Sponsored Content
Operating Systems Solaris Unable to access 3500 FC array. Where is the problem?.. Post 302302186 by DukeNuke2 on Monday 30th of March 2009 09:50:07 AM
Old 03-30-2009
have a look at the commands "cfgadm", "luxadm" and "fcinfo".
 

10 More Discussions You Might Find Interesting

1. Solaris

Booting problem on Sun 3500

Hi, I have a Sun 3500 server on which i installed solaris 8 and have also installed veritas 4.0 on it. i dont know why from the time i have built this server whenever i try to boot it, the server doesnot come back smooth.... i have got to connect a laptop to the serial port of the server and... (3 Replies)
Discussion started by: ishila
3 Replies

2. Solaris

Unable to access home area

Good morning, I have a solaris 8 machine (Sunblade 1000) that is configured with NIS, I have checked everything I can think of to make sure everything is correctly configured which it appears it is but when I try to log into CDE it says it is unable to access my home area and it also does the... (1 Reply)
Discussion started by: Mr Pink
1 Replies

3. Shell Programming and Scripting

Unable to access variable outside loop

I am unable to access the value set inside the loop from outside loop . Thought of taking this to forum , I had seen other replies also , where a pipe takes the execution to another shell and mentioned thats the reason we do not get the variable outside loop . But I am getting an issue and I am... (1 Reply)
Discussion started by: Armaan_S
1 Replies

4. Solaris

unable to access infodoc!!

Hi, I am refered to see Infodoc 80854. but I am not able to access from sun.com. Is there any precedure to view these?. Please guide me. Thanks in advance. (1 Reply)
Discussion started by: bpsunadm
1 Replies

5. HP-UX

Unable to access TAR file

hi friends, I am using hp unix HP-UX B.11.11 .. Generally i do the compression to maintain the space availability . To compress the files first i used the TAR to collect all the files. it has done fine. when i am using command ls in the folder which has TAR file , it shows the TAR... (2 Replies)
Discussion started by: rdhaprakasam
2 Replies

6. Shell Programming and Scripting

problem in access in array variables

hi all, its me again!!! i've requirement like this: i want to create a file & an array with its name having the filename as its substring. here is the test script!! #!/bin/bash touch $1 declare -a $1_rec; echo -n "$1_rec: " read $1_rec; echo $]; now see output: this is when i enter... (7 Replies)
Discussion started by: tprayush
7 Replies

7. AIX

P550 Unable to access Console

I have recently aquired the following machine: IBM,9113-550 Up until yesterday we could connect a dumb terminal to serial port 1 and get console login. However the dumb terminal died. We are now using a laptop with a null modem cable attached to serial port 1. This works perfectly for all of... (1 Reply)
Discussion started by: rsw7724
1 Replies

8. Shell Programming and Scripting

problem access array outside of loop in bash

Below is a test script I was trying to use so that I could understand why the logic was not working in a larger script. While accessing and printing array data inside the while loop, everything is fine. Outside the loop, i guess everything is null?? The for loop that is meant to cycle... (4 Replies)
Discussion started by: adlmostwanted
4 Replies

9. Solaris

Booting problem on Sun 3500

Booting problem on Sun 3500 Hi, I have a Sun 3500 server on which i installed solaris 5.2 installed . i dont know why from the time i have built this server whenever i try to boot it, the server doesnot come back smooth.i got a message Sync file system than restart some times showing ok... (2 Replies)
Discussion started by: najeer
2 Replies

10. Shell Programming and Scripting

Unable To access array in awk

Hi, i have the following code in which i am passing array tldn in awk using -v option & despite of that condition is not getting matched,can somebody suggest how to handle shell arrays in awk tcount=(9875 9667) awk -F"\t" -v ltldn="${tldn}" 'NR==FNR {POSTPAIDMDNS=$2"|"$3;next} ... (6 Replies)
Discussion started by: siramitsharma
6 Replies
cfgadm_scsi(1M) 					  System Administration Commands					   cfgadm_scsi(1M)

NAME
cfgadm_scsi - SCSI hardware specific commands for cfgadm SYNOPSIS
/usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option] -c function ap_id... /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option] -x hardware_function ap_id... /usr/sbin/cfgadm [-v] [-a] [-s listing_option] [-o hardware_option] [-l [ap_id | ap_type ... ]] /usr/sbin/cfgadm [-v] [-o hardware_option] -t ap_id... /usr/sbin/cfgadm [-v] [-o hardware_option] -h [ap_id...] DESCRIPTION
The SCSI hardware specific library /usr/lib/cfgadm/scsi.so.1 provides the functionality for SCSI hot-plugging through the cfgadm(1M) com- mand. cfgadm operates on attachment points, which are locations in the system where hardware resources can be dynamically reconfigured. Refer to cfgadm(1M) for information regarding attachment points. For SCSI hot-plugging, each SCSI controller is represented by an attachment point in the device tree. In addition, each SCSI device is rep- resented by a dynamic attachment point. Attachment points are named through ap_ids. Two types of ap_ids are defined: logical and physical. The physical ap_id is based on the physical pathname, whereas the logical ap_id is a shorter more user-friendly name. For SCSI con- trollers, the logical ap_id is usually the corresponding disk controller number. For example, a typical logical ap_id would be c0. SCSI devices are named relative to the controller ap_id. Thus if a disk device is attached to controller c0, its ap_id can be: c0::dsk/c0t0d0 where dsk/c0t0d0 identifies the specific device. In general, the device identifier is derived from the corresponding logical link for the device in /dev. For example, a SCSI tape drive logical ap_id could be c0::rmt/0. Here c0 is the logical ap_id for the SCSI controller and rmt/0 is derived from the logical link for the tape drive in /dev/rmt. If an identifier can not be derived from the link in /dev, a unique identifier will be assigned to it. For example, if the tape device has no link in /dev, it can be assigned an ap_id of the form c0::st3 where st3 is a unique internally generated identifier. A simple listing of attachment points in the system will include attachment points at SCSI controllers but not SCSI devices. Use the -a flag to the list option (-l) to list SCSI devices as well. For example: # cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown sysctrl0:slot0 cpu/mem connected configured ok sysctrl0:slot1 sbus-upa connected configured ok To list SCSI devices in addition to SCSI controllers: # cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t14d0 disk connected configured unknown c0::dsk/c0t11d0 disk connected configured unknown c0::dsk/c0t8d0 disk connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::rmt/0 tape connected configured unknown sysctrl0:slot0 cpu/mem connected configured ok sysctrl0:slot1 sbus-upa connected configured ok Refer to cfgadm(1M) for more information regarding listing attachment points. The receptacle and occupant state for attachment points at the SCSI controller have the following meanings: empty not applicable disconnected bus quiesced (I/O activity on bus is suspended) connected bus active configured one or more devices on the bus is configured unconfigured no device on the bus is configured The corresponding states for individual SCSI devices are: empty not applicable disconnected bus to which the device is attached is quiesced connected bus to which device is attached is active configured device is configured unconfigured device is not configured OPTIONS
cfgadm defines several types of operations besides listing (-l).These operations include testing, (-t), invoking configuration state changes, (-c), invoking hardware specific functions (-x), and obtaining configuration administration help messages (-h). -c function The following generic commands are defined for the SCSI hardware specific library: For SCSI controller attachment points, the following configuration state change operations are supported: connect Unquiesce the SCSI bus. disconnect Quiesce the bus (suspend I/O activity on bus). Incorrect use of this command can cause the system to hang. See NOTES. configure Configure new devices on SCSI bus. unconfigure Unconfigure all devices connected to bus. The following generic commands are defined for SCSI devices: configure configure a specific device unconfigure unconfigure a specific device -f When used with the disconnect command, forces a quiesce of the SCSI bus, if supported by hardware. Incorrect use of this command can cause the system to hang. See NOTES. -h ap_id SCSI specific help can be obtained by using the help option with any SCSI attachment point. -o hardware_option No hardware specific options are currently defined. -s listing_option Attachment points of class scsi can be listed by using the select sub-option. Refer to the cfgadm(1M) man page for additional information. -t ap_id No test commands are available at present. -x hardware_function Some of the following commands can only be used with SCSI controllers and some only with SCSI devices. In the following, controller_ap_id refers to an ap_id for a SCSI controller, for example, c0. device_ap_id refers to an ap_id for a SCSI device, for example: c0::dsk/c0dt3d0. The following hardware specific functions are defined: insert_device controller_ap_id Add a new device to the SCSI controller, controller_ap_id. This command is intended for interactive use only. remove_device device_ap_id Remove device device_ap_id. This command is intended for interactive use only. replace_device device_ap_id Remove device device_ap_id and replace it with another device of the same kind. This command is intended for interactive use only. reset_device device_ap_id Reset device_ap_id. reset_bus controller_ap_id Reset bus controller_ap_id without resetting any devices attached to the bus. reset_all controller_ap_id Reset bus controller_ap_id and all devices on the bus. EXAMPLES
Example 1: Configuring a Disk The following command configures a disk attached to controller c0: # cfgadm -c configure c0::dsk/c0t3d0 Example 2: Unconfiguring a Disk The following command unconfigures a disk attached to controller c0: # cfgadm -c unconfigure c0::dsk/c0t3d0 Example 3: Adding a New Device The following command adds a new device to controller c0: # cfgadm -x insert_device c0 The system responds with the following: Adding device to SCSI HBA: /devices/sbus@1f,0/SUNW,fas@e,8800000 This operation will suspend activity on SCSI bus c0 Continue (yes/no)? Enter: y The system responds with the following: SCSI bus quiesced successfully. It is now safe to proceed with hotplug operation. Enter y if operation is complete or n to abort (yes/no)? Enter: y Example 4: Replacing a Device The following command replaces a device attached to controller c0: # cfgadm -x replace_device c0::dsk/c0t3d0 The system responds with the following: Replacing SCSI device: /devices/sbus@1f,0/SUNW,fas@e,8800000/sd@3,0 This operation will suspend activity on SCSI bus: c0 Continue (yes/no)? Enter: y The system responds with the following: SCSI bus quiesced successfully. It is now safe to proceed with hotplug operation. Enter y if operation is complete or n to abort (yes/no)? Enter: y Example 5: Encountering a Mounted File System While Unconfiguring a Disk The following command illustrates encountering a mounted file system while unconfiguring a disk: # cfgadm -c unconfigure c1::dsk/c1t0d0 The system responds with the following: cfgadm: Component system is busy, try again: failed to offline: /devices/pci@1f,4000/scsi@3,1/sd@1,0 Resource Information ------------------ -------------------------- /dev/dsk/c1t0d0s0 mounted filesystem "/mnt" FILES
/usr/lib/cfgadm/scsi.so.1 hardware specific library for generic SCSI hot-plugging ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm(1M), luxadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5) NOTES
The disconnect (quiesce) operation is not supported on controllers which control disks containing critical partitions such as root (/), /usr, swap, or /var. The disconnect operation should not be attempted on such controllers. Incorrect usage can result in a system hang and require a reboot. Hotplugging operations are not supported by all SCSI controllers. WARNINGS
The connectors on some SCSI devices do not conform to SCSI hotplug specifications. Performing hotplug operations on such devices can cause damage to the hardware on the SCSI bus. Refer to your hardware manual for additional information. SunOS 5.10 21 Sept 2005 cfgadm_scsi(1M)