Sponsored Content
Full Discussion: interface ce1 up-down
Operating Systems Solaris interface ce1 up-down Post 302304262 by Renjesh on Monday 6th of April 2009 02:34:02 AM
Old 04-06-2009
Yes,Blow torch is right. You could check the link and duplex settings too.
My reply came from a personal experience where i found the cable faulty..Smilie
 

9 More Discussions You Might Find Interesting

1. Solaris

ce0 and ce1 have the same mac address

i have ce0 and ce1 online, on 2 different networks. im getting a message that says one nic is trying to assume the others IP or something to thta effect. I do ifconfig -a and i see they have the same mac. How do i deal with this? Solaris 9 i beleive 04/04 Thanks, Brian (2 Replies)
Discussion started by: BG_JrAdmin
2 Replies

2. Solaris

interface may off

Dear ALL, my server give me messages like below: Apr 20 21:33:09 TAISERVER in.routed: interface bge3 to 192.168.11.22 turned off I check with ifconfig,but nothing error that,how can make it solve...thanks for your help. (7 Replies)
Discussion started by: fredginting
7 Replies

3. Solaris

SunFire V440 Quad gigabit ce1 won't run Gig

Hi there. My first time posting so apologies for any indescretions in advance. :o I've got two SunFire V440 servers running Solaris 5v10. Both have a quad Gigabit ethernet card fitted, both have the same symptom; that is, I can't get the first port ce1 to run Gigabit. Motherboard ports are ce0 and... (10 Replies)
Discussion started by: fixit9660
10 Replies

4. Solaris

Command line Interface or GUI Interface not shown on solaris

Dear all, I am a newbie in solaris and I need your advice. I have a Solaris version 5.9 installed on Sunfire V240. I am able to ssh the machine from putty remotely. My problem is that I cannot see the display from KVM switch I have connected to it. I need also to be able to see the GUI... (2 Replies)
Discussion started by: mbouster
2 Replies

5. SCO

Change SCO - GUI or Desktop interface to DOS based interface

Hi all I have installed a demo version of SCO OpenServer 5.0.2, I finally found it is Desktop Interface, I would like to know how to change its interface to dos based interface? If you have any ideas, please tell me then. Thank you (2 Replies)
Discussion started by: TinhNhi
2 Replies

6. IP Networking

Need a bridge from an ethernet interface to a serial interface

This is my situation DOS pc serial cable (sl0) Linux Pc eth1 192.168.0.10 <-------------------->192.168.0.2 <------------>192.168.0.1 (router) I connected the linux pc and the dos pc with a SLIP (serial line internet protocol), so they can communicate in the sl0 interface. ... (3 Replies)
Discussion started by: mghis
3 Replies

7. UNIX for Dummies Questions & Answers

Interface

Hi All, How to check whether a Interface has a single port or dual port.Thanks in advance. (5 Replies)
Discussion started by: rama krishna
5 Replies

8. UNIX for Dummies Questions & Answers

Solaris Logic to transmit traffic to physical interfaces ( eg ce0 and ce1)

Just wanted to understand what is the logic being used by Solaris(kernel) to transmit data/traffic on physical interfaces. I have seen most of the time traffic is being sent to interface ce0 and sometime to ce1. I have removed ip address from below command for some reason. netstat -rn ... (3 Replies)
Discussion started by: nadeemahmed
3 Replies

9. UNIX for Dummies Questions & Answers

Adding a network interface to a bonded interface

I have a RHEL 5 system with a bonded interface configure using only one network port (eth0). So I have config file for ifcfg-bond0 and ifcfg-eth. I'd like to configure eth5 to be the second SLAVE in the bond. My question is, after I modify ifcfg-eth5, can I add eth5 to the bond0 interface without... (1 Reply)
Discussion started by: westmoreland
1 Replies
afe(7D) 							      Devices								   afe(7D)

NAME
afe - ADMtek Fast Ethernet device driver SYNOPSIS
/dev/afe DESCRIPTION
The afe driver is a multi-threaded, loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface dlpi(7P) on ADMtek (now Infineon) Centaur and Comet Fast Ethernet controllers. APPLICATION PROGRAMMING INTERFACE
The afe driver can be used as either a "style 1" or a "style 2" Data Link Service Provider. Physical points of attachment (PPAs) are inter- preted as the instance number of the afe controller as assigned by the Solaris operating environment. The relevant fields returned as part of a DL_INFO_ACK response are: o Maximum SDU is 1500. o Minimum SDU is 0. o The dlsap address length is 8. o MAC type is DL_ETHER. o SAP length is -2. The 6-byte physical address is followed immediately by a 2-byte SAP. o Service mode is DL_CLDLS. o Broadcast address is the 6-byte Ethernet broadcast address (ff:ff:ff:ff:ff:ff). If the SAP provided is zero, then IEEE 802.3 mode is assumed and outbound frames will have the frame payload length written into the type field. Likewise, inbound frames with a SAP between zero and 1500 are interpreted as IEEE 802.3 frames and delivered to any streams that are bound to SAP zero (the 802.3 SAP). PROPERTIES
The following properties may be configured using either ndd(1M) or the afe.conf configuration file as described by driver.conf(4): adv_autoneg_cap Enables (default) or disables IEEE 802.3u auto-negotiation of link speed and duplex settings. If enabled, the device negotiates among the supported (and configured, see below) link options with the link partner. If disabled, at least one of the link options below must be specified. The driver selects the first enabled link option according to the IEEE 802.3u specified preferences. adv_100T4_cap Enables the 100 BaseT4 link option. (Note that most hardware does not support this unusual link style. Also, this uses two pairs of wires for data, rather than one.) adv_100fdx_cap Enables the 100 Base TX full-duplex link option. (This is generally the fastest mode if both link partners support it. Most modern equipment supports this mode.) adv_100hdx_cap Enables the 100 Base TX half-duplex link option. (Typically used when the link partner is a 100 Mbps hub.) adv_10fdx_cap Enables the 10 Base-T full-duplex link option. (This less-frequently used mode is typically used when the link partner is a 10 Mbps switch.) adv_10hdx_cap Enables the 10 Base-T half-duplex link option. (This is the fall-back when no other option is available. It is typically used when the link partner is a 10 Mbps hub or is an older network card.) ATTRIBUTES
See attributes(5) for a description of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SPARC, x86 | +-----------------------------+-----------------------------+ |Interface Stability |Committed | +-----------------------------+-----------------------------+ FILES
/dev/afe Special character device. /kernel/drv/afe 32-bit driver binary (x86). /kernel/drv/amd64/afe 64-bit driver binary (x86). /kernel/drv/sparcv9/afe 64-bit driver binary (SPARC). /kernel/drv/afe.conf Configuration file. SEE ALSO
ndd(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P) IEEE 802.3 -- Institute of Electrical and Electronics Engineers, 2002 SunOS 5.11 1 Apr 2007 afe(7D)
All times are GMT -4. The time now is 03:55 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.