build a server with both solaris and linux guest VM using full virt on x64.
The guest os are solaris 10 (not opensolaris) and linux RedHat (Centos) and Suse.
I really cant make run a solaris 10 domU on Linux (hang after grub loader ..... ) Dom0 neither on opensolaris 11 xvm... (0 Replies)
1) when user login to the server the session got colosed. How will resolve?
2) While firing the command ls -l we are not able to see the any files in the director. but over all view the file system using the command df -g it is showing 91% used. what will be the problem?
Thanks in advance. (1 Reply)
Dear ALL.
I installed AIX OS on customer sites.
but Only one site is too slow when I connected telnet, ftp..
Ping is too fast. but telnet and FTP is not connected..
of course i check the configuration file on aix but it's normal.
Do any Idea??
thanks in advance.
- Jun - (3 Replies)
Hi,
This is rather a question from a "user" than from a sys admin, but I think this forum is apropriate for the question.
I have an adress with automatic email forwarding and for some senders (two hietherto), emails are bouncing. This has really created a lot of problems those two time so I... (0 Replies)
Server is accessible only via IPMI. SSH and web control panel is timeout. Takes several hours. Server dont have high load or suspicious processes.
I checked /etc/hosts.deny and restarted ssh, but nothing :( (0 Replies)
I don't know if you guys get this problem sometimes at Terminal but I had been having this problem since yesterday :( Maybe I overdid the Terminal. Even the codes that used to work doesn't work anymore.
Here is what 's happening:
* I wanted to remove lines containing digits so I used this... (25 Replies)
Hi everyone,
I am experiencing discontinuity of Internet service, this started 1 month ago. Everything worked very well for 1 year of intensive use, but now, I have problems reaching my gateway.
The gateway is not my router but a node belonging to my ISP and I share the same public IP with... (3 Replies)
Discussion started by: remic
3 Replies
LEARN ABOUT LINUX
usoc
usoc(7D) Devices usoc(7D)NAME
usoc - universal serial optical controller for Fibre Channel arbitrated loop (SOC+) device driver
DESCRIPTION
The Fibre Channel adapter is an SBus card that implements two full duplex Fibre Channel interfaces. Each interface can connect to a Fibre
Channel arbitrated loop (FC-AL). The usoc device driver is a nexus driver and implements portions of the FC-2 and FC-4 layers of FC-AL.
FILES
/kernel/drv/usoc
32-bit ELF kernel module
/kernel/drv/sparcv9/usoc
64-bit ELF kernel module
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Architecture |SPARC |
+-----------------------------+-----------------------------+
|Interface stability |Unknown |
+-----------------------------+-----------------------------+
|Availability |SUNWusoc |
+-----------------------------+-----------------------------+
SEE ALSO fctl(7D), sbus(4), fcp(7D), fp(7D), ssd(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Channel Loop Attachment (FC-FLA), NCITS TR-20:1998
DIAGNOSTICS
The following messages are logged and may also appear on the system console. On the console these messages are preceded by:
usoc%d:
where
usoc%d:
is the per-port instance number of the usoc controller.
Fibre Channel is ONLINE
The Fibre Channel loop is now online.
Fibre Channel Loop is ONLINE
The Fibre Channel loop is now online.
Fibre Channel Loop is OFFLINE
The Fibre Channel loop is now offline.
attach failed: device in slave-only slot.
Move soc+ card to another slot.
attach failed: alloc soft state.
Driver did not attach, devices will be inaccessible.
attach failed: bad soft state.
Driver did not attach, devices will be inaccessible.
attach failed: unable to map eeprom
Driver was unable to map device memory; check for bad hardware. Driver did not attach to device, devices will be inaccessible.
attach failed: unable to map XRAM
Driver was unable to map device memory; check for bad hardware. Driver did not attach to device, devices will be inaccessible.
attach failed: unable to map registers
Driver was unable to map device registers; check for bad hardware. Driver did not attach to device, devices will be inaccessible.
attach failed: unable to access status register
Driver was unable to map device registers; check for bad hardware. Driver did not attach to device, devices will be inaccessible.
attach failed: unable to install interrupt handler
Driver was not able to add the interrupt routine to the kernel. Driver did not attach to device, devices will be inaccessible.
attach failed: unable to access host adapter XRAM
Driver was unable to access device RAM; check for bad hardware. Driver did not attach to device, devices will be inaccessible.
attach failed: unable to write host adapter XRAM
Driver was unable to write device RAM; check for bad hardware. Driver did not attach to device, devices will be inaccessible.
attach failed: read/write mismatch in XRAM
Driver was unable to verify device RAM; check for bad hardware. Driver did not attach to device, devices will be inaccessible.
SunOS 5.10 20 Jul 1999 usoc(7D)