04-03-2009
Veritas Cluster Server Management Console IP Failover
I have just completed a first RTFM of "Veritas Cluster Server Management Console Implementation Guide" 5.1, with a view to assessing it to possibly make our working lives easier.
Unfortunately, at my organisation, getting a test installation would be worse than pulling teeth, so I can't just go and suck it and see.
If one uses this product to failover a SG from a local cluster to a remote one cluster, how are the changes to the attributes of the IP resources handled?
e.g.
local SG = sg_local
IP resource name = ip_local
ip_local has attributes address=192.168.1.2, netmask 255.255.255.0
But suppose I fail sg_local to a remote cluster at our DR site, we require
address = 168.1.2.3, netmask 255.255.255.0
Can one configure this information?
Currently we do such failover manually, and we maintain the "DR-version" of main.cf on the target DR cluster.
10 More Discussions You Might Find Interesting
1. High Performance Computing
Hello,
This might not be the right place to post my questions.
- I installed VCS 5.0 on the 2 nodes. What's next? I want to test the HA of NFS: i.e. the shared disk always accessible if one node goes down. How to do that?
- The management console was not installed. This is the GUI to manage... (2 Replies)
Discussion started by: melanie_pfefer
2 Replies
2. Solaris
Is it possible to configure veritas cluster server using 2 Ldoms on same host? I just want to test and learn VCS. We can do a cluster (sun cluster3.2 ) in a box using 2 Ldoms but i 'm not sure if thats possible with veritas cluster or not ? (1 Reply)
Discussion started by: fugitive
1 Replies
3. Solaris
Hi,
We have two sun SPARC server in Clustered (Sun Cluster 3.1). For some reason, System 1 failed over to System 2. Where can I find the logs which could tell me the reason for this failover?
Thanks (5 Replies)
Discussion started by: Mack1982
5 Replies
4. Solaris
Yesterday my customer told me to expect a vcs upgrade to happen in the future. He also plans to stop using HDS and move to EMC.
Am thinking how to migrate to sun cluster setup instead.
My plan as follows leave the existing vcs intact as a fallback plan.
Then install and build suncluster on... (5 Replies)
Discussion started by: sparcguy
5 Replies
5. Gentoo
How to failover the cluster ? GNU/Linux
By which command,
My Linux version
2008 x86_64 x86_64 x86_64 GNU/Linux
What are the prerequisites we need to take while failover ?
if any
Regards (3 Replies)
Discussion started by: sidharthmellam
3 Replies
6. UNIX for Advanced & Expert Users
Hello,
Usually I use "vxresize" to grow vxfs directory in a stand-alone server without any problems, but I am just told to grow vxfs directorys in Veritas Cluster nodes.
Since I never done it before, would like to ask all the experts here to make sure the concept and steps will be fine... (1 Reply)
Discussion started by: sunnychen98
1 Replies
7. Solaris
Hello experts -
I am planning to install a Sun cluster 4.0 zone cluster fail-over. few basic doubts.
(1) Where should i install the cluster s/w binaries ?. ( global zone or the container zone where i am planning to install the zone fail-over)
(2) Or should i perform the installation on... (0 Replies)
Discussion started by: NVA
0 Replies
8. Solaris
Until I really began to explore the practical implications of using ZFS with VCS, I would not have necessarily realised the obstacles that would be put in my path. Data integrity is a must-have for storage in a shared host environment, so it surprised me to learn as I opened this particular... (0 Replies)
Discussion started by: cambridge
0 Replies
9. Red Hat
Hi Guys,
I am not much aware of clusters but i have few questions can someone provide the overview as it would be very helpful for me.
How can i perform cluster failover test to see all the services are failing back to other node ? If it is using veritas cluster then what kind of... (2 Replies)
Discussion started by: munna529
2 Replies
10. UNIX for Beginners Questions & Answers
Hi Experts,
I wanted to extend a veritas file system which is running on veritas cluster and mounted on node2 system.
#hastatus -sum
-- System State Frozen
A node1 running 0
A node2 running 0
-- Group State
-- Group System Probed ... (1 Reply)
Discussion started by: Skmanojkum
1 Replies
LEARN ABOUT SUNOS
netmasks
netmasks(4) File Formats netmasks(4)
NAME
netmasks - network mask database
SYNOPSIS
/etc/inet/netmasks
/etc/netmasks
DESCRIPTION
The netmasks file contains network masks used to implement IP subnetting. It supports both standard subnetting as specified in RFC-950 and
variable length subnetting as specified in RFC-1519. When using standard subnetting there should be a single line for each network that is
subnetted in this file with the network number, any number of SPACE or TAB characters, and the network mask to use on that network. Network
numbers and masks may be specified in the conventional IP `.' (dot) notation (like IP host addresses, but with zeroes for the host part).
For example,
128.32.0.0 255.255.255.0
can be used to specify that the Class B network 128.32.0.0 should have eight bits of subnet field and eight bits of host field, in addition
to the standard sixteen bits in the network field.
When using variable length subnetting, the format is identical. However, there should be a line for each subnet with the first field being
the subnet and the second field being the netmask that applies to that subnet. The users of the database, such as ifconfig(1M), perform a
lookup to find the longest possible matching mask. It is possible to combine the RFC-950 and RFC-1519 form of subnet masks in the net-
masks file. For example,
128.32.0.0 255.255.255.0
128.32.27.0 255.255.255.240
128.32.27.16 255.255.255.240
128.32.27.32 255.255.255.240
128.32.27.48 255.255.255.240
128.32.27.64 255.255.255.240
128.32.27.80 255.255.255.240
128.32.27.96 255.255.255.240
128.32.27.112 255.255.255.240
128.32.27.128 255.255.255.240
128.32.27.144 255.255.255.240
128.32.27.160 255.255.255.240
128.32.27.176 255.255.255.240
128.32.27.192 255.255.255.240
128.32.27.208 255.255.255.240
128.32.27.224 255.255.255.240
128.32.27.240 255.255.255.240
128.32.64.0 255.255.255.192
can be used to specify different netmasks in different parts of the 128.32.0.0 Class B network number. Addresses 128.32.27.0 through
128.32.27.255 have a subnet mask with 28 bits in the combined network and subnet fields (often referred to as the subnet field) and 4 bits
in the host field. Furthermore, addresses 128.32.64.0 through 128.32.64.63 have a 26 bits in the subnet field. Finally, all other
addresses in the range 128.32.0.0 through 128.32.255.255 have a 24 bit subnet field.
Invalid entries are ignored.
SEE ALSO
ifconfig(1M), inet(7P)
Postel, Jon, and Mogul, Jeff, Internet Standard Subnetting Procedure, RFC 950, Network Information Center, SRI International, Menlo Park,
Calif., August 1985.
V. Fuller, T. Li, J. Yu, K. Varadhan, Classless Inter-Domain Routing (CIDR): an Address Assignment and Aggregation Strategy, RFC 1519,
Network Information Center, SRI International, Menlo Park, Calif., September 1993.
T. Pummill, B. Manning, Variable Length Subnet Table For IPv4, RFC 1878, Network Information Center, SRI International, Menlo Park, Calif.,
December 1995.
NOTES
/etc/inet/netmasks is the official SVr4 name of the netmasks file. The symbolic link /etc/netmasks exists for BSD compatibility.
SunOS 5.10 7 Jan 1997 netmasks(4)