Sponsored Content
Operating Systems Solaris Question regarding Zone Migration Post 302292136 by blicki on Friday 27th of February 2009 04:32:08 AM
Old 02-27-2009
Hey em23:

This will only work for sure, if you do not change the Solaris Release. After some heavy troubles migrating sol zones from Solaris 10 U2 or U4 to current, we decided to reinstall software in a newly created zone. I dunno how "standard" software, like ProFTPD and SSL, reacts on this...
 

9 More Discussions You Might Find Interesting

1. Solaris

Veritas Storage Question (Data Migration)

Using Solaris 10 with Veritas Storage Foundation running. I want to copy all contents from DISKA LUN1 to DISKB LUN2. What would be the command syntax to do this? (0 Replies)
Discussion started by: soupbone38
0 Replies

2. Solaris

Some Question's about Zone

Hi all, i am new learner in Zoning and virtualization Technology and i have some question's about it i create zone using this step zonecfg -z app-apache create set zonepath=/zone_adm/app-apache add net set address=192.168.1.250 set physical=bge0 end set autoboot=true verify commit... (13 Replies)
Discussion started by: coxmanchester
13 Replies

3. Solaris

Zone failes to boot due to mount issue, dir exists in zone.

I have two physical servers, with zones that mount local storage. We were using "raw device" in the zonecfg to point to a metadevice on the global zone (it was not mounted in the global zone at any point). It failed to mount on every boot because the directory existed in the zone. I... (6 Replies)
Discussion started by: BG_JrAdmin
6 Replies

4. Solaris

Solaris Zone migration which are clustered

Hello Admins... How can we migrate a solaris 10 zone which is clustered...?? We have sun cluster 3.2 in our environment. And this is 2 -node cluster Let me know guys... Thanks. (0 Replies)
Discussion started by: snchaudhari2
0 Replies

5. Solaris

Zone ipf question

Hello, I was wondering, if your setting ipf filter rules on a Solaris 10 server with one or more full root zones. Where do you set it? I know that the place to set the rules is here; /etc/ipf/ipf.conf. Do I set it in each zone and the global? Or should I just set the rules at the global? ... (7 Replies)
Discussion started by: bitlord
7 Replies

6. Solaris

Zone Cluster Question

I have a question about losing a node in a zone cluster. Hopefully I can explain enough for someone to answer. Let's say I have a zone cluster spread over 3 physical nodes. If Node1 crashes, would I be correct in assuming I would lose all zones on Node1? If I lost Node1 below, would I lose... (4 Replies)
Discussion started by: MasonJ
4 Replies

7. UNIX for Advanced & Expert Users

Solaris 10: I forgot to detach a zone before zpool export. Uninstall zone?

Dear all, recently, I migrated a solaris zone from one host to another. The zone was inside of a zpool. The zpool cotains two volumes. I did the following: host1: $ zlogin zone1 shutdown -y -g0 -i0 #Zone status changes from running to installed $ zpool export zone1 host2: $ zpool... (2 Replies)
Discussion started by: custos
2 Replies

8. HP-UX

SAN Migration question

Hi, I am very new to HP-UX, and we're going to be doing a SAN migration. We're going to take down the machine, and zone it to the new SAN. My question is, will the device names change and will that interfere with the LVM? If the new disks come in with different device names, how would I... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

9. AIX

AIX - FC Switch migration, SAN Migration question!

I'm New to AIX / VIOS We're doing a FC switch cutover on an ibm device, connected via SAN. How do I tell if one path to my remote disk is lost? (aix lvm) How do I tell when my link is down on my HBA port? Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies
tzmon(7d)							      Devices								 tzmon(7d)

NAME
tzmon - ACPI Thermal Zone Monitor DESCRIPTION
The tzmon is a pseudo driver that serves as an ACPI thermal zone monitor. Thermal zones are logical regions within a computer system for which ACPI performs temperature monitoring and control functions. The number of thermal zones on a system with ACPI support varies. For example, some systems may have one or more thermal zones, while others may have none. See the Advanced Configuration and Power Interface Specification, (ACPI) Version 3.0A. for more details. The tzmon handles thermal Zone events from ACPI and polls the temperature for each zone exposed by the ACPI implementation. If threshold temperatures are reached, tzmon takes appropriate action. For example, if the temperature is sufficiently high and the ACPI implementation supports it, tzmon initiates system shutdown. Note that by default, system temperature control functions are usually performed by the BIOS and may supersede tzmon functions, depending on the BIOS implementation. Also, many ACPI implementations expose no thermal zones and in these cases, tzmon performs no functions. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWckr | +-----------------------------+-----------------------------+ |Architecture |x86/x64 only | +-----------------------------+-----------------------------+ |Interface stability |Private | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5) Advanced Configuration and Power Interface Specification, (ACPI), Version 3.0A. SunOS 5.11 31 Oct 2006 tzmon(7d)
All times are GMT -4. The time now is 12:42 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.