Old 03-19-2009
if no multipathing software is active both controllers have access to the disks... you can mount them over c1t... and c2t1... for exampel.

you need to install SUNWsan + patches for multipathing support in solaris 8.
 

10 More Discussions You Might Find Interesting

1. Solaris

Thoughts/experiences of SAN attaching V880 to EMC SAN

Hi everyone, I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN? At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies

2. Red Hat

SAN Connected RedHat Server

I received 4 pre-loaded ready-to-go intel servers running RedHat Enterprise Linux 3 kernel version 2.6.9-22.18 build date june 29, 2006. They are equiped with QLOGIC 2400 dual-port HBA cards. I need to know what utilities or command-sets are available to check these cards out? How do I get their... (4 Replies)
Discussion started by: sallender
4 Replies

3. Solaris

Solaris9 - qlogic HBAs - luxadm reports "Found path to 0 HBA ports"

Hi All, I'm actually trying to configure a Qlogic HBA on a solaris9 connecting in a Brocade SAN. I installed Solaris9 and now trying to look at FC devices.. bash-2.05# luxadm -e port Found path to 0 HBA ports bash-2.05# luxadm probe No Network Array enclosures found in /dev/es... (7 Replies)
Discussion started by: ilan
7 Replies

4. Solaris

Backup and multi Path network

Dear All I have three site in multi city and have in three site ADSL connection with Fixed IP and three Connection leased line (VHSDSL) and and the primary connection it's VHSDSL and BAckup up connection ADSL So can i use IPMP in solaris OS 10 in three Site to have this Service in three Site... (0 Replies)
Discussion started by: Hosam
0 Replies

5. AIX

how to know if my aix have multi-path driver installed?

I have an aix server, it is not a VIO server or client. I need to check if it has multi-path driver installed, how to check it? (1 Reply)
Discussion started by: rainbow_bean
1 Replies

6. UNIX for Dummies Questions & Answers

a lot of Buffer I/O error on device connected to SAN

hi guys I have a server(x3650 M2) connected to a SAN...it takes a long time to boot with a lot errors like these any idea how to fix that? Suse Enterprise 10 SP3 update as soon as I disconnect the HBAs boots up normal and fast and no messages sdi:end_request: I/O error, dev sdh,... (0 Replies)
Discussion started by: kopper
0 Replies

7. UNIX for Advanced & Expert Users

Shell script to check the SAN dual path.

Hello, I would like to create a shell script which would check whether the hosts have SAN dual path or not. If yes, then I should get a success message, else should get a list of hosts on which SAN dual path is not working. Thanks.. (4 Replies)
Discussion started by: mahive
4 Replies

8. Solaris

SAN/Solaris: luxadm shows NOT CONNECTED

Hi, I have a question regarding HBA configuration. Here are the commands' output: # cfgadm -al | grep fc c1 fc-fabric connected unconfigured unknown c2 fc connected unconfigured unknown c5 ... (11 Replies)
Discussion started by: aixlover
11 Replies

9. Red Hat

How to find the SAN path?

Hi folks, How to identify the SAN is running in Single path or dual source path for linux servers. (2 Replies)
Discussion started by: gsiva
2 Replies

10. Red Hat

Physical path of NIC/HBA

How can I get the physical path i.e. slot#, port# etc. using a command on linux physical server? Looking for a command for mapping. thanks... (3 Replies)
Discussion started by: snchaudhari2
3 Replies
if_mpadm(1M)                                              System Administration Commands                                              if_mpadm(1M)

NAME
if_mpadm - change operational status of interfaces within a multipathing group SYNOPSIS
/usr/sbin/if_mpadm -d interface_name /usr/sbin/if_mpadm -r interface_name DESCRIPTION
Use the if_mpadm utility to change the operational status of interfaces that are part of an IP multipathing group. If the interface is operational, you can use if_mpadm -d to detach or off-line the interface. If the interface is off-lined, use if_mpadm -r to revert it to its original state. When a network interface is off-lined, all network access fails over to a different interface in the IP multipathing group. Any addresses that do not failover are brought down. Network access includes unicast, broadcast, and multicast for IPv4 and unicast and multicast for IPv6. Addresses marked with IFF_NOFAILOVER do not failover. They are marked down. After an interface is off-lined, the system will not use the interface for any outbound or inbound traffic, and the interface can be safely removed from the system without any loss of network access. The if_mpadm utility can be applied only to interfaces that are part of an IP multipathing group. OPTIONS
The if_mpadm utility supports the following options: -d interface_name Detach or off-line the interface specified by interface_name. -r interface_name Reattach or undo the previous detach or off-line operation on the interface specified by interface_name. Unless the -d option was used to detach or off-line the interface, this option will fail. EXAMPLES
Example 1: Detaching an Interface Use the following command to off-line or detach the interface. All network access will failover from hme0 to other interfaces in the same IP multipathing group. If no other interfaces are in the same group, the operation will fail. example% if_mpadm -d hme0 Example 2: Reattaching an Off-line Interface Use the following command to undo the previous operation. Network access will failback to hme0. example% if_mpdadm -r hme0 ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ |Interface Stability |Unstable | +-----------------------------+-----------------------------+ SEE ALSO
ifconfig(1M), in.mpathd(1M), attributes(5) DIAGNOSTICS
off-line failed as there is no other functional interface available in the multipathing group for failing over the network access. This message means that other interfaces in the group are failed over already or the multipathing configuration was not suitable for com- pleting a failover. off-line cannot be undone because multipathing configuration is not consistent across all the interfaces in the group. This message means that some interfaces in the IP multipathing group are not configured consistently with other interfaces in the group, for example, one of the interfaces in the group does not have an IFF_NOFAILOVER address. SunOS 5.10 3 Sep 2002 if_mpadm(1M)
All times are GMT -4. The time now is 09:52 AM.