Sponsored Content
Full Discussion: Migrating to new SAN switch
Operating Systems AIX Migrating to new SAN switch Post 302295730 by tdiYUZER on Monday 9th of March 2009 11:12:16 AM
Old 03-09-2009
Migrating to new SAN switch

Good morning,

I have 3 pSeries servers each with one internal boot VIOS and one boot-from-san VIOS... with numerous LPAR's running on top of them.

My question is: We are currently connecting to our IBM DS subsystem via a Cisco MDS 2GBPS SAN switch, we have recently purchased a Cisco MDS 4GBPS SAN switch and would like to migrate to it.

I have completed the migration of my WINTEL servers by simply shutting down the server, swinging over the cables, creating the new zone and powering the server back on.

I believe the AIX process is different however I am having trouble finding the correct proceedure. Can someone please help or point me in the correct direction.

Thanks.
 

10 More Discussions You Might Find Interesting

1. HP-UX

When migrating from HP-UX 11.0 to HP-UX 11.i

Hi to all, I am migrating HP-UX 11.0 to HP-UX 11.i, The following list are the components which i used in HP-UX 11.0, Whether I can use this same components in HP-UX 11.i or I should upgrade any of software version with respect to HP-UX 11.i. Oracle 8.1.7 Tuxedo 8.0 BEA Message queue... (0 Replies)
Discussion started by: sweta
0 Replies

2. HP-UX

Migrating from HP-UX 11 to HP-UX 11.i?

Hi, I want to Migrate my machine from HP-UX 11 to HP-UX 11.i, regarding this i would like to know the difference and the advances b/w these two. If anyone have cookbook HP-UX 11 to HP-UX 11.i, then provide the link to me. Thanks in Advance. Sarwan (3 Replies)
Discussion started by: sarwan
3 Replies

3. Solaris

Thoughts/experiences of SAN attaching V880 to EMC SAN

Hi everyone, I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN? At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies

4. Solaris

configure solaris 10 mail to relay email alerts from SAN switch

I want to be able to use an account on a solaris 10 server, eg root@myhost to act as a relay to forward mail to my domain account me@mycompany.com The reason for this is to configure root@myhost as a mail relay on Brocade SAN switches - so that when a port goes bad i get an email alert.... (0 Replies)
Discussion started by: wibidee
0 Replies

5. Shell Programming and Scripting

how to access console of a switch having rj45 on switch side to db 9 female on pc side console cable

hi, how to access console of a switch having rj45 on switch side to db 9 female on pc side console cable which needs to be connected to one console server having rj11 on its side and db 9 female on other end.i.e. on switch side,console cable has rj45 and db 9 pin female connector on other side of... (1 Reply)
Discussion started by: pankajd
1 Replies

6. Solaris

Find Brocade SAN switch’s IP in Sun server?

We have a Sun M5000 connecting to a Brocade SAN switch. I don't know the IP of the Brocade switch and don't want to use its serial port to get the info. How can I find the IP of the Brocade switch under Solaris 10? Snoop is not supported by Solaris multipathing. What other tools can I use to find... (6 Replies)
Discussion started by: aixlover
6 Replies

7. AIX

IBM SAN TO SAN Mirroring

Has anyone tried SAN to SAN mirroring on IBM DS SAN Storage. DS5020 mentions Enhanced Remote Mirror to multi-LUN applications I wonder if Oracle High availibility can be setup using Remote Mirror option of SAN ? (1 Reply)
Discussion started by: filosophizer
1 Replies

8. AIX

AIX - FC Switch migration, SAN Migration question!

I'm New to AIX / VIOS We're doing a FC switch cutover on an ibm device, connected via SAN. How do I tell if one path to my remote disk is lost? (aix lvm) How do I tell when my link is down on my HBA port? Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies

9. UNIX for Beginners Questions & Answers

Migrating to UNIX

I am looking for a stable, reliable system to replace my current Windows systems in the home. These are simple systems that I purchased from the local Big Box store. I have heard many good things about Unix and it's various children and it sounds like a good option to me. I have worked... (2 Replies)
Discussion started by: donschurter
2 Replies

10. Filesystems, Disks and Memory

Faster way: SAN hd to SAN hd copying

hi! i got a rhel 6.3 host that already have an xfs filesystem mounted from a SAN (let's call it SAN-1) whose size is 9TB. i will be receiving another SAN (let's call it SAN-2) storage of 15TB size. this new addition is physically on another SAN storage. SAN-1 is on a Pillar storage while the new... (6 Replies)
Discussion started by: rino19ny
6 Replies
norewind_close_disabled(5)					File Formats Manual					norewind_close_disabled(5)

NAME
norewind_close_disabled - determine whether access to tape device special files without the no-rewind-on-close option is allowed VALUES
Default Allowed values DESCRIPTION
Note: this tunable was named in releases prior to HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on, the tape driver will fail any open on a tape device special file that does not have the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued accidentally from this system on close, possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. EXAMPLES
Query the current value of the tunable: Set the value of the tunable to To save the value of the tunable across reboots: WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters norewind_close_disabled(5)
All times are GMT -4. The time now is 05:09 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy