Sponsored Content
Operating Systems HP-UX Set the Serial Number in HPUX? Post 302296618 by vbe on Wednesday 11th of March 2009 12:53:41 PM
Old 03-11-2009
Did you try to run print_manifest? (You never know...) Nice little box you got here...
addendum
I am saying that because of a serious issue I had before Christmas, where a mains chassis cabling burnt and there is no spare for that... The poor HP support engineer came with spare motherboard PSU etc ( but I told them...).
Since it was sensible production server I offered to strip down another server and because both of us were hungry and willing to go home (friday evening - not cool!), we opted to use the HBAs and internal disks and RAM of the burnt box and put them in the other.
Just tested now
Guess what, print_manifest gives me the serial number of the second although it had no more disks of its own...

Last edited by vbe; 03-11-2009 at 02:04 PM.. Reason: addendum
 

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Tape Serial Number

Hello Experts, I've got a shell script that makes the backup of the files that i want. I also have this script showing the amount of files backed up and in witch folders they are. It's only missing one thing. I got all the information beeing stored in a text file and all i've got to do is to... (6 Replies)
Discussion started by: jorge.ferreira
6 Replies

2. UNIX for Advanced & Expert Users

How to set baude rate of Serial port using setserial or other command

Hello, I am encountering problems when I use termios structure to set my baud rate of serial port. Pls give me a way by which I can set the same using a different command (1 Reply)
Discussion started by: zaheer031
1 Replies

3. UNIX Desktop Questions & Answers

HPUX 10.2 number pad

I have a keyboard that the number pad will not work. I cannot find the location of the configuration file to get it to work. I have to say, I have not tried another keyboard as my location is remote. Any suggestions? (0 Replies)
Discussion started by: esimeroth
0 Replies

4. Solaris

Display Serial Number

Hello, I am running Solaris 9 and I need to display the serial number of my machine. How can I do this? Here is my machine info: SunOS birch 5.9 Generic_118558-09 sun4u sparc SUNW,Sun-Fire-V240 Thank you, David (5 Replies)
Discussion started by: dkranes
5 Replies

5. Solaris

Serial number

Hi Solarizer ;) I have face the difficulties of gathering information about the serial number of sun machine. i think its can do so easy while the machine is just one or two. But i have to administrate hundreds of sun machine. Any body knows how to gather this information by the command ? ... (4 Replies)
Discussion started by: tpx99
4 Replies

6. Solaris

how to set the variales for serial port

Hi, I am working with Solaris 9 Sun Blade-100.I am doing some changes for serial port and by mistaken I changed the serial port /dev/term/a variables. So I need to make the changes fro /dev/term/a same as /dev/term/b. So please tell me how can I do that ?? (1 Reply)
Discussion started by: smartgupta
1 Replies

7. Solaris

Anyone know how to get Serial number with 1 command?

Solaris8 Anyone help? (27 Replies)
Discussion started by: frustrated1
27 Replies

8. UNIX for Advanced & Expert Users

How to set block size for CPIO in HPUX

Hi, One of our internal tool runs cpio command to archive certain files, but I receive an error as follows. CPIO Failure (operation would block) When i debugged, i assume that this an error due to block size.. My question are, How to find the block size in HP-UX?? How to set... (1 Reply)
Discussion started by: vj8436
1 Replies

9. Shell Programming and Scripting

Help about bind serial number

Hello folks. Please let me understand the bind serial number. I am confuse. 13011321 ---------- Post updated at 08:32 AM ---------- Previous update was at 07:55 AM ---------- Thanks problem is solved. (1 Reply)
Discussion started by: learnbash
1 Replies
vxrelocd(1M)															      vxrelocd(1M)

NAME
vxrelocd - monitor Veritas Volume Manager for failure events and relocate failed subdisks SYNOPSIS
/etc/vx/bin/vxrelocd [-o vxrecover_argument] [-O old_version] [-s save_max] [mail_address...] DESCRIPTION
The vxrelocd command monitors Veritas Volume Manager (VxVM) by analyzing the output of the vxnotify command, and waits for a failure. When a failure occurs, vxrelocd sends mail via mailx to root (by default) or to other specified users and relocates failed subdisks. After com- pleting the relocation, vxrelocd sends more mail indicating the status of each subdisk replacement. The vxrecover utility is then run on volumes with relocated subdisks to restore data. Mail is sent after vxrecover executes. OPTIONS
-o The -o option and its argument are passed directly to vxrecover if vxrecover is called. This allows specifying -o slow[=iodelay] to keep vxrecover from overloading a busy system during recovery. The default value for the delay is 250 milliseconds. -O Reverts back to an older version. Specifying -O VxVM_version directs vxrelocd to use the relocation scheme in that version. -s Before vxrelocd attempts a relocation, a snapshot of the current configuration is saved in /etc/vx/saveconfig.d. This option specifies the maximum number of configurations to keep for each diskgroup. The default is 32. Mail Notification By default, vxrelocd sends mail to root with information about a detected failure and the status of any relocation and recovery attempts. To send mail to other users, add the user login name to the vxrelocd startup line in the startup script /sbin/init.d/vxvm-recover, and reboot the system. For example, if the line appears as: nohup vxrelocd root & and you want mail also to be sent to user1 and user2, change the line to read: nohup vxrelocd root user1 user2 & Alternatively, you can kill the vxrelocd process and restart it as vxrelocd root mail_address, where mail_address is a user's login name. Do not kill the vxrelocd process while a relocation attempt is in progress. The mail notification that is sent when a failure is detected follows this format: Failures have been detected by the Veritas Volume Manager: failed disks: medianame ... failed plexes: plexname ... failed log plexes: plexname ... failing disks: medianame ... failed subdisks: subdiskname ... The Volume Manager will attempt to find spare disks, relocate failed subdisks and then recover the data in the failed plexes. The medianame list under failed disks specifies disks that appear to have completely failed; the medianame list under failing disks indi- cates a partial disk failure or a disk that is in the process of failing. When a disk has failed completely, the same medianame list appears under both failed disks and failing disks. The plexname list under failed plexes shows plexes that were detached due to I/O fail- ures that occurred while attempting to do I/O to subdisks they contain. The plexname list under failed log plexes indicates RAID-5 or DRL (dirty region logging) log plexes that have failed. The subdiskname list specifies subdisks in RAID-5 volumes that were detached due to I/O errors. Spare Space A disk can be marked as ``spare.'' This makes the disk available as a site for relocating failed subdisks. Disks that are marked as spares are not used for normal allocations unless you explicitly specify them. This ensures that there is a pool of spare space available for relocating failed subdisks and that this space does not get consumed by normal operations. Spare space is the first space used to relocate failed subdisks. However, if no spare space is available, or the available spare space is not suitable or sufficient, free space is also used except for those marked with the nohotuse flag. See the vxedit(1M) and vxdiskadm(1M) manual pages for more information on marking a disk as a spare or nohotuse. Nohotuse Space A disk can be marked as ``nohotuse.'' This excludes the disk from being used by vxrelocd, but it is still available as free space. See the vxedit(1M) and vxdiskadm(1M) manual pages for more information on marking a disk as a spare or nohotuse. Replacement Procedure After mail is sent, vxrelocd relocates failed subdisks (those listed in the subdisks list). This requires finding appropriate spare or free space in the same disk group as the failed subdisk. A disk is eligible as replacement space if it is a valid Veritas Volume Manager disk (VM disk) and contains enough space to hold the data contained in the failed subdisk. If no space is available on spare disks, the relocation uses free space that is not marked nohotuse. To determine which of the eligible disks to use, vxrelocd first tries the disk that is closest to the failed disk. The value of ``close- ness'' depends on the controller, target, and disk number of the failed disk. A disk on the same controller as the failed disk is closer than a disk on a different controller; a disk under the same target as the failed disk is closer than one under a different target. vxrelocd moves all subdisks from a failing drive to the same destination disk if possible. If no spare or free space is found, mail is sent explaining the disposition of volumes that had storage on the failed disk: Hot-relocation was not successful for subdisks on disk dm_name in volume v_name in disk group dg_name. No replacement was made and the disk is still unusable. The following volumes have storage on medianame: volumename ... These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If any non-RAID-5 volumes were made unusable due to the disk failure, the following message is included: The following volumes: volumename ... have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. These volumes must have their data restored. If any RAID-5 volumes were made unavailable due to the disk failure, the following message is included: The following RAID-5 volumes: volumename ... had storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. These RAID-5 volumes must have their data restored. If there is spare space available, a snapshot of the current configuration is saved in /etc/vx/saveconfig.d/dg_name.yymmdd_hhmmss.mpvsh before attempting a subdisk relocation. Relocation requires setting up a subdisk on the spare or free space not marked with nohotuse and using it to replace the failed subdisk. If this is successful, the vxrecover command runs in the background to recover the data in volumes that had storage on the disk. If the relocation fails, the following message is sent: Hot-relocation was not successful for subdisks on disk dm_name in volume v_name in disk group dg_name. No replacement was made and the disk is still unusable. If any volumes (RAID-5 or otherwise) become unusable due to the failure, the following message is included: The following volumes: volumename ... have data on dm_name but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. These volumes must have their data restored. If the relocation procedure was successful and recovery has begun, the following mail message is sent: Volume v_name Subdisk sd_name relocated to newsd_name, but not yet recovered. After recovery completes, a mail message is sent relaying the result of the recovery procedure. If the recovery is successful, the follow- ing message is included in the mail: Recovery complete for volume v_name in disk group dg_name. If the recovery was not successful, the following message is included in the mail: Failure recovering v_name in disk group dg_name. Disabling vxrelocd If you do not want automatic subdisk relocation, you can disable the hot-relocation feature by killing the relocation daemon, vxrelocd, and preventing it from restarting. However, do not kill the daemon while it is doing the relocation. To kill the daemon, run the command: ps -ef from the command line and find the two entries for vxrelocd. Execute the command: kill -9 PID1 PID2 (substituting PID1 and PID2 with the process IDs for the two vxrelocd processes). To prevent vxrelocd from being started again, you must comment out the line that starts up vxrelocd in the startup script /sbin/init.d/vxvm-recover. FILES
/sbin/init.d/vxvm-recover The startup file for vxrelocd. /etc/vx/saveconfig.d/dg_name.yymmdd_hhmmss.mpvsh File where vxrelocd saves a snapshot of the current configuration before performing a relocation. SEE ALSO
kill(1), mailx(1), ps(1), vxdiskadm(1M), vxedit(1M), vxintro(1M), vxnotify(1M), vxrecover(1M), vxsparecheck(1M), vxunreloc(1M) VxVM 5.0.31.1 24 Mar 2008 vxrelocd(1M)